EUVIMEDEUVIMED entdecken
Crossref

Wearable potentiometric biosensor for analysis of urea in sweat

Gisela Ibáñez-Redín, Giovana Rosso Cagnani, Nathalia O Gomes, Paulo A Raymundo-Pereira, Sergio A S Machado, Marco Antonio Gutierrez, Jose Eduardo Krieger, Osvaldo N Oliveira

Biosensors and Bioelectronics · 2023-03 · 223 · 114994

DOI: 10.1016/j.bios.2022.114994 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2023-03. Verfasst von Gisela Ibáñez-Redín und 7 weiteren Autor:innen. Beteiligte Einrichtung: Sao Carlos Institute of Physics, University of São Paulo (USP), São Carlos, São Paulo, 13560-970, Brazil. Electronic address: gibanezredin@alumni.usp…. Hauptthemen laut MEDLINE: Biosensing Techniques, Wearable Electronic Devices. Die Arbeit wurde bisher 121-mal zitiert (Crossref) und nennt 56 Literaturangaben. Gefördert von: Fundação de Amparo à Pesquisa do Estado de São Paulo, Conselho Nacional de Desenvolvimento Científico e Tecnológico, Instituto Nacional de Ciência e Tecnologia em Eletrônica Orgânica.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Herein, we introduce wearable potentiometric biosensors on screen-printed carbon electrodes (SPCEs) for on-body and on-site monitoring of urea in sweat. The biosensor architecture was judiciously designed to detect urea at different pHs and incorporate a pH sensor, thus containing polyaniline ink, urease bioink and a polyvinylchloride membrane. Urea detection could be performed in the wide range from 5 to 200 mM at pH 7.0, encompassing urea levels in human sweat. The biosensor response was fast (incubation time 5 min), with no interference from other substances in sweat. Reliable urea detection could be done in undiluted human sweat with a skin-worn flexible device using the pH correction strategy afforded by the pH sensor. The performance of the epidermal biosensor was not affected by severe bending strains. The feasibility of mass production was demonstrated by fabricating epidermal flexible biosensors using slot-die coating with a roll-to-roll technique.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesWearable Electronic DevicesHumansSweatUreaPotentiometry

Stichwörter der Autor:innen

Electrochemical biosensorsRoll-to-roll processingSweatUreaWearable sensors

Substanzen

Urea

Autor:innen und Institutionen

  • Sao Carlos Institute of Physics, University of São Paulo (USP), São Carlos, São Paulo, 13560-970, Brazil. Electronic address: gibanezredin@alumni.usp.br.
  • São Carlos Institute of Chemistry, University of São Paulo (USP), São Carlos, São Paulo, 13560-970, Brazil.
  • Sao Carlos Institute of Physics, University of São Paulo (USP), São Carlos, São Paulo, 13560-970, Brazil.
  • Heart Institute (InCor), University of São Paulo (USP) Medical School, São Paulo, 05403-900, Brazil.
  • Sao Carlos Institute of Physics, University of São Paulo (USP), São Carlos, São Paulo, 13560-970, Brazil. Electronic address: chu@ifsc.usp.br.

Förderung

  • Fundação de Amparo à Pesquisa do Estado de São Paulo
  • Conselho Nacional de Desenvolvimento Científico e Tecnológico
  • Instituto Nacional de Ciência e Tecnologia em Eletrônica Orgânica

Zitieren

APA

Ibáñez-Redín, G., Rosso Cagnani, G., O Gomes, N., Raymundo-Pereira, P. A., S Machado, S. A., Gutierrez, M. A., Krieger, J. E., & Oliveira, O. N. (2023). Wearable potentiometric biosensor for analysis of urea in sweat. Biosensors and Bioelectronics, 223, 114994. https://doi.org/10.1016/j.bios.2022.114994

Vancouver

Ibáñez-Redín G, Rosso Cagnani G, O Gomes N, Raymundo-Pereira PA, S Machado SA, Gutierrez MA, et al. Wearable potentiometric biosensor for analysis of urea in sweat. Biosensors and Bioelectronics. 2023;223:114994. doi:10.1016/j.bios.2022.114994

BibTeX
@article{IbezRedn2023,
  author = {Ibáñez-Redín, Gisela and Rosso Cagnani, Giovana and O Gomes, Nathalia and Raymundo-Pereira, Paulo A and S Machado, Sergio A and Gutierrez, Marco Antonio and Krieger, Jose Eduardo and Oliveira, Osvaldo N},
  title = {Wearable potentiometric biosensor for analysis of urea in sweat},
  journal = {Biosensors and Bioelectronics},
  year = {2023},
  volume = {223},
  pages = {114994},
  doi = {10.1016/j.bios.2022.114994}
}
Kostenlos starten →