EUVIMEDEUVIMED entdecken
Crossref

Microneedle coupled epidermal sensor for multiplexed electrochemical detection of kidney disease biomarkers

Lewen Zheng, Dandan Zhu, Yi Xiao, Xinting Zheng, Peng Chen

Biosensors and Bioelectronics · 2023-10 · 237 · 115506

DOI: 10.1016/j.bios.2023.115506 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2023-10. Verfasst von Lewen Zheng und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry, Chemical Engineering and Biotechnology, Nanyang Technological University, 637457, Singapore. Hauptthemen laut MEDLINE: Biosensing Techniques, Electrochemical Techniques, Renal Insufficiency, Chronic. Die Arbeit wurde bisher 74-mal zitiert (Crossref) und nennt 52 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Early diagnosis of chronic kidney disease (CKD) and constant monitoring to guide optimal intervention is critical to prevent renal failure and other critical diseases. However, the conventional blood tests in hospital are time-consuming and have poor patient compliance. Herein, we demonstrate a real-time, minimally invasive, and self-administrable approach to detect kidney biomarkers in the skin interstitial fluid (ISF) using a polymeric microneedle coupled electrochemical sensor array (MNESA). Microneedles can readily penetrate stratum corneum and quickly extract ISF onto the sensors. Four biomarkers are simultaneously detected to avoid false positive and provide an accurate assessment of kidney functions. Using an artificial skin model, it is shown that MNSEA gives specific and sensitive responses to these kidney biomarkers in physiologically relevant ranges (phosphate: 0.3-1.8 mM, 3.62 μA/mM; uric acid: 50-550 μM, 4.19 nA/μM; creatinine: 50-550 μM, 12.58 nA/μM; urea: 1-16 mM, 44.6 mV/decade). Using a mouse model, we demonstrate that this approach is as reliable as the commercial assays and is feasible to readily monitor the progression of CDK.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesElectrochemical TechniquesRenal Insufficiency, ChronicAnimalsMiceBiomarkersNeedlesHumansEquipment DesignCreatinineExtracellular FluidUric AcidUreaEpidermis

Stichwörter der Autor:innen

Chronic kidney diseaseMicroneedle patchMultiplex electrochemical assaysSkin interstitial fluidTransdermal detection

Substanzen

BiomarkersCreatinineUric AcidUrea

Autor:innen und Institutionen

  • School of Chemistry, Chemical Engineering and Biotechnology, Nanyang Technological University, 637457, Singapore.
  • Institute of Materials Research and Engineering (IMRE), Agency for Science, Technology and Research (A*STAR), 2 Fusionopolis Way, Innovis #08-03, 138634, Singapore. Electronic address: zhengxt@imre.a-star.edu.sg.
  • School of Chemistry, Chemical Engineering and Biotechnology, Nanyang Technological University, 637457, Singapore; Skin Research Institute of Singapore, 308232, Singapore; Lee Kong Chian School of Medicine, Institute for…

Zitieren

APA

Zheng, L., Zhu, D., Xiao, Y., Zheng, X., & Chen, P. (2023). Microneedle coupled epidermal sensor for multiplexed electrochemical detection of kidney disease biomarkers. Biosensors and Bioelectronics, 237, 115506. https://doi.org/10.1016/j.bios.2023.115506

Vancouver

Zheng L, Zhu D, Xiao Y, Zheng X, Chen P. Microneedle coupled epidermal sensor for multiplexed electrochemical detection of kidney disease biomarkers. Biosensors and Bioelectronics. 2023;237:115506. doi:10.1016/j.bios.2023.115506

BibTeX
@article{Zheng2023,
  author = {Zheng, Lewen and Zhu, Dandan and Xiao, Yi and Zheng, Xinting and Chen, Peng},
  title = {Microneedle coupled epidermal sensor for multiplexed electrochemical detection of kidney disease biomarkers},
  journal = {Biosensors and Bioelectronics},
  year = {2023},
  volume = {237},
  pages = {115506},
  doi = {10.1016/j.bios.2023.115506}
}
Kostenlos starten →