EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Electrochemical Pixels: Semi-open electrochemical cells with a vertically stacked design

Marc Clua Estivill, Jhonattan F Baez, Pascal Blondeau, Francisco J Andrade

Biosensors and Bioelectronics · 2024-02 · 246 · 115877

DOI: 10.1016/j.bios.2023.115877 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-02. Verfasst von Marc Clua Estivill und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Analytical and Organic Chemistry, Universitat Rovira i Virgili, 43007, Tarragona, Spain. Hauptthemen laut MEDLINE: Biosensing Techniques. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A novel electrochemical cell design in a vertically stacked configuration is presented. Through a layered structure using a top macroporous working electrode, a polyelectrolyte, and a bottom metallic conductor a standalone electrochemical cell with an internal reference electrode is built. This sensor allows monitoring an electrochemical property of an external solution with only one electrode in direct contact with the sample. Using paper-based platinum electrode for the porous top electrode and Nafion as polyelectrolyte material, the self-powered detection of hydrogen peroxide is performed. The system can be operated in multiple modes. In a capacitive way, the open circuit potential is measured. Alternatively, in a self-powered current mode, the system emulates a fuel cell. Additionally, a potential-current switched mode is also demonstrated. Because of this unique design and operational features this sensor is considered as an electrochemical pixel. To further demonstrate the advantages of this device, the detection of glucose is performed by building an array of sensors using a single back (reference) electrode and multiple working electrodes. These results lay the groundwork for the development of a new generation of simple and low cost biochemical sensors and electrochemical sensing arrays.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesPolyelectrolytesElectrodesHydrogen PeroxidePorosityElectrochemical Techniques

Stichwörter der Autor:innen

Capacitive biosensorsMixed potentialPolyelectrolyte membranesPseudo-capacitorsSolid-state sensors

Substanzen

PolyelectrolytesHydrogen Peroxide

Autor:innen und Institutionen

  • Department of Analytical and Organic Chemistry, Universitat Rovira i Virgili, 43007, Tarragona, Spain.
  • Department of Analytical and Organic Chemistry, Universitat Rovira i Virgili, 43007, Tarragona, Spain. Electronic address: franciscojavier.andrade@urv.cat.

Zitieren

APA

Clua Estivill, M., Baez, J. F., Blondeau, P., & Andrade, F. J. (2024). Electrochemical Pixels: Semi-open electrochemical cells with a vertically stacked design. Biosensors and Bioelectronics, 246, 115877. https://doi.org/10.1016/j.bios.2023.115877

Vancouver

Clua Estivill M, Baez JF, Blondeau P, Andrade FJ. Electrochemical Pixels: Semi-open electrochemical cells with a vertically stacked design. Biosensors and Bioelectronics. 2024;246:115877. doi:10.1016/j.bios.2023.115877

BibTeX
@article{CluaEstivill2024,
  author = {Clua Estivill, Marc and Baez, Jhonattan F and Blondeau, Pascal and Andrade, Francisco J},
  title = {Electrochemical Pixels: Semi-open electrochemical cells with a vertically stacked design},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  volume = {246},
  pages = {115877},
  doi = {10.1016/j.bios.2023.115877}
}
Kostenlos starten →