Methods gold standard in clinic millifluidics multiplexed extended gate field-effect transistor biosensor with gold nanoantennae as signal amplifiers
Biosensors and Bioelectronics · 2023-12 · 241 · 115701
DOI: 10.1016/j.bios.2023.115701 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2023-12. Verfasst von Željko Janićijević und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01328, Dresden, Germany. Hauptthemen laut MEDLINE: Metal Nanoparticles, Biosensing Techniques. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 88 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
We present a portable multiplexed biosensor platform based on the extended gate field-effect transistor and demonstrate its amplified response thanks to gold nanoparticle-based bioconjugates introduced as a part of the immunoassay. The platform comprises a disposable chip hosting an array of 32 extended gate electrodes, a readout module based on a single transistor operating in constant charge mode, and a multiplexer to scan sensing electrodes one-by-one. Although employing only off-the-shelf electronic components, our platform achieves sensitivities comparable to fully customized nanofabricated potentiometric sensors. In particular, it reaches a detection limit of 0.2 fM for the pure molecular assay when sensing horseradish peroxidase-linked secondary antibody (∼0.4 nM reached by standard microplate methods). Furthermore, with the gold nanoparticle bioconjugation format, we demonstrate ca. 5-fold amplification of the potentiometric response compared to a pure molecular assay, at the detection limit of 13.3 fM. Finally, we elaborate on the mechanism of this amplification and propose that nanoparticle-mediated disruption of the diffusion barrier layer is the main contributor to the potentiometric signal enhancement. These results show the great potential of our portable, sensitive, and cost-efficient biosensor for multidimensional diagnostics in the clinical and laboratory settings, including e.g., serological tests or pathogen screening.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01328, Dresden, Germany.
- Institute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01328, Dresden, Germany; Faculty of Chemistry and Geosciences, Institute of Chemistry, Vilnius University,…
- Institute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01328, Dresden, Germany. Electronic address: l.baraban@hzdr.de.
Zitieren
APA
Janićijević, Ž., Nguyen-Le, T. A., Alsadig, A., Cela, I., Žilėnaite, R., Tonmoy, T. H., Kubeil, M., Bachmann, M., & Baraban, L. (2023). Methods gold standard in clinic millifluidics multiplexed extended gate field-effect transistor biosensor with gold nanoantennae as signal amplifiers. Biosensors and Bioelectronics, 241, 115701. https://doi.org/10.1016/j.bios.2023.115701
Vancouver
Janićijević Ž, Nguyen-Le TA, Alsadig A, Cela I, Žilėnaite R, Tonmoy TH, et al. Methods gold standard in clinic millifluidics multiplexed extended gate field-effect transistor biosensor with gold nanoantennae as signal amplifiers. Biosensors and Bioelectronics. 2023;241:115701. doi:10.1016/j.bios.2023.115701
BibTeX
@article{Janiijevi2023,
author = {Janićijević, Željko and Nguyen-Le, Trang-Anh and Alsadig, Ahmed and Cela, Isli and Žilėnaite, Rugilė and Tonmoy, Taufhik Hossain and Kubeil, Manja and Bachmann, Michael and Baraban, Larysa},
title = {Methods gold standard in clinic millifluidics multiplexed extended gate field-effect transistor biosensor with gold nanoantennae as signal amplifiers},
journal = {Biosensors and Bioelectronics},
year = {2023},
volume = {241},
pages = {115701},
doi = {10.1016/j.bios.2023.115701}
}
EUVIMED