EUVIMEDEUVIMED entdecken
Crossref

Highly sensitive surface plasmon resonance sensor with surface modified MoSe2/ZnO composite film for non-enzymatic glucose detection

Rong Chen, Caicheng Guo, Guilian Lan, Peng Luo, Juemin Yi, Wei Wei

Biosensors and Bioelectronics · 2023-10 · 237 · 115469

DOI: 10.1016/j.bios.2023.115469 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2023-10. Verfasst von Rong Chen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Optoelectronic Technology & Systems, Ministry of Education of China, College of Optoelectronic Engineering, Chongqing University, C…. Hauptthemen laut MEDLINE: Zinc Oxide, Biosensing Techniques, Nanostructures. Die Arbeit wurde bisher 62-mal zitiert (Crossref) und nennt 44 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The rapid and accurate assessment of glucose concentration has been demonstrated to play a significant role in human health, such as the diagnosis and treatment of diabetes, pharmaceutical research and quality monitoring in the food industry, necessitating further development of the performance for glucose sensor especially at low concentrations. However, glucose oxidase-based sensors suffer from crucial restriction in bioactivity because of their poor environmental tolerance. Recently, catalytic nanomaterials with enzyme-mimicking activity, known as nanozymes, have gained considerable interest to overcome the drawback. In this scenario, we report an inspiring surface plasmon resonance (SPR) sensor for non-enzymatic glucose detection employing ZnO nanoparticles and MoSe2 nanosheets composite (MoSe2/ZnO) as sensing film, featuring desirable advantages of high sensitivity and selectivity, lab-free and low cost. The ZnO was used to specifically recognize and bind glucose, and further signal amplification was realized by incorporating of MoSe2 owing to its larger specific surface area and favorable bio-compatibility, as well as high electron mobility. These unique features of MoSe2/ZnO composite film result in an obvious improvement of sensitivity for glucose detection. Experimental results show that the measurement sensitivity of the proposed sensor could reach 72.17 nm/(mg/mL) and a detection limit of 4.16 μg/mL by appropriately optimizing the componential constitutions of MoSe2/ZnO composite. In addition, the favorable selectivity, repeatability and stability are demonstrated as well. This facile and cost-effective work provides a novel strategy for constructing high-performance SPR sensor for glucose detection and a prospective application in biomedicine and human health monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Zinc OxideBiosensing TechniquesNanostructuresHumansSurface Plasmon ResonanceGlucose

Stichwörter der Autor:innen

Glucose sensorMoSe(2)/ZnO compositesNanozymeNon-enzymatic detectionSurface plasmon resonance

Substanzen

Zinc OxideGlucose

Autor:innen und Institutionen

  • Key Laboratory of Optoelectronic Technology & Systems, Ministry of Education of China, College of Optoelectronic Engineering, Chongqing University, Chongqing, 400044, China.
  • Suzhou Institute of Nano-tech and Nano-bionics, Chinese Academy of Sciences, Suzhou, 215123, China; Institut für Physik, Carl von Ossietzky Universität, D-26111, Oldenburg, Germany.
  • Key Laboratory of Optoelectronic Technology & Systems, Ministry of Education of China, College of Optoelectronic Engineering, Chongqing University, Chongqing, 400044, China. Electronic address: wwei@cqu.edu.cn.

Zitieren

APA

Chen, R., Guo, C., Lan, G., Luo, P., Yi, J., & Wei, W. (2023). Highly sensitive surface plasmon resonance sensor with surface modified MoSe2/ZnO composite film for non-enzymatic glucose detection. Biosensors and Bioelectronics, 237, 115469. https://doi.org/10.1016/j.bios.2023.115469

Vancouver

Chen R, Guo C, Lan G, Luo P, Yi J, Wei W. Highly sensitive surface plasmon resonance sensor with surface modified MoSe2/ZnO composite film for non-enzymatic glucose detection. Biosensors and Bioelectronics. 2023;237:115469. doi:10.1016/j.bios.2023.115469

BibTeX
@article{Chen2023,
  author = {Chen, Rong and Guo, Caicheng and Lan, Guilian and Luo, Peng and Yi, Juemin and Wei, Wei},
  title = {Highly sensitive surface plasmon resonance sensor with surface modified MoSe2/ZnO composite film for non-enzymatic glucose detection},
  journal = {Biosensors and Bioelectronics},
  year = {2023},
  volume = {237},
  pages = {115469},
  doi = {10.1016/j.bios.2023.115469}
}
Kostenlos starten →