Ultrathin MXene nanosheet-based TiO2/CdS heterostructure as a photoelectrochemical sensor for detection of CEA in human serum samples
Biosensors and Bioelectronics · 2023-06 · 230 · 115287
DOI: 10.1016/j.bios.2023.115287 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2023-06. Verfasst von Yantian Shi und 9 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Ministry of Education, College of Chemistry and Molecular Enginee…. Hauptthemen laut MEDLINE: Electrochemical Techniques, Biosensing Techniques. Die Arbeit wurde bisher 65-mal zitiert (Crossref) und nennt 51 Literaturangaben. Gefördert von: Natural Science Foundation of Shandong Province, Shandong Key Laboratory of Biochemical Analysis, National Natural Science Foundation of China.
Abstract (Originalsprache)
To develop highly accurate and ultrasensitive strategies is of great importance for the clinical measurement, in particular, the detection of cancer biomarkers. Herein, we synthesized an ultrasensitive TiO2/MXene/CdS QDs (TiO2/MX/CdS) heterostructure as a photoelectrochemical immunosensor, which favors energy levels matching and fast electron transfer from CdS to TiO2 in the help of ultrathin MXene nanosheet. Dramatic photocurrent quenching can be observed upon incubation of the TiO2/MX/CdS electrode by Cu2+ solution from 96-well microplate, which caused by the formation of CuS and subsequent CuxS (x = 1, 2), reducing the absorption of light and boosting the electron-hole recombination upon irradiation. As a result, the as-prepared biosensor demonstrates a linearly increased photocurrent quenching percentage (Q%) value with CEA concentration ranging from 1 fg/mL to 10 ng/mL, as well as a low detection limit of 0.24 fg/mL. Benefit from its excellent stability, high selectivity and good reproducibility of as-prepared PEC immunosensor, we believe that this proposed strategy might provide new opportunities for clinical diagnosis of CEA and other tumor markers.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, C…
- College of Chemical and Biological Engineering, Shandong University of Science and Technology, Qingdao, Shandong, 266590, PR China. Electronic address: jliu99@126.com.
Förderung
- Natural Science Foundation of Shandong Province
- Shandong Key Laboratory of Biochemical Analysis
- National Natural Science Foundation of China
Zitieren
APA
Shi, Y., Li, T., Zhao, L., Liu, Y., Ding, K., Li, D., He, P., Jiang, D., Liu, J., & Zhou, H. (2023). Ultrathin MXene nanosheet-based TiO2/CdS heterostructure as a photoelectrochemical sensor for detection of CEA in human serum samples. Biosensors and Bioelectronics, 230, 115287. https://doi.org/10.1016/j.bios.2023.115287
Vancouver
Shi Y, Li T, Zhao L, Liu Y, Ding K, Li D, et al. Ultrathin MXene nanosheet-based TiO2/CdS heterostructure as a photoelectrochemical sensor for detection of CEA in human serum samples. Biosensors and Bioelectronics. 2023;230:115287. doi:10.1016/j.bios.2023.115287
BibTeX
@article{Shi2023,
author = {Shi, Yantian and Li, Tiantian and Zhao, Lin and Liu, Yaojia and Ding, Kexin and Li, Dongxiang and He, Peng and Jiang, Degang and Liu, Jing and Zhou, Hong},
title = {Ultrathin MXene nanosheet-based TiO2/CdS heterostructure as a photoelectrochemical sensor for detection of CEA in human serum samples},