EUVIMEDEUVIMED entdecken
Crossref

Highly sensitive standardized toxicity biosensors for rapid water quality warning

Huijuan Su, Jiaguo Yan, Xuejun Yan, Qian Zhao, Chengmei Liao, Nan Li, Xin Wang

Bioresource Technology · 2024

DOI: 10.1016/j.biortech.2024.130985 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioresource Technology, 2024. Verfasst von Huijuan Su und 6 weiteren Autor:innen. Beteiligte Einrichtung: MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, Coll…. Hauptthemen laut MEDLINE: Biosensing Techniques. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Fundamental Research Funds for the Central Universities, NSFC, Ministry of Education of the People's Republic of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microbial electrochemical sensor (MES) using electroactive biofilm (EAB) as the sensing element represents a broad-spectrum technology for early warning of biotoxicity of water samples. However, its commercial application is impeded by limited sensitivity and repeatability. Here, we proposed a layered standardized EAB (SEAB) with enriched Geobacter anodireducens SD-1 in the inner layer and self-matched outer layer. The SEAB sensors showed a 2.3 times higher sensitivity than conventional EAB acclimated directly from wastewater (WEAB). A highly repeatable response sensitivity was concentrated at 0.011 ± 0.0006 A/m2/ppm in 4 replicated batches of SEAB sensors (R2 > 0.95), highlighting their potential for reliable toxicity monitoring in practical applications. In contrast, the sensing performance of all WEAB sensors was unpredictable. SEAB also exhibited a better tolerance towards low concentration of formaldehyde, with only a 4 % loss in viability. Our findings improved the sensitivity and reproducibility of standardized MES for toxicity early warning.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesBiofilmsWater QualityGeobacterReproducibility of ResultsWastewaterWater Pollutants, ChemicalFormaldehydeElectrochemical Techniques

Stichwörter der Autor:innen

FormaldehydeMicrobial electrochemical sensorSensitivityToxicity biosensorWater quality warning

Substanzen

WastewaterWater Pollutants, ChemicalFormaldehyde

Autor:innen und Institutionen

  • MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 3…
  • Oilfield Chemicals Division, China Oilfield Services Limited (COSL), Tianjin Marine Petroleum Environmental and Reservoir Low-Damage Drilling Fluid Enterprise Key Laboratory, China. Electronic address: yanjg5@cosl.com.c…
  • School of Environmental Science and Engineering, Tianjin University, No. 35 Yaguan Road, Jinnan District, Tianjin 300350, China.

Förderung

  • Fundamental Research Funds for the Central Universities
  • NSFC
  • Ministry of Education of the People's Republic of China

Zitieren

APA

Su, H., Yan, J., Yan, X., Zhao, Q., Liao, C., Li, N., & Wang, X. (2024). Highly sensitive standardized toxicity biosensors for rapid water quality warning. Bioresource Technology. https://doi.org/10.1016/j.biortech.2024.130985

Vancouver

Su H, Yan J, Yan X, Zhao Q, Liao C, Li N, et al. Highly sensitive standardized toxicity biosensors for rapid water quality warning. Bioresource Technology. 2024. doi:10.1016/j.biortech.2024.130985

BibTeX
@article{Su2024,
  author = {Su, Huijuan and Yan, Jiaguo and Yan, Xuejun and Zhao, Qian and Liao, Chengmei and Li, Nan and Wang, Xin},
  title = {Highly sensitive standardized toxicity biosensors for rapid water quality warning},
  journal = {Bioresource Technology},
  year = {2024},
  doi = {10.1016/j.biortech.2024.130985}
}
Kostenlos starten →