EUVIMEDEUVIMED entdecken
Crossref

An ion-coordination hydrogel based sensor array for point-of-care identification and removal of multiple tetracyclines

Yujie Zhang, Tianlin Wang, Hanqiong Guo, Xia Gao, Yong Yan, Xiao Zhou, Minyang Zhao, Haijuan Qin, Yaqing Liu

Biosensors and Bioelectronics · 2023-07 · 231 · 115266

DOI: 10.1016/j.bios.2023.115266 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2023-07. Verfasst von Yujie Zhang und 8 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Food Nutrition and Safety, College of Food Science and Engineering, Tianjin University of Science and Technology, Tianjin, 30…. Hauptthemen laut MEDLINE: Tetracyclines, Biosensing Techniques. Die Arbeit wurde bisher 56-mal zitiert (Crossref) und nennt 45 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Misuse and overuse of tetracycline antibiotics (TCs) brings serious issues to ecological environment, food safety and human health. It is urgent to develop unique platform for high efficient identification and removal of TCs. In the present investigation, an effective and simple fluorescence sensor array was constructed based on the interaction between metal ions (Eu3+ and Al3+) and antibiotics. Benefiting from the different affinities between the ions and TCs, the sensor array can identify TCs from other antibiotics, which also can further differentiating four kinds of TCs (OTC, CTC, TC and DOX) from each other via linear discriminant analysis (LDA) technique. Meanwhile, the sensor array performed well in quantitative analysis of single TC antibiotic and differentiation of TCs mixtures. More interestingly, Eu3+ and Al3+-doped sodium alginate/polyvinyl alcohol hydrogel beads (SA/Eu/PVA and SA/Al/PVA) were further constructed, which can not only identify the TCs but simultaneously remove the antibiotics with high efficiency. The investigation provided an instructive way for rapid detection and environment protection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TetracyclinesBiosensing TechniquesHumansHydrogelsPoint-of-Care SystemsAnti-Bacterial AgentsIons

Stichwörter der Autor:innen

Multiple identificationRemoval of antibioticsSensor arrayTetracyclines

Substanzen

TetracyclinesHydrogelsAnti-Bacterial AgentsIons

Autor:innen und Institutionen

  • State Key Laboratory of Food Nutrition and Safety, College of Food Science and Engineering, Tianjin University of Science and Technology, Tianjin, 300457, China.
  • College of Food Science and Technology, Henan Agricultural University, Zhengzhou, 450002, Henan, China.
  • State Key Laboratory of Food Nutrition and Safety, College of Food Science and Engineering, Tianjin University of Science and Technology, Tianjin, 300457, China. Electronic address: yaqingliu@tust.edu.cn.

Zitieren

APA

Zhang, Y., Wang, T., Guo, H., Gao, X., Yan, Y., Zhou, X., Zhao, M., Qin, H., & Liu, Y. (2023). An ion-coordination hydrogel based sensor array for point-of-care identification and removal of multiple tetracyclines. Biosensors and Bioelectronics, 231, 115266. https://doi.org/10.1016/j.bios.2023.115266

Vancouver

Zhang Y, Wang T, Guo H, Gao X, Yan Y, Zhou X, et al. An ion-coordination hydrogel based sensor array for point-of-care identification and removal of multiple tetracyclines. Biosensors and Bioelectronics. 2023;231:115266. doi:10.1016/j.bios.2023.115266

BibTeX
@article{Zhang2023,
  author = {Zhang, Yujie and Wang, Tianlin and Guo, Hanqiong and Gao, Xia and Yan, Yong and Zhou, Xiao and Zhao, Minyang and Qin, Haijuan and Liu, Yaqing},
  title = {An ion-coordination hydrogel based sensor array for point-of-care identification and removal of multiple tetracyclines},
  journal = {Biosensors and Bioelectronics},
  year = {2023},
  volume = {231},
  pages = {115266},
  doi = {10.1016/j.bios.2023.115266}
}
Kostenlos starten →