Hemodynamic Differences Associated with Extreme Versus Minimal Proximal Neck Angulation in Ruptured Infrarenal Abdominal Aortic Aneurysms: A Patient-Specific Computational Study
Annals of Vascular Surgery · 2026-12 · 133 · 751-763
DOI: 10.1016/j.avsg.2026.08.013 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Annals of Vascular Surgery, 2026-12. Verfasst von Ruchen Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Vascular Surgery, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China; Medical Integra…. Hauptthemen laut MEDLINE: Aortic Aneurysm, Abdominal, Hemodynamics, Aortic Rupture, Patient-Specific Modeling. Die Arbeit nennt 29 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Maximum aneurysm diameter remains the principal criterion for abdominal aortic aneurysm (AAA) risk assessment, but additional morphologic and biomechanical factors may help explain the heterogeneity of rupture-related vulnerability. This exploratory study aimed to characterize hemodynamic differences associated with extreme versus minimal proximal neck angulation in ruptured infrarenal AAAs. METHODS: Preoperative computed tomography angiography datasets from six patients with ruptured infrarenal AAAs were retrospectively analyzed. Cases were categorized into an extreme angulation group (70° < β < 90°, n = 3) and a minimal angulation group (β < 5°, n = 3). Patient-specific computational fluid dynamics models were reconstructed to compare intrasac flow pattern, wall pressure distribution, and wall shear stress (WSS). RESULTS: Compared with minimal angulation, extreme proximal neck angulation was associated with more disturbed intrasac flow, greater flow acceleration at the neck-sac junction, and more heterogeneous wall pressure and WSS distributions. Minimally angulated aneurysms showed relatively laminar flow, whereas severely angulated aneurysms demonstrated more prominent recirculation and flow disorder. Regions of abnormal hemodynamic behavior showed qualitative spatial concordance with clinically identified rupture sites. CONCLUSION: In this small exploratory series of ruptured infrarenal AAAs, extreme proximal neck angulation was associated with a more adverse intrasac hemodynamic environment than minimal angulation. These findings are descriptive and hypothesis-generating, do not establish reproducible hemodynamic patterns or rupture risk prediction, and require validation in larger, preferably multicenter, comparative studies including both ruptured and intact AAAs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Vascular Surgery, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China; Medical Integration and Practice Center, Cheeloo College of Medicine, Shandong Univer…
- Department of Vascular Surgery, Shandong First Medical University, Jinan, Shandong, China.
- Department of Vascular Surgery, Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China.
Zitieren
APA
Li, R., Song, Q., Wang, X., Wang, J., & Wu, X. (2026). Hemodynamic Differences Associated with Extreme Versus Minimal Proximal Neck Angulation in Ruptured Infrarenal Abdominal Aortic Aneurysms: A Patient-Specific Computational Study. Annals of Vascular Surgery, 133, 751-763. https://doi.org/10.1016/j.avsg.2026.08.013
Vancouver
Li R, Song Q, Wang X, Wang J, Wu X. Hemodynamic Differences Associated with Extreme Versus Minimal Proximal Neck Angulation in Ruptured Infrarenal Abdominal Aortic Aneurysms: A Patient-Specific Computational Study. Annals of Vascular Surgery. 2026;133:751-763. doi:10.1016/j.avsg.2026.08.013
BibTeX
@article{Li2026,
author = {Li, Ruchen and Song, Qingpeng and Wang, Xiaohan and Wang, Jiacheng and Wu, Xuejun},
title = {Hemodynamic Differences Associated with Extreme Versus Minimal Proximal Neck Angulation in Ruptured Infrarenal Abdominal Aortic Aneurysms: A Patient-Specific Computational Study},
journal = {Annals of Vascular Surgery},
year = {2026},
volume = {133},
pages = {751--763},
doi = {10.1016/j.avsg.2026.08.013}
}
EUVIMED