EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Bigger isn’t always better: Comparing system size, hydration, and software for lipid membrane analysis

F Carvalho, P Maximiano, P N Simões, M Hashemi

Biochimica et Biophysica Acta (BBA) - Biomembranes · 2026

DOI: 10.1016/j.bbamem.2026.184541 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Biochimica et Biophysica Acta (BBA) - Biomembranes, 2026. Verfasst von F Carvalho und 3 weiteren Autor:innen. Beteiligte Einrichtung: University of Coimbra, CERES, Department of Chemical Engineering, Rua Sílvio de Lima, Coimbra, 3030-790, Portugal. Hauptthemen laut MEDLINE: Lipid Bilayers, Software, Membrane Lipids. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Foundation for Science and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The structural and dynamic properties of lipid membranes vary with bilayer size and hydration. While Molecular Dynamics (MD) simulations are a powerful tool for studying cellular membranes, results can be sensitive to the analysis workflow and software. In this study, all-atom MD simulations were conducted on 128, 256, 512, and 1024 POPC lipids at 40, 80, and 160 water molecules per lipid. A two-fold study was performed: (1) to assess the convergence of structural and dynamic properties of POPC bilayers as a function of membrane size and hydration level, including area per lipid (APL), bilayer thickness, order parameter, headgroup orientation, and lateral diffusion, and (2) to compare the performance of four software packages: CPPTRAJ (CPP), GROMACS (GRO), MDAnalysis (MDA), and LiPyphilic (LiP). For the first objective, the average APL, bilayer thickness, order parameter, and headgroup orientation were largely independent of size and hydration, whereas the lateral diffusion coefficient was sensitive to both. Notably, 128-lipid systems were susceptible to artificially inflated lateral diffusion due to finite-size artifacts at higher hydration levels. Increasing system size primarily decreased the statistical variance of APL and thickness. For the second objective, all four packages produced consistent results for APL and thickness, with the main discrepancy being a known artifact of the gmx order tool applied to unsaturated carbons. CPP was the fastest serial tool, whereas parallelization benefited MDA and LiP for some metrics. These findings demonstrate that moderately sized systems (e.g., 256L), combined with CPP, offer an efficient workflow for membrane structural property analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lipid BilayersSoftwareMembrane LipidsMolecular Dynamics SimulationWaterPhosphatidylcholinesDiffusion

Stichwörter der Autor:innen

Lipid bilayerLipid hydrationMembrane propertiesMolecular dynamics simulationsSoftware benchmark

Substanzen

Lipid BilayersWaterPhosphatidylcholines1-palmitoyl-2-oleoylphosphatidylcholineMembrane Lipids

Autor:innen und Institutionen

  • University of Coimbra, CERES, Department of Chemical Engineering, Rua Sílvio de Lima, Coimbra, 3030-790, Portugal.
  • Department of Physics, Auburn University, Leach Science Center 3126, Auburn, AL, 36849-5319, USA.
  • University of Coimbra, CERES, Department of Chemical Engineering, Rua Sílvio de Lima, Coimbra, 3030-790, Portugal. Electronic address: pnsim@eq.uc.pt.
  • Department of Physics, Auburn University, Leach Science Center 3126, Auburn, AL, 36849-5319, USA. Electronic address: hashemi@auburn.edu.

Förderung

  • Foundation for Science and Technology

Zitieren

APA

Carvalho, F., Maximiano, P., Simões, P. N., & Hashemi, M. (2026). Bigger isn’t always better: Comparing system size, hydration, and software for lipid membrane analysis. Biochimica et Biophysica Acta (BBA) - Biomembranes. https://doi.org/10.1016/j.bbamem.2026.184541

Vancouver

Carvalho F, Maximiano P, Simões PN, Hashemi M. Bigger isn’t always better: Comparing system size, hydration, and software for lipid membrane analysis. Biochimica et Biophysica Acta (BBA) - Biomembranes. 2026. doi:10.1016/j.bbamem.2026.184541

BibTeX
@article{Carvalho2026,
  author = {Carvalho, F and Maximiano, P and Simões, P N and Hashemi, M},
  title = {Bigger isn’t always better: Comparing system size, hydration, and software for lipid membrane analysis},
  journal = {Biochimica et Biophysica Acta (BBA) - Biomembranes},
  year = {2026},
  doi = {10.1016/j.bbamem.2026.184541}
}
Kostenlos starten →