EUVIMEDEUVIMED entdecken
Crossref

Amplification-free electrochemical biosensor detection of circulating microRNA to identify drug-induced liver injury

Appan Roychoudhury, James W Dear, Maïwenn Kersaudy-Kerhoas, Till T Bachmann

Biosensors and Bioelectronics · 2023

DOI: 10.1016/j.bios.2023.115298 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2023. Verfasst von Appan Roychoudhury und 3 weiteren Autor:innen. Beteiligte Einrichtung: Infection Medicine, Edinburgh Medical School: Biomedical Sciences, University of Edinburgh, Chancellor's Building, 49 Little France Crescent, Edinbur…. Hauptthemen laut MEDLINE: Circulating MicroRNA, Biosensing Techniques, Chemical and Drug Induced Liver Injury, MicroRNAs. Die Arbeit wurde bisher 26-mal zitiert (Crossref) und nennt 67 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Drug-induced liver injury (DILI) is a major challenge in clinical medicine and drug development. There is a need for rapid diagnostic tests, ideally at point-of-care. MicroRNA 122 (miR-122) is an early biomarker for DILI which is reported to increase in the blood before standard-of-care markers such as alanine aminotransferase activity. We developed an electrochemical biosensor for diagnosis of DILI by detecting miR-122 from clinical samples. We used electrochemical impedance spectroscopy (EIS) for direct, amplification free detection of miR-122 with screen-printed electrodes functionalised with sequence specific peptide nucleic acid (PNA) probes. We studied the probe functionalisation using atomic force microscopy and performed elemental and electrochemical characterisations. To enhance the assay performance and minimise sample volume requirements, we designed and characterised a closed-loop microfluidic system. We presented the EIS assay's specificity for wild-type miR-122 over non-complementary and single nucleotide mismatch targets. We successfully demonstrated a detection limit of 50 pM for miR-122. Assay performance could be extended to real samples; it displayed high selectivity for liver (miR-122 high) comparing to kidney (miR-122 low) derived samples extracted from murine tissue. Finally, we successfully performed an evaluation with 26 clinical samples. Using EIS, DILI patients were distinguished from healthy controls with a ROC-AUC of 0.77, a comparable performance to qPCR detection of miR-122 (ROC-AUC: 0.83). In conclusion, direct, amplification free detection of miR-122 using EIS was achievable at clinically relevant concentrations and in clinical samples. Future work will focus on realising a full sample-to-answer system which can be deployed for point-of-care testing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Circulating MicroRNABiosensing TechniquesChemical and Drug Induced Liver InjuryMicroRNAsHumansMiceAnimalsPoint-of-Care TestingPoint-of-Care SystemsElectrochemical Techniques

Stichwörter der Autor:innen

Continuous-flow measurementsDrug-induced liver injuryElectrochemical impedance spectroscopyPoint-of-care diagnosticsmicroRNA detection

Substanzen

Circulating MicroRNAMicroRNAsMIRN122 microRNA, human

Autor:innen und Institutionen

  • Infection Medicine, Edinburgh Medical School: Biomedical Sciences, University of Edinburgh, Chancellor's Building, 49 Little France Crescent, Edinburgh, EH16 4SB, UK.
  • Centre for Cardiovascular Science, University of Edinburgh, The Queen's Medical Research Institute, 47 Little France Crescent, Edinburgh, EH16 4TJ, UK.
  • Infection Medicine, Edinburgh Medical School: Biomedical Sciences, University of Edinburgh, Chancellor's Building, 49 Little France Crescent, Edinburgh, EH16 4SB, UK; Institute of Biological Chemistry, Biophysics and Bi…
  • Infection Medicine, Edinburgh Medical School: Biomedical Sciences, University of Edinburgh, Chancellor's Building, 49 Little France Crescent, Edinburgh, EH16 4SB, UK. Electronic address: till.bachmann@ed.ac.uk.

Zitieren

APA

Roychoudhury, A., Dear, J. W., Kersaudy-Kerhoas, M., & Bachmann, T. T. (2023). Amplification-free electrochemical biosensor detection of circulating microRNA to identify drug-induced liver injury. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2023.115298

Vancouver

Roychoudhury A, Dear JW, Kersaudy-Kerhoas M, Bachmann TT. Amplification-free electrochemical biosensor detection of circulating microRNA to identify drug-induced liver injury. Biosensors and Bioelectronics. 2023. doi:10.1016/j.bios.2023.115298

BibTeX
@article{Roychoudhury2023,
  author = {Roychoudhury, Appan and Dear, James W and Kersaudy-Kerhoas, Maïwenn and Bachmann, Till T},
  title = {Amplification-free electrochemical biosensor detection of circulating microRNA to identify drug-induced liver injury},
  journal = {Biosensors and Bioelectronics},
  year = {2023},
  doi = {10.1016/j.bios.2023.115298}
}
Kostenlos starten →