Development of a peptide microarray-based metal-enhanced fluorescence assay for ultrasensitive detection of multiple matrix metalloproteinase activities by using a gold nanorod-polymer substrate
Biosensors and Bioelectronics · 2024
DOI: 10.1016/j.bios.2023.115871 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024. Verfasst von Minghong Jian und 5 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, PR Chi…. Hauptthemen laut MEDLINE: Biosensing Techniques, Neoplasms, Nanotubes. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 53 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Jilin Provincial Science and Technology Department.
Abstract (Originalsprache)
Matrix metalloproteinases (MMPs) are attractive biomarkers for cancer diagnosis and treatment, while it is still a challenge to precise analysis of MMP activities owing to their very low abundance in the biological samples, especially at the early stages of tumors. Herein, a peptide microarray-based metal-enhanced fluorescence assay (PMMEFA) is proposed to simultaneously detect MMP-1, -2, -3, -7, -9, and -13 activities. The assay involves immobilization of Förster resonance energy transfer dye pair decorated peptides (FRET-peptides) on a poly(glycidyl methacrylate-co-2-hydroxyethyl methacrylate) coated gold nanorod modified glass slide (GNR@P(GMA-HEMA)). To fabricate the GNR@P(GMA-HEMA) slide, GNRs are self-assembled onto an aminated glass slide, and a polymer brush (P(GMA-HEMA)) is grown through a surface-initiated atom transfer radical polymerization reaction (SI-ATRP). Upon the addition of MMPs, the FRET pairs are broken due to the specific cleavage of FRET-peptides by enzymes, resulting in the recovery of fluorescence signals and further enhancement by the MEF of GNRs. The fluorescence recovery degree provides a direct indicator for MMP activity. The PMMEFA exhibits excellent sensitivity, which enables to detect MMP-1, -2, -3, -7, -9, and -13 activities, with low limits of detection (LODs) of 1.7 fg mL-1, 0.3 fg mL-1, 2.0 fg mL-1, 1.8 fg mL-1, 2.2 fg mL-1 and 14.0 fg mL-1, respectively. To substantiate the practicability of PMMEFA, MMP activities were measured in a range of matrices, encompassing cell culture medium, serum, and tumor tissue homogenate, and MMP activities can be detected only in 0.15 μL serum and 0.025 mg tumor tissue.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, PR China.
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, PR China; School of Applied Chemistry and Engineering, University of Science…
Förderung
- National Natural Science Foundation of China
- Jilin Provincial Science and Technology Department
Zitieren
APA
Jian, M., Sun, X., Zhang, H., Li, X., Li, S., & Wang, Z. (2024). Development of a peptide microarray-based metal-enhanced fluorescence assay for ultrasensitive detection of multiple matrix metalloproteinase activities by using a gold nanorod-polymer substrate. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2023.115871
Vancouver
Jian M, Sun X, Zhang H, Li X, Li S, Wang Z. Development of a peptide microarray-based metal-enhanced fluorescence assay for ultrasensitive detection of multiple matrix metalloproteinase activities by using a gold nanorod-polymer substrate. Biosensors and Bioelectronics. 2024. doi:10.1016/j.bios.2023.115871
BibTeX
@article{Jian2024,
author = {Jian, Minghong and Sun, Xudong and Zhang, Hua and Li, Xiaotong and Li, Shasha and Wang, Zhenxin},
title = {Development of a peptide microarray-based metal-enhanced fluorescence assay for ultrasensitive detection of multiple matrix metalloproteinase activities by using a gold nanorod-polymer substrate},
journal = {Biosensors and Bioelectronics},
year = {2024},
doi = {10.1016/j.bios.2023.115871}
}
EUVIMED