EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Electrochemical biosensing platform based on AuNWs/rGO-CMC-PEDOT:PSS composite for the detection of superoxide anion released from living cells

Renjun Jiang, Jiaojiao Liu, Xiaoqiang Liu, Jadranka Travas Sejdic

Biosensors and Bioelectronics · 2024-06 · 254 · 116228

DOI: 10.1016/j.bios.2024.116228 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-06. Verfasst von Renjun Jiang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Henan Joint International Research Laboratory of Environmental Pollution Control Materials, College of Chemical and Molecular Sciences, Henan Univers…. Hauptthemen laut MEDLINE: Biosensing Techniques, Graphite. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Detection of superoxide anion (O2·-) levels holds significant importance for the diagnosis and even clinical treatments of oxidative stress-related diseases. Herein, we prepared a composite electrode material to encapsulate copper-zinc superoxide dismutase (SOD1) for biosensing of O2·-. The sensing material consists of gold nanowires (AuNWs), reduced graphene oxide (rGO), carboxymethyl cellulose (CMC) and PEDOT:PSS. CMC provides abundant -COOH to bind SOD1, with a high adsorption coverage of 1.499 × 10-9 mol cm-2 on the sensor surface. rGO and PEDOT endow the composite with significant conductivity, whereas PSS has antifouling capability. Moreover, AuNWs exhibit excellent electrical conductivity and a high aspect ratio, which promotes electron transfer, and ultimately enhances the catalytic performance of the enzyme. Meanwhile, SOD1(Cu2+) catalyzes the dismutation of O2·- to O2 and H2O2, and H2O2 is then electrochemically oxidized to generate amperometric signals for determination of O2·-. The sensor demonstrates outstanding detection performance for O2·- with a low detection limit of 2.52 nM, and two dynamic ranges (14.30 nM-1.34 μM and 1.34 μM-42.97 μM) with corresponding sensitivity of 0.479 and 0.052 μA μM-1cm-2, respectively. Additionally, the calculated apparent Michaelis constant (Kmapp) of 1.804 μM for SOD1 demonstrates the outstanding catalytic activity and the surface-immobilized enzyme's substrate affinity. Furthermore, the sensor shows the capability to dynamically detect the level of O2·- released from living HepG2 cells. This study provides an inovative design to obtain a biocompatible electrochemical sensing platform with plenty of immobilization sites for biomolecules, large surface area, high conductivity and flexibility.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesGraphiteSuperoxidesCarboxymethylcellulose SodiumHydrogen PeroxideSuperoxide Dismutase-1Superoxide DismutaseElectrochemical Techniques

Stichwörter der Autor:innen

Antifouling capabilityComposite electrode materialCopper-zinc superoxide dismutaseElectrochemical biosensorSuperoxide anion (O(2)(·-))

Substanzen

Superoxidesgraphene oxideCarboxymethylcellulose SodiumHydrogen PeroxideSuperoxide Dismutase-1GraphiteSuperoxide Dismutase

Autor:innen und Institutionen

  • Henan Joint International Research Laboratory of Environmental Pollution Control Materials, College of Chemical and Molecular Sciences, Henan University, Kaifeng, 475004, China.
  • Henan Joint International Research Laboratory of Environmental Pollution Control Materials, College of Chemical and Molecular Sciences, Henan University, Kaifeng, 475004, China; State Key Laboratory of Antiviral Drugs,…
  • Centre for Innovative Materials for Health, School of Chemical Sciences, The University of Auckland - Waipapa Taumata Rau, 23 Symonds Street, Auckland, 1023, New Zealand; MacDiarmid Institute for Advanced Materials and…

Zitieren

APA

Jiang, R., Liu, J., Liu, X., & Travas Sejdic, J. (2024). Electrochemical biosensing platform based on AuNWs/rGO-CMC-PEDOT:PSS composite for the detection of superoxide anion released from living cells. Biosensors and Bioelectronics, 254, 116228. https://doi.org/10.1016/j.bios.2024.116228

Vancouver

Jiang R, Liu J, Liu X, Travas Sejdic J. Electrochemical biosensing platform based on AuNWs/rGO-CMC-PEDOT:PSS composite for the detection of superoxide anion released from living cells. Biosensors and Bioelectronics. 2024;254:116228. doi:10.1016/j.bios.2024.116228

BibTeX
@article{Jiang2024,
  author = {Jiang, Renjun and Liu, Jiaojiao and Liu, Xiaoqiang and Travas Sejdic, Jadranka},
  title = {Electrochemical biosensing platform based on AuNWs/rGO-CMC-PEDOT:PSS composite for the detection of superoxide anion released from living cells},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  volume = {254},
  pages = {116228},
  doi = {10.1016/j.bios.2024.116228}
}
Kostenlos starten →