Assessing the performance of the Oxford Nanopore Technologies MinION

T Laver, J Harrison, P A O'Neill, K Moore, A Farbos, K Paszkiewicz, D J Studholme

Biomolecular Detection and Quantification · 2015

DOI: 10.1016/j.bdq.2015.02.001 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomolecular Detection and Quantification, 2015. Verfasst von T Laver und 6 weiteren Autor:innen. Beteiligte Einrichtung: Biosciences, University of Exeter, Geoffrey Pope Building, Stocker Road, Exeter EX4 4QD, UK. Die Arbeit wurde bisher 505-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wellcome Trust, Biotechnology and Biological Sciences Research Council, University of Exeter Sequencing Service.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The Oxford Nanopore Technologies (ONT) MinION is a new sequencing technology that potentially offers read lengths of tens of kilobases (kb) limited only by the length of DNA molecules presented to it. The device has a low capital cost, is by far the most portable DNA sequencer available, and can produce data in real-time. It has numerous prospective applications including improving genome sequence assemblies and resolution of repeat-rich regions. Before such a technology is widely adopted, it is important to assess its performance and limitations in respect of throughput and accuracy. In this study we assessed the performance of the MinION by re-sequencing three bacterial genomes, with very different nucleotide compositions ranging from 28.6% to 70.7%; the high G + C strain was underrepresented in the sequencing reads. We estimate the error rate of the MinION (after base calling) to be 38.2%. Mean and median read lengths were 2 kb and 1 kb respectively, while the longest single read was 98 kb. The whole length of a 5 kb rRNA operon was covered by a single read. As the first nanopore-based single molecule sequencer available to researchers, the MinION is an exciting prospect; however, the current error rate limits its ability to compete with existing sequencing technologies, though we do show that MinION sequence reads can enhance contiguity of de novo assembly when used in conjunction with Illumina MiSeq data.

Schlagwörter

Stichwörter der Autor:innen

DNA sequencingMinIONNRPS, non-ribosomal peptide synthaseNanoporeONT, Oxford Nanopore Technologies

Autor:innen und Institutionen

  • Biosciences, University of Exeter, Geoffrey Pope Building, Stocker Road, Exeter EX4 4QD, UK.
  • Biosciences, University of Exeter, Geoffrey Pope Building, Stocker Road, Exeter EX4 4QD, UK; Wellcome Trust Biomedical Informatics Hub, Geoffrey Pope Building, Stocker Road, University of Exeter, Exeter EX4 4QD, UK.

Förderung

  • Wellcome Trust
  • Biotechnology and Biological Sciences Research Council
  • University of Exeter Sequencing Service

Zitieren

APA

Laver, T., Harrison, J., O'Neill, P. A., Moore, K., Farbos, A., Paszkiewicz, K., & Studholme, D. J. (2015). Assessing the performance of the Oxford Nanopore Technologies MinION. Biomolecular Detection and Quantification. https://doi.org/10.1016/j.bdq.2015.02.001

Vancouver

Laver T, Harrison J, O'Neill PA, Moore K, Farbos A, Paszkiewicz K, et al. Assessing the performance of the Oxford Nanopore Technologies MinION. Biomolecular Detection and Quantification. 2015. doi:10.1016/j.bdq.2015.02.001

BibTeX
@article{Laver2015,
  author = {Laver, T and Harrison, J and O'Neill, P A and Moore, K and Farbos, A and Paszkiewicz, K and Studholme, D J},
  title = {Assessing the performance of the Oxford Nanopore Technologies MinION},
  journal = {Biomolecular Detection and Quantification},
  year = {2015},
  doi = {10.1016/j.bdq.2015.02.001}
}
Kostenlos starten →