EUVIMEDEUVIMED entdecken
Crossref

An open-source microphysiological system for the evaluation of cardiovascular materials and devices under controlled flow conditions

Jesús Ordoño, Carlos Aguilar Vega, Natalia Téllez Fouz, Guillermo Domínguez, Carmelo de María, Andrés Díaz Lantada, Jon Molina-Aldareguia, Mónica Echeverry-Rendón

Biomaterials Advances · 2026

DOI: 10.1016/j.bioadv.2026.214844 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomaterials Advances, 2026. Verfasst von Jesús Ordoño und 7 weiteren Autor:innen. Beteiligte Einrichtung: IMDEA Materials Institute, 28906, Getafe, Spain; Universidad Carlos III de Madrid, 28911, Leganés, Spain. Hauptthemen laut MEDLINE: Microphysiological Systems, Biocompatible Materials, Materials Testing. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: Community of Madrid, Universidad Politécnica de Madrid, IMDEA Materials Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Traditional cell-based testing methods for biomaterials and biodevices do not always recapitulate the physiological microenvironment and fluid dynamics of native tissue, particularly in cardiovascular applications and blood interactions. This study presents the engineering and experimental validation of an open-source microphysiological system for evaluating biomaterials and cardiovascular devices under controlled flow conditions. The system stands out for its simplicity and reusability, with an accessible cell culture chamber for introducing and collecting material, thereby replicating biomaterial placement or stent deployment and facilitating sample analysis. The system was validated through two sets of experiments: the first to evaluate the behavior of a degradable biomaterial under flow conditions, and the second to analyze a medical device and its interaction with cells in a dynamic environment. In the first case, magnesium discs were evaluated to understand the potential of magnesium as a biomaterial for cardiovascular applications. The degradation dynamics and corrosion behavior were systematically studied in the microphysiological device, revealing reduced precipitate deposition and pitting corrosion. In the second case, additively manufactured NiTi (nitinol) lattices, such as those used in cardiovascular stents, were studied under both static and dynamic conditions. Endothelial cells showed a differentiated phenotype when cultured under dynamic conditions, with higher expression of VEGFR2 and CD31. The presence of a NiTi lattice affected flow shear stress patterns, promoting the accumulation of cell debris in specific low-stress areas and influencing the expression of endothelial markers. Overall, the study exemplifies a versatile and user friendly in vitro testing platform that mimics the cardiovascular environment, enabling improved understanding of its interactions with biomaterials and biomedical devices and supporting biocompatibility evaluations in real life conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Microphysiological SystemsBiocompatible MaterialsMaterials TestingHumansMagnesiumAlloysStentsHuman Umbilical Vein Endothelial Cells

Stichwörter der Autor:innen

Biomaterials testingDynamic cell culture systemsHealthcare technology assessmentOpen-source medical devices

Substanzen

Biocompatible MaterialsMagnesiumAlloysnitinol

Autor:innen und Institutionen

  • IMDEA Materials Institute, 28906, Getafe, Spain; Universidad Carlos III de Madrid, 28911, Leganés, Spain.
  • Universidad Politécnica de Madrid, 28006, Madrid, Spain.
  • IMDEA Materials Institute, 28906, Getafe, Spain.
  • Research Center E. Piaggio and Department of Information Engineering, University of Pisa, 56125, Pisa, Italy.
  • IMDEA Materials Institute, 28906, Getafe, Spain; Universidad Politécnica de Madrid, 28006, Madrid, Spain.
  • IMDEA Materials Institute, 28906, Getafe, Spain. Electronic address: monica.echeverry@imdea.org.

Förderung

  • Community of Madrid
  • Universidad Politécnica de Madrid
  • IMDEA Materials Institute

Zitieren

APA

Ordoño, J., Aguilar Vega, C., Téllez Fouz, N., Domínguez, G., de María, C., Díaz Lantada, A., Molina-Aldareguia, J., & Echeverry-Rendón, M. (2026). An open-source microphysiological system for the evaluation of cardiovascular materials and devices under controlled flow conditions. Biomaterials Advances. https://doi.org/10.1016/j.bioadv.2026.214844

Vancouver

Ordoño J, Aguilar Vega C, Téllez Fouz N, Domínguez G, de María C, Díaz Lantada A, et al. An open-source microphysiological system for the evaluation of cardiovascular materials and devices under controlled flow conditions. Biomaterials Advances. 2026. doi:10.1016/j.bioadv.2026.214844

BibTeX
@article{Ordoo2026,
  author = {Ordoño, Jesús and Aguilar Vega, Carlos and Téllez Fouz, Natalia and Domínguez, Guillermo and de María, Carmelo and Díaz Lantada, Andrés and Molina-Aldareguia, Jon and Echeverry-Rendón, Mónica},
  title = {An open-source microphysiological system for the evaluation of cardiovascular materials and devices under controlled flow conditions},
  journal = {Biomaterials Advances},
  year = {2026},
  doi = {10.1016/j.bioadv.2026.214844}
}
Kostenlos starten →