EUVIMEDEUVIMED entdecken
Crossref

Hypochlorite activatable ratiometric fluorescent probe based on endoplasmic reticulum stress for imaging of atherosclerosis

Lijuan Gui, Jun Yan, Junyuan Zhao, Shiya Wang, Yingying Ji, Ji Liu, Jinsheng Wu, Kang Yuan, Heng Liu, Dawei Deng, Zhenwei Yuan

Biosensors and Bioelectronics · 2023-11 · 240 · 115660

DOI: 10.1016/j.bios.2023.115660 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2023-11. Verfasst von Lijuan Gui und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, School of Engineering, China Pharmaceutical University, 639 Longmian Road, Jiangning District, Nanjing, 210009,…. Hauptthemen laut MEDLINE: Biosensing Techniques, Atherosclerosis. Die Arbeit wurde bisher 60-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Fundamental Research Funds for the Central Universities, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Endoplasmic reticulum (ER) stress can induce reactive oxygen (ROS) generation which is directly associated with the emergence of atherosclerosis. Foam cells could promote atherogenesis by inducing ER stress. To understand hypochlorite (ClO-) levels in foam cells under ER stress, novel ER-targeted ClO- activatable ratiometric fluorescence probes Rx-NE and Rx-NCE were designed using a classical rhodamine dye and coumarin dye bridge moiety as the fluorescent skeleton. Both Rx-NE and Rx-NCE demonstrated ratiometric detection capabilities for ClO-, with Rx-NCE showing better sensitivity compared to Rx-NE. The probe Rx-NCE could detect the upregulation of ClO- in foam cells under ER stress and clearly outline delineation of the boundary of atherosclerotic plaques by dual-color imaging. Importantly, the hypochlorite-activated ratiometric probe Rx-NCE had been innovatively applied to the distinction of atherosclerotic blood vessels in atherosclerosis-bearing transgenic (tg) (flk1: eGFP) zebrafish. The probe Rx-NCE is of significant value for investigating the pathological role of ER stress and atherosclerotic diseases, as well as offering new insights into the identification of atherosclerosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesAtherosclerosisAnimalsFluorescent DyesHypochlorous AcidZebrafishEndoplasmic Reticulum Stress

Stichwörter der Autor:innen

AtherosclerosisEndoplasmic reticulum stressFoam cellsHypochlorite-activatableRatiometric fluorescence probe

Substanzen

Fluorescent DyesHypochlorous Acid

Autor:innen und Institutionen

  • Department of Biomedical Engineering, School of Engineering, China Pharmaceutical University, 639 Longmian Road, Jiangning District, Nanjing, 210009, China.
  • Department of Radiotherapy, The First Affiliated Hospital of Hainan Medical University, Hainan Medical University, Haikou, 571199, China.
  • Department of Radiotherapy, The First Affiliated Hospital of Hainan Medical University, Hainan Medical University, Haikou, 571199, China. Electronic address: liuheng11b@hubu.edu.cn.
  • Department of Biomedical Engineering, School of Engineering, China Pharmaceutical University, 639 Longmian Road, Jiangning District, Nanjing, 210009, China. Electronic address: dengdawei@cpu.edu.cn.
  • Department of Biomedical Engineering, School of Engineering, China Pharmaceutical University, 639 Longmian Road, Jiangning District, Nanjing, 210009, China. Electronic address: yuanzhenwei@cpu.edu.cn.

Förderung

  • Fundamental Research Funds for the Central Universities
  • National Natural Science Foundation of China

Zitieren

APA

Gui, L., Yan, J., Zhao, J., Wang, S., Ji, Y., Liu, J., Wu, J., Yuan, K., Liu, H., Deng, D., & Yuan, Z. (2023). Hypochlorite activatable ratiometric fluorescent probe based on endoplasmic reticulum stress for imaging of atherosclerosis. Biosensors and Bioelectronics, 240, 115660. https://doi.org/10.1016/j.bios.2023.115660

Vancouver

Gui L, Yan J, Zhao J, Wang S, Ji Y, Liu J, et al. Hypochlorite activatable ratiometric fluorescent probe based on endoplasmic reticulum stress for imaging of atherosclerosis. Biosensors and Bioelectronics. 2023;240:115660. doi:10.1016/j.bios.2023.115660

BibTeX
@article{Gui2023,
  author = {Gui, Lijuan and Yan, Jun and Zhao, Junyuan and Wang, Shiya and Ji, Yingying and Liu, Ji and Wu, Jinsheng and Yuan, Kang and Liu, Heng and Deng, Dawei and Yuan, Zhenwei},
  title = {Hypochlorite activatable ratiometric fluorescent probe based on endoplasmic reticulum stress for imaging of atherosclerosis},
  journal = {Biosensors and Bioelectronics},
  year = {2023},
  volume = {240},
  pages = {115660},
  doi = {10.1016/j.bios.2023.115660}
}
Kostenlos starten →