Implantable anti-biofouling biosupercapacitor with high energy performance
Biosensors and Bioelectronics · 2024-01 · 243 · 115757
DOI: 10.1016/j.bios.2023.115757 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-01. Verfasst von Taegyu Park und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronic Engineering, College of Engineering, Hanyang University, Seoul, 04763, South Korea. Hauptthemen laut MEDLINE: Biofouling, Biosensing Techniques, Body Fluids, Nanotubes, Carbon. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: Hanyang University, National Research Foundation of Korea.
Abstract (Originalsprache)
Biofluidic open-type supercapacitors offer significant advantages over batteries in implantable electronics. However, poor energy storage in bioelectrolytes and performance degradation owing to electrode biofouling remain challenges and hamper their implementation. In this study, we present a flexible polydopamine (PDA)-infiltrated carbon nanotube (CNT) yarn (PDA/CNT) supercapacitor with high performance in biofluids, encapsulated by a hydrogel-barrier circular knit that provides anti-biofouling protection. Infiltration of the biopolymer PDA provide a hydrophilic coating to obtain a hydrophobic CNT electrode under aqueous conditions and an energy density 250-fold higher than that of the pristine CNT in the biofluid. The PDA/CNT supercapacitor exhibited remarkable energy performance in biological fluids in terms of the maximum areal capacitance (503.91 mF cm-2), energy density (274 μWh/cm2), and power density (25.52 mW cm-2). Moreover, it demonstrated negligible capacitance loss after 10,000 repeated charge/discharge cycles and bending tests. To prevent biofouling, the PDA/CNT electrode was encapsulated in an agarose-coated circular knit that allows free movement of the electrolyte. Notably, implanting an encapsulated PDA/CNT supercapacitor into the abdominal cavity of rat resulted in stable in vivo energy storage performance without biofouling for 21 d, and the charged supercapacitor was used successfully to power a light-emitting diode in vivo.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Electronic Engineering, College of Engineering, Hanyang University, Seoul, 04763, South Korea.
- Department of Pharmacology, College of Medicine, Hanyang University, Seoul 04736, South Korea.
- Department of Medical and Digital Engineering, College of Engineering, Hanyang University, Seoul 04736, South Korea.
- Department of Electronic Engineering, College of Engineering, Hanyang University, Seoul, 04763, South Korea; Department of Energy and Materials Engineering, College of Engineering, Dongguk University, Seoul, 04620, Sout…
- Department of Energy and Materials Engineering, College of Engineering, Dongguk University, Seoul, 04620, South Korea.
- Department of Pharmacology, College of Medicine, Hanyang University, Seoul 04736, South Korea; Department of Medical and Digital Engineering, College of Engineering, Hanyang University, Seoul 04736, South Korea. Electro…
Förderung
- Hanyang University
- National Research Foundation of Korea
Zitieren
APA
Park, T., Lee, D. Y., Ahn, B. J., Kim, M., Bok, J., Kang, J. S., Lee, J. M., Choi, C., & Jang, Y. (2024). Implantable anti-biofouling biosupercapacitor with high energy performance. Biosensors and Bioelectronics, 243, 115757. https://doi.org/10.1016/j.bios.2023.115757
Vancouver
Park T, Lee DY, Ahn BJ, Kim M, Bok J, Kang JS, et al. Implantable anti-biofouling biosupercapacitor with high energy performance. Biosensors and Bioelectronics. 2024;243:115757. doi:10.1016/j.bios.2023.115757
BibTeX
@article{Park2024,
author = {Park, Taegyu and Lee, Dong Yeop and Ahn, Bum Ju and Kim, Minwoo and Bok, Junsoo and Kang, Ju-Seop and Lee, Jae Myeong and Choi, Changsoon and Jang, Yongwoo},
title = {Implantable anti-biofouling biosupercapacitor with high energy performance},
journal = {Biosensors and Bioelectronics},
year = {2024},
volume = {243},
pages = {115757},
doi = {10.1016/j.bios.2023.115757}
}
EUVIMED