Joint-detection of Salmonella typhimurium and Escherichia coli O157:H7 by an immersible amplification dip-stick immunoassay
Biosensors and Bioelectronics · 2023-03 · 224 · 115075
DOI: 10.1016/j.bios.2023.115075 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2023-03. Verfasst von Yaqian Chen und 9 weiteren Autor:innen. Beteiligte Einrichtung: College of Food Science and Engineering, Northwest A&F University, 22 Xinong Road, Yangling, 712100, Shaanxi, China. Hauptthemen laut MEDLINE: Escherichia coli O157, Biosensing Techniques. Die Arbeit wurde bisher 39-mal zitiert (Crossref) und nennt 26 Literaturangaben.
Abstract (Originalsprache)
To explore the superiority of multifunctional nanocomposites and realize the joint-detection of foodborne pathogens, an immersible amplification dip-stick immunoassay (DSIA) was exploited for the sensitive detection of Salmonella typhimurium (S. typhi) and Escherichia coli O157:H7 (E. coli O157:H7). Saving for the basic colorimetric performance, the reporter molecule of CoFe2O4 (CFO) possesses multivalent elements (Co2+/3+, Fe2+/3+) as well as multifunction of superior catalase-like activity and magnetic properties. By dint of the catalytic activity of CFO, a directly immersible amplification can be simply achieved to endure the DSIA with an intensive signal and a dual-visible mode for the determination of S. typhi and E. coli O157:H7. In virtue of the magnetic separation and enrichment capability of the CFO, the DSIA can perform a matrix-interference-free detection and obtain a dynamic detection range of 102-108 CFU/mL and a low assay limit of 102 CFU/mL. Moreover, the DSIA has reasonable recovery rates for contamination monitoring of two target bacteria in milk and beef samples. Our research provides a persuasive supplement for the application of multifunctional nanocomposites in the ongoing dip-stick immunoassay and an alternative strategy for the efficient detection of foodborne pathogens.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Food Science and Engineering, Northwest A&F University, 22 Xinong Road, Yangling, 712100, Shaanxi, China.
- Bio-Nanotechnology Research Institute, Ludong University, Yantai, 264025, Shandong, China. Electronic address: vetzhao@163.com.
- Qinghai Provincial Key Laboratory of Qinghai-Tibet Plateau Biological Resources, Northwest Institute of Plateau Biology, Chinese Academy of Sciences, Xining, 810008, Qinghai, China.
- College of Food Science and Engineering, Northwest A&F University, 22 Xinong Road, Yangling, 712100, Shaanxi, China. Electronic address: zhangdh@nwsuaf.edu.cn.
Zitieren
APA
Chen, Y., Ma, J., Yin, X., Deng, Z., Liu, X., Yang, D., Zhao, L., Sun, J., Wang, J., & Zhang, D. (2023). Joint-detection of Salmonella typhimurium and Escherichia coli O157:H7 by an immersible amplification dip-stick immunoassay. Biosensors and Bioelectronics, 224, 115075. https://doi.org/10.1016/j.bios.2023.115075
Vancouver
Chen Y, Ma J, Yin X, Deng Z, Liu X, Yang D, et al. Joint-detection of Salmonella typhimurium and Escherichia coli O157:H7 by an immersible amplification dip-stick immunoassay. Biosensors and Bioelectronics. 2023;224:115075. doi:10.1016/j.bios.2023.115075
BibTeX
@article{Chen2023,
author = {Chen, Yaqian and Ma, Jiaqi and Yin, Xuechi and Deng, Ziai and Liu, Xiaojing and Yang, Di and Zhao, Lei and Sun, Jing and Wang, Jianlong and Zhang, Daohong},
title = {Joint-detection of Salmonella typhimurium and Escherichia coli O157:H7 by an immersible amplification dip-stick immunoassay},
journal = {Biosensors and Bioelectronics},
year = {2023},
volume = {224},
pages = {115075},
doi = {10.1016/j.bios.2023.115075}
}
EUVIMED