EUVIMEDEUVIMED entdecken
Crossref

Flexible microfluidic co-recognition coupled with magnetic enrichment and silent SERS sensing for simultaneous analysis of bacteria in food

Bingyang Huo, Ling Xia, Yuling Hu, Gongke Li

Biosensors and Bioelectronics · 2024

DOI: 10.1016/j.bios.2024.116227 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024. Verfasst von Bingyang Huo und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry, Sun Yat-sen University, Guangzhou, 510006, China. Hauptthemen laut MEDLINE: Metal Nanoparticles, Biosensing Techniques. Die Arbeit wurde bisher 44-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Food safety represents a critical global public health issue, with safety challenges posed by foodborne pathogens garnering extensive attention. Therefore, we introduce a co-recognition, enrichment and sensing (CES) all-in-one strategy for analysis of bacteria with low background and high specificity. This method employs antimicrobial peptide (AMP) functionalized magnetic nanoparticles (MNPs) to enrich bacteria and uses aptamer@Au@PBA (KxMFe(CN)6 (M = Pb and Ni)) NPs as silent SERS tags. When both S. aureus and E. coli O157:H7 are present, the silent SERS probes could specifically label the target bacteria, forming a sandwich-like structure. This binding induces silent Raman shifts (2139 cm-1 and 2197 cm-1), enabling quantification of two bacteria. Coupling with the modular flexible microfluidics and magnetic control slider device, this platform facilitates rapid switching between magnetic loading and elution. The CES SERS method demonstrated linear relationships for both S. aureus and E. coli O157:H7 at 50-1600 cfu mL-1, with detection limits of 14 and 18 cfu mL-1, respectively. The method achieved recovery rates of 85.6-112% and relative standard deviations of 1.5-8.6%. Validation using the ELISA method revealed relative errors between -7.5 and 4.3%. The CES approach has potential applications in food safety, environmental monitoring, and biomedical diagnosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Metal NanoparticlesBiosensing TechniquesStaphylococcus aureusEscherichia coliMicrofluidicsBacteriaMagnetic PhenomenaSpectrum Analysis, RamanGold

Stichwörter der Autor:innen

BacteriaFlexible microfluidic co-recognitionMagnetic enrichmentSilent SERS sensingSimultaneous analysis

Substanzen

Gold

Autor:innen und Institutionen

  • School of Chemistry, Sun Yat-sen University, Guangzhou, 510006, China.
  • School of Chemistry, Sun Yat-sen University, Guangzhou, 510006, China. Electronic address: cesgkl@mail.sysu.edu.cn.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Huo, B., Xia, L., Hu, Y., & Li, G. (2024). Flexible microfluidic co-recognition coupled with magnetic enrichment and silent SERS sensing for simultaneous analysis of bacteria in food. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2024.116227

Vancouver

Huo B, Xia L, Hu Y, Li G. Flexible microfluidic co-recognition coupled with magnetic enrichment and silent SERS sensing for simultaneous analysis of bacteria in food. Biosensors and Bioelectronics. 2024. doi:10.1016/j.bios.2024.116227

BibTeX
@article{Huo2024,
  author = {Huo, Bingyang and Xia, Ling and Hu, Yuling and Li, Gongke},
  title = {Flexible microfluidic co-recognition coupled with magnetic enrichment and silent SERS sensing for simultaneous analysis of bacteria in food},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  doi = {10.1016/j.bios.2024.116227}
}
Kostenlos starten →