EUVIMEDEUVIMED entdecken
Crossref

A self-designed device integrated with a Fermat spiral microfluidic chip for ratiometric and automated point-of-care testing of anthrax biomarker in real samples

Xiaodong Lin, Haotian Wu, Shiyu Zeng, Tao Peng, Pan Zhang, Xinhua Wan, Yihan Lang, Biao Zhang, Yanwei Jia, Ren Shen, Binfeng Yin

Biosensors and Bioelectronics · 2023-06 · 230 · 115283

DOI: 10.1016/j.bios.2023.115283 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2023-06. Verfasst von Xiaodong Lin und 10 weiteren Autor:innen. Beteiligte Einrichtung: Zhuhai UM Science & Technology Research Institute, Zhuhai, 519000, China. Electronic address: lxdlxf2011@163.com. Hauptthemen laut MEDLINE: Anthrax, Biosensing Techniques. Die Arbeit wurde bisher 44-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: Jiangsu Provincial Agricultural Science and Technology Innovation Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A desirable lanthanide-based ratiometric fluorescent probe was designed and integrated into a self-designed Fermat spiral microfluidic chip (FS-MC) for the automated determination of a unique bacterial endospore biomarker, dipicolinic acid (DPA), with high selectivity and sensitivity. Here, a blue emission wavelength at 425 nm was generated in the Fermat spiral structure by mixing the europium (Eu3+) and luminol to form the Eu3+/Luminol sensing probe. DPA in the reservoir can be used to specifically bind to Eu3+ under the negative pressure and transfer energy from DPA to Eu3+ sequentially via an antenna effect, thus resulting in a significant increase in the red fluorescence emission peak at 615 nm. According to the fluorescence intensity ratio (F615/F425), a good linearity can be obtained with increasing the concentration of DPA from 0 to 200 μM with a limit of detection as low as 10.11 nM. Interestingly, the designed FS-MC can achieve rapid detection of DPA in only 1 min, reducing detection time and improving sensitivity. Furthermore, a self-designed device integrated with the FS-MC and a smartphone color picker APP was employed for the rapid automatic point-of-care testing (POCT) of DPA in the field, simplifying complex processes and reducing testing times, thus confirming the great promise of this ready-to-use measurement platform for in situ inspection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AnthraxBiosensing TechniquesHumansMicrofluidicsLuminolFluorescent DyesPoint-of-Care TestingBiomarkers

Stichwörter der Autor:innen

DPA detectionFermat spiral microfluidic chip (FS-MC)Point-of-care testing (POCT)Ratiometric fluorescenceSelf-designed device

Substanzen

LuminolFluorescent DyesBiomarkers

Autor:innen und Institutionen

  • Zhuhai UM Science & Technology Research Institute, Zhuhai, 519000, China. Electronic address: lxdlxf2011@163.com.
  • State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin, 300457, China.
  • School of Mechanical Engineering, Yangzhou University, Yangzhou, 225127, China.
  • Zhuhai UM Science & Technology Research Institute, Zhuhai, 519000, China.
  • State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Macau, China; National Key Lab of MicroNanofabrication Technology, School of Integrated Circuits, Peking Universi…
  • Zhejiang Provincial Key Laboratory of Biometrology and Inspection & Quarantine, College of Life Sciences, China Jiliang University, Hangzhou, 310018, China.

Förderung

  • Jiangsu Provincial Agricultural Science and Technology Innovation Fund

Zitieren

APA

Lin, X., Wu, H., Zeng, S., Peng, T., Zhang, P., Wan, X., Lang, Y., Zhang, B., Jia, Y., Shen, R., & Yin, B. (2023). A self-designed device integrated with a Fermat spiral microfluidic chip for ratiometric and automated point-of-care testing of anthrax biomarker in real samples. Biosensors and Bioelectronics, 230, 115283. https://doi.org/10.1016/j.bios.2023.115283

Vancouver

Lin X, Wu H, Zeng S, Peng T, Zhang P, Wan X, et al. A self-designed device integrated with a Fermat spiral microfluidic chip for ratiometric and automated point-of-care testing of anthrax biomarker in real samples. Biosensors and Bioelectronics. 2023;230:115283. doi:10.1016/j.bios.2023.115283

BibTeX
@article{Lin2023,
  author = {Lin, Xiaodong and Wu, Haotian and Zeng, Shiyu and Peng, Tao and Zhang, Pan and Wan, Xinhua and Lang, Yihan and Zhang, Biao and Jia, Yanwei and Shen, Ren and Yin, Binfeng},
  title = {A self-designed device integrated with a Fermat spiral microfluidic chip for ratiometric and automated point-of-care testing of anthrax biomarker in real samples},
  journal = {Biosensors and Bioelectronics},
  year = {2023},
  volume = {230},
  pages = {115283},
  doi = {10.1016/j.bios.2023.115283}
}
Kostenlos starten →