EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Smartphone-based 3D-printed electrochemiluminescence enzyme biosensor for reagentless glucose quantification in real matrices

Donato Calabria, Elisa Lazzarini, Andrea Pace, Ilaria Trozzi, Martina Zangheri, Stefano Cinti, Marinella Difonzo, Giovanni Valenti, Massimo Guardigli, Francesco Paolucci, Mara Mirasoli

Biosensors and Bioelectronics · 2023-05 · 227 · 115146

DOI: 10.1016/j.bios.2023.115146 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2023-05. Verfasst von Donato Calabria und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry "Giacomo Ciamician", Alma Mater Studiorum - University of Bologna, Via Selmi 2, I-40126, Bologna, Italy; Interdepartmental Ce…. Hauptthemen laut MEDLINE: Glucose, Biosensing Techniques. Die Arbeit wurde bisher 69-mal zitiert (Crossref) und nennt 69 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministero dell’Istruzione, dell’Università e della Ricerca.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Three-dimensional (3D) printed electrochemical devices are increasingly used in point-of-need and point-of-care testing. They show several advantages such as simple fabrication, low cost, fast response, and excellent selectivity and sensitivity in small sample volumes. However, there are only a few examples of analytical devices combining 3D-printed electrodes with electrochemiluminescence (ECL) detection, an electrochemical detection principle widely employed in clinical chemistry analysis. Herein, a portable, 3D-printed miniaturized ECL biosensor for glucose detection has been developed, based on the luminol/H2O2 ECL system and employing a two-electrode configuration with carbon black-doped polylactic acid (PLA) electrodes. The ECL emission is obtained by means of a 1.5V AA alkaline battery and detected using a smartphone camera, thus providing easy portability of the analytical platform. The ECL system was successfully applied for sensing H2O2 and, upon coupling the luminol/H2O2 system with the enzyme glucose oxidase, for glucose detection. The incorporation of luminol and glucose oxidase in an agarose hydrogel matrix allowed to produce ECL devices preloaded with the reagents required for the assay, so that the analysis only required sample addition. The ECL biosensor showed an excellent ability to detect glucose up to 5 mmol L-1, with a limit of detection of 60 μmol L-1. The biosensor was also used to analyse real samples (i.e., glucose saline solutions and artificial serum samples) with satisfactory results, thus suggesting its suitability for point-of-care analysis. Coupling with other oxidases could further extend the applicability of this analytical platform.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GlucoseBiosensing TechniquesLuminolGlucose OxidaseSmartphoneHydrogen PeroxideLuminescent MeasurementsElectrodesPrinting, Three-DimensionalElectrochemical Techniques

Stichwörter der Autor:innen

3D printingBiosensorConductive PLAElectrochemiluminescenceGlucoseLuminol

Substanzen

GlucoseLuminolGlucose OxidaseHydrogen Peroxide

Autor:innen und Institutionen

  • Department of Chemistry "Giacomo Ciamician", Alma Mater Studiorum - University of Bologna, Via Selmi 2, I-40126, Bologna, Italy; Interdepartmental Centre for Industrial Aerospace Research (CIRI AEROSPACE), Alma Mater St…
  • Department of Chemistry "Giacomo Ciamician", Alma Mater Studiorum - University of Bologna, Via Selmi 2, I-40126, Bologna, Italy.
  • Department of Chemistry "Giacomo Ciamician", Alma Mater Studiorum - University of Bologna, Via Selmi 2, I-40126, Bologna, Italy; Interdepartmental Centre for Industrial Agrofood Research (CIRI AGRO), Alma Mater Studioru…
  • Department of Pharmacy, University Naples Federico II, Via Domenico Montesano 49, I-80131, Naples, Italy; BAT Center-Interuniversity Center for Studies on Bioinspired Agro-Environmental Technology, University of Napoli…
  • Department of Chemistry "Giacomo Ciamician", Alma Mater Studiorum - University of Bologna, Via Selmi 2, I-40126, Bologna, Italy. Electronic address: francesco.paolucci@unibo.it.

Förderung

  • Ministero dell’Istruzione, dell’Università e della Ricerca

Zitieren

APA

Calabria, D., Lazzarini, E., Pace, A., Trozzi, I., Zangheri, M., Cinti, S., Difonzo, M., Valenti, G., Guardigli, M., Paolucci, F., & Mirasoli, M. (2023). Smartphone-based 3D-printed electrochemiluminescence enzyme biosensor for reagentless glucose quantification in real matrices. Biosensors and Bioelectronics, 227, 115146. https://doi.org/10.1016/j.bios.2023.115146

Vancouver

Calabria D, Lazzarini E, Pace A, Trozzi I, Zangheri M, Cinti S, et al. Smartphone-based 3D-printed electrochemiluminescence enzyme biosensor for reagentless glucose quantification in real matrices. Biosensors and Bioelectronics. 2023;227:115146. doi:10.1016/j.bios.2023.115146

BibTeX
@article{Calabria2023,
  author = {Calabria, Donato and Lazzarini, Elisa and Pace, Andrea and Trozzi, Ilaria and Zangheri, Martina and Cinti, Stefano and Difonzo, Marinella and Valenti, Giovanni and Guardigli, Massimo and Paolucci, Francesco and Mirasoli, Mara},
  title = {Smartphone-based 3D-printed electrochemiluminescence enzyme biosensor for reagentless glucose quantification in real matrices},
  journal = {Biosensors and Bioelectronics},
  year = {2023},
  volume = {227},
  pages = {115146},
  doi = {10.1016/j.bios.2023.115146}
}
Kostenlos starten →