One-pot synthesis of AuPt@FexOy nanoparticles with excellent peroxidase-like activity for development of ultrasensitive colorimetric lateral flow immunoassay of cardiac troponin I
Biosensors and Bioelectronics · 2023-10 · 237 · 115508
DOI: 10.1016/j.bios.2023.115508 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2023-10. Verfasst von Haodong Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, China-Japan Union Hospital of Jilin University, Changchun, 130033, China. Hauptthemen laut MEDLINE: Metal Nanoparticles, Biosensing Techniques. Die Arbeit wurde bisher 52-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Department of Science and Technology of Jilin Province.
Abstract (Originalsprache)
Detection of cardiac troponin I (cTnI) plays a critical role in diagnosing acute myocardial infarction (AMI). In this report, a new kind of spherical AuPt@FexOy core@shell nanoparticles (termed as AuPt@FexOy NPs) were one-pot synthesized by a redox interaction-engaged strategy (RIES) without the addition of any surfactants or reducing agents. The as-synthesized AuPt@FexOy NPs not only retain the plasmonic activity of gold nanoparticles (AuNPs), but also possess excellent catalytic activities of platinum nanoparticles (PtNPs) and FexOy nanoclusters. The features of AuPt@FexOy NPs enable greatly enhance the colorimetric detection sensitivity of lateral flow immunoassay (LFIA) through integrating AuPt@FexOy NPs labeling procedure and catalyzing oxidation of chromogenic substrate 3,3',5,5'-tetramethylbenzidine (TMB) signal amplification strategy. The as-developed colorimetric LFIA (termed as AuPt@FexOy-LFIA) exhibits the limit of detection (LOD) as 26.0 pg mL-1 cTnI under the TMB signal amplification mode. In particular, the detection results of cTnI in 40 clinical seral samples by AuPt@FexOy-LFIA are correlated well with those of cTnI in the same samples by commercial enzyme-linked immunosorbent assay (ELISA) detection kit (R2 = 0.97, slope = 1), demonstrating the highly reliable analytical performance and good application prospect of AuPt@FexOy-LFIA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Cardiology, China-Japan Union Hospital of Jilin University, Changchun, 130033, China.
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, China; School of Applied Chemical Engineering, University of Science and Tec…
- Department of Cardiology, China-Japan Union Hospital of Jilin University, Changchun, 130033, China. Electronic address: heyq@jlu.edu.cn.
Förderung
- National Natural Science Foundation of China
- Department of Science and Technology of Jilin Province
Zitieren
APA
Wang, H., Yao, C., Fan, J., He, Y., & Wang, Z. (2023). One-pot synthesis of AuPt@FexOy nanoparticles with excellent peroxidase-like activity for development of ultrasensitive colorimetric lateral flow immunoassay of cardiac troponin I. Biosensors and Bioelectronics, 237, 115508. https://doi.org/10.1016/j.bios.2023.115508
Vancouver
Wang H, Yao C, Fan J, He Y, Wang Z. One-pot synthesis of AuPt@FexOy nanoparticles with excellent peroxidase-like activity for development of ultrasensitive colorimetric lateral flow immunoassay of cardiac troponin I. Biosensors and Bioelectronics. 2023;237:115508. doi:10.1016/j.bios.2023.115508
BibTeX
@article{Wang2023,
author = {Wang, Haodong and Yao, Chaoqun and Fan, Jiwen and He, Yuquan and Wang, Zhenxin},
title = {One-pot synthesis of AuPt@FexOy nanoparticles with excellent peroxidase-like activity for development of ultrasensitive colorimetric lateral flow immunoassay of cardiac troponin I},
journal = {Biosensors and Bioelectronics},
year = {2023},
volume = {237},
pages = {115508},
doi = {10.1016/j.bios.2023.115508}
}
EUVIMED