EUVIMEDEUVIMED entdecken
Open Access

Stable in-vivo electrochemical sensing of tonic serotonin levels using PEDOT/CNT-coated glassy carbon flexible microelectrode arrays.

Elisa Castagnola, Elaine M Robbins, Daniela D Krahe, Bingchen Wu, May Yoon Pwint, Qun Cao, Xinyan Tracy Cui

Biosensors and Bioelectronics · 2023-06 · 230 · 115242

DOI: 10.1016/j.bios.2023.115242 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2023-06. Verfasst von Elisa Castagnola und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioengineering, University of Pittsburgh, 3501 Fifth Ave. Pittsburgh, PA 15260, Pittsburgh, PA, USA; Department of Biomedical Engineeri…. Hauptthemen laut MEDLINE: Serotonin, Biosensing Techniques. Die Arbeit wurde bisher 56-mal zitiert (Crossref) und nennt 105 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NINDS NIH HHS, NIMH NIH HHS, NIDA NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Chronic sampling of tonic serotonin (5-hydroxytryptamine, 5-HT) concentrations in the brain is critical for tracking neurological disease development and the time course of pharmacological treatments. Despite their value, in vivo chronic multi-site measurements of tonic 5-HT have not been reported. To fill this technological gap, we batch-fabricated implantable glassy carbon (GC) microelectrode arrays (MEAs) onto a flexible SU-8 substrate to provide an electrochemically stable and biocompatible device/tissue interface. To achieve detection of tonic 5-HT concentrations, we applied a poly(3,4-ethylenedioxythiophene)/carbon nanotube (PEDOT/CNT) electrode coating and optimized a square wave voltammetry (SWV) waveform for selective 5-HT measurement. In vitro, the PEDOT/CNT-coated GC microelectrodes achieved high sensitivity to 5-HT, good fouling resistance, and excellent selectivity against the most common neurochemical interferents. In vivo, our PEDOT/CNT-coated GC MEAs successfully detected basal 5-HT concentrations at different locations within the CA2 region of the hippocampus of both anesthetized and awake mice. Furthermore, the PEDOT/CNT-coated MEAs were able to detect tonic 5-HT in the mouse hippocampus for one week after implantation. Histology reveals that the flexible GC MEA implants caused less tissue damage and reduced inflammatory response in the hippocampus compared to commercially available stiff silicon probes. To the best of our knowledge, this PEDOT/CNT-coated GC MEA is the first implantable, flexible sensor capable of chronic in vivo multi-site sensing of tonic 5-HT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SerotoninBiosensing TechniquesMiceAnimalsMicroelectrodesPolymersBridged Bicyclo Compounds, Heterocyclic

Stichwörter der Autor:innen

Electrochemical sensingGlassy carbonMicroelectrode arrays (MEAs)PEDOT/CNTSerotoninSquare wave voltammetry

Substanzen

poly(3,4-ethylene dioxythiophene)SerotoninPolymersBridged Bicyclo Compounds, Heterocyclic

Autor:innen und Institutionen

  • Department of Bioengineering, University of Pittsburgh, 3501 Fifth Ave. Pittsburgh, PA 15260, Pittsburgh, PA, USA; Department of Biomedical Engineering, Louisiana Tech University, Ruston, LA, 818 Nelson Ave, 71272, USA.
  • Department of Bioengineering, University of Pittsburgh, 3501 Fifth Ave. Pittsburgh, PA 15260, Pittsburgh, PA, USA.
  • Department of Bioengineering, University of Pittsburgh, 3501 Fifth Ave. Pittsburgh, PA 15260, Pittsburgh, PA, USA; Center for Neural Basis of Cognition, University of Pittsburgh, 4400 Fifth Ave, PA 15213, Pittsburgh, PA…
  • Department of Bioengineering, University of Pittsburgh, 3501 Fifth Ave. Pittsburgh, PA 15260, Pittsburgh, PA, USA; McGowan Institute for Regenerative Medicine, University of Pittsburgh, 450 Technology Drive, Pittsburgh,…

Förderung

  • NINDS NIH HHS
  • NIMH NIH HHS
  • NIDA NIH HHS
  • National Institutes of Health
  • National Institute of Neurological Disorders and Stroke

Zitieren

APA

Castagnola, E., Robbins, E. M., Krahe, D. D., Wu, B., Pwint, M. Y., Cao, Q., & Cui, X. T. (2023). Stable in-vivo electrochemical sensing of tonic serotonin levels using PEDOT/CNT-coated glassy carbon flexible microelectrode arrays. Biosensors and Bioelectronics, 230, 115242. https://doi.org/10.1016/j.bios.2023.115242

Vancouver

Castagnola E, Robbins EM, Krahe DD, Wu B, Pwint MY, Cao Q, et al. Stable in-vivo electrochemical sensing of tonic serotonin levels using PEDOT/CNT-coated glassy carbon flexible microelectrode arrays. Biosensors and Bioelectronics. 2023;230:115242. doi:10.1016/j.bios.2023.115242

BibTeX
@article{Castagnola2023,
  author = {Castagnola, Elisa and Robbins, Elaine M and Krahe, Daniela D and Wu, Bingchen and Pwint, May Yoon and Cao, Qun and Cui, Xinyan Tracy},
  title = {Stable in-vivo electrochemical sensing of tonic serotonin levels using PEDOT/CNT-coated glassy carbon flexible microelectrode arrays},
  journal = {Biosensors and Bioelectronics},
  year = {2023},
  volume = {230},
  pages = {115242},
  doi = {10.1016/j.bios.2023.115242}
}
Kostenlos starten →