EUVIMEDEUVIMED entdecken
Crossref

A novel bimetallic MXene derivative QD-based ECL sensor for miRNA-27a-3p detection

Mingxuan Li, Zhenrun Li, Peilin Wang, Qiang Ma

Biosensors and Bioelectronics · 2023-05 · 228 · 115225

DOI: 10.1016/j.bios.2023.115225 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2023-05. Verfasst von Mingxuan Li und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun, 130012, China. Hauptthemen laut MEDLINE: Biosensing Techniques, Quantum Dots, MicroRNAs. Die Arbeit wurde bisher 52-mal zitiert (Crossref) und nennt 49 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this work, a novel ECL biosensor has been developed based on bimetallic MXene derivative QDs (Mo2TiC2 QDs) and SnS2 nanosheets/lipid bilayer to detect the gastric cancer marker miRNA-27a-3p. On the one hand, the inter-band excitation of Mo2TiC2 QDs can inject the additional carriers, which were less suppressed by boundary effects and made a significant contribution to the luminescence process. Semiconductor Mo2TiC2 further inhibited the formation of internal electric field and potential oxidation. Therefore, Mo2TiC2 QDs processed superior luminous intensity and better stability. On the other hand, SnS2 nanosheets coated with phospholipid bilayer were designed as sensing interface. SnS2 nanosheets not only enhanced the luminous intensity of Mo2TiC2 QDs by virtue of their large surface area and low dielectric constant, but also improved the stability of lipid bilayer. Due to the excellent properties and synergy work of Mo2TiC2 QDs and the lipid bilayer-modified SnS2 nanosheets, the sensing system displayed high sensitivity and good reproducibility in the analysis application. As a result, the biosensor displayed good linear correlation between the ECL intensity and the concentration of miRNA-27a-3p over a wide range from 1 fM to 10 nM with the detection limit as low as 1 fM. The sensing system including the joint contribution of Mo2TiC2 QDs, SnS2 nanosheets and lipid bilayers had great potential for clinical applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesQuantum DotsMicroRNAsLuminescent MeasurementsReproducibility of ResultsLipid BilayersElectrochemical TechniquesNitritesTransition Elements

Stichwörter der Autor:innen

Lipid bilayerMXene derivative nanomaterialsMiRNA detectionMo(2)TiC(2) QDsSnS(2) nanosheet

Substanzen

Lipid BilayersMicroRNAsMXeneNitritesTransition Elements

Autor:innen und Institutionen

  • Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun, 130012, China.
  • Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun, 130012, China. Electronic address: qma@jlu.edu.cn.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Li, M., Li, Z., Wang, P., & Ma, Q. (2023). A novel bimetallic MXene derivative QD-based ECL sensor for miRNA-27a-3p detection. Biosensors and Bioelectronics, 228, 115225. https://doi.org/10.1016/j.bios.2023.115225

Vancouver

Li M, Li Z, Wang P, Ma Q. A novel bimetallic MXene derivative QD-based ECL sensor for miRNA-27a-3p detection. Biosensors and Bioelectronics. 2023;228:115225. doi:10.1016/j.bios.2023.115225

BibTeX
@article{Li2023,
  author = {Li, Mingxuan and Li, Zhenrun and Wang, Peilin and Ma, Qiang},
  title = {A novel bimetallic MXene derivative QD-based ECL sensor for miRNA-27a-3p detection},
  journal = {Biosensors and Bioelectronics},
  year = {2023},
  volume = {228},
  pages = {115225},
  doi = {10.1016/j.bios.2023.115225}
}
Kostenlos starten →