Biosensor development for low-level acetaldehyde gas detection using mesoporous carbon electrode printed on a porous polyimide film
Biosensors and Bioelectronics · 2023-10 · 238 · 115555
DOI: 10.1016/j.bios.2023.115555 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2023-10. Verfasst von Isao Shitanda und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba, 278-8510, Japan…. Hauptthemen laut MEDLINE: Carbon, Biosensing Techniques. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 39 Literaturangaben.
Abstract (Originalsprache)
Acetaldehyde, which is an intermediate product of alcohol metabolism, is known to induce symptoms, including alcohol flushing, vomiting, and headaches in humans. Therefore, real-time monitoring of acetaldehyde levels is crucial to mitigating these health issues. However, current methods for detecting low-concentration gases necessitate the use of complex measurement equipment. In this study, we developed a low-cost, low-detection-limit, enzyme-based electrochemical biosensor for acetaldehyde gas detection that does not require sophisticated equipment. The sensor was constructed by screen-printing electrodes onto a porous polyimide film, using grafted MgO-templated carbon (GMgOC) as working electrode material, carbon for the counter electrode, and silver/silver chloride for the reference electrode. Pyrroloquinoline-quinone-dependent aldehyde dehydrogenase was immobilized on the working electrode, and a chamber was attached to the electrode chip and filled with 1-methoxy-5-methylphenazinium methyl sulfate solution. The sensor can be used to measure acetaldehyde gas concentrations from 0.02 to 0.1 ppm, making it suitable for monitoring human skin gas. This low detection limit was achieved by delivering the analyte through the porous polyimide film on which the electrodes were printed and accumulating acetaldehyde in the mesoporous GMgOC of the working electrode. This mechanism suggests that this sensor design can be adapted to develop other low-detection limit gas sensors, such as those for screening skin gas biomarkers.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba, 278-8510, Japan; Research Institute for Science and Technology, Tokyo University of S…
- Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba, 278-8510, Japan.
- Department of Mechanical Engineering, Faculty of Engineering, Tokyo University of Science, 3-1, Shinjuku 6-chome, Katsushika-ku, Tokyo, 125-8585, Japan.
- RIKEN Center for Biosystems Dynamics Research, 1-7-22 Suehiro-cho, Tsurumi-ku, Yokohama, Kanagawa, 230-0045, Japan.
Zitieren
APA
Shitanda, I., Oshimoto, T., Loew, N., Motosuke, M., Watanabe, H., Mikawa, T., & Itagaki, M. (2023). Biosensor development for low-level acetaldehyde gas detection using mesoporous carbon electrode printed on a porous polyimide film. Biosensors and Bioelectronics, 238, 115555. https://doi.org/10.1016/j.bios.2023.115555
Vancouver
Shitanda I, Oshimoto T, Loew N, Motosuke M, Watanabe H, Mikawa T, et al. Biosensor development for low-level acetaldehyde gas detection using mesoporous carbon electrode printed on a porous polyimide film. Biosensors and Bioelectronics. 2023;238:115555. doi:10.1016/j.bios.2023.115555
BibTeX
@article{Shitanda2023,
author = {Shitanda, Isao and Oshimoto, Taisei and Loew, Noya and Motosuke, Masahiro and Watanabe, Hikari and Mikawa, Tsutomu and Itagaki, Masayuki},
title = {Biosensor development for low-level acetaldehyde gas detection using mesoporous carbon electrode printed on a porous polyimide film},
journal = {Biosensors and Bioelectronics},
year = {2023},
volume = {238},
pages = {115555},
doi = {10.1016/j.bios.2023.115555}
}
EUVIMED