EUVIMEDEUVIMED entdecken
Open Access

Thoracic Endovascular Aortic RepairAcutely Augments Left Ventricular Biomechanics in An Animal Model: A Mechanism for Postoperative Heart Failure and Hypertension

David P Stonko, Joseph Edwards, Hossam Abdou, Rebecca N Treffalls, Patrick Walker, Randall R DeMartino, Bernardo C Mendes, Caitlin W Hicks, Jonathan J Morrison

Annals of Vascular Surgery · 2023-11 · 97 · 18-26

DOI: 10.1016/j.avsg.2023.04.007 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Vascular Surgery, 2023-11. Verfasst von David P Stonko und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, The Johns Hopkins Hospital, Baltimore, MD; R. Adams Cowley Shock Trauma Center, University of Maryland, Baltimore, MD. Hauptthemen laut MEDLINE: Aortic Aneurysm, Thoracic, Endovascular Procedures, Hypertension, Heart Failure. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIDDK NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Thoracic aortic stent grafts are thought to decrease aortic compliance and may contribute to hypertension and heart failure after thoracic endovascular aortic repair (TEVAR). Left ventricular (LV) biomechanics immediately after TEVAR, however, have not been quantified. Pressure-volume (PV) loop analysis provides gold-standard LV functional information. The aim of this study is to use an LV PV loop catheter and analysis to characterize the LV biomechanics before and acutely after TEVAR. METHODS: Anesthetized Yorkshire swine (N = 6) were percutaneously instrumented with an LV PV loop catheter. A 20 mm × 10 cm stent graft was deployed distal to the left subclavian via the femoral artery under fluoroscopy. Cardiac biomechanics were assessed before and after TEVAR. As a sensitivity analysis, inferior vena cava occlusion with PV loop assessment was performed pre and post-TEVAR in 1 animal to obtain preload and afterload-independent end-systolic and end-diastolic PV relationships (ESPVR and EDPVR). RESULTS: All animals underwent successful instrumentation and TEVAR. Post-TEVAR, all 6 animals had higher mean LV ESP (106 vs. 118 mm Hg, P = 0.04), with no change in the EDPVR. inferior vena cava occlusion also moved the ESPVR curve upward and leftward, indicating increased LV work per unit time. There was no augmentation of EDPVR following TEVAR (P > 0.05). Postmortem exams in all animals revealed appropriate stent placement and no technical complications. CONCLUSIONS: TEVAR was associated with an acute increase in LV end-systolic pressure and shift in the ESPVR, indicating increased ventricular work. This data provides potential mechanistic insights into the development of post-TEVAR hypertension and heart failure. Future stent graft innovation should focus on minimizing the changes in cardiac physiology.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic Aneurysm, ThoracicEndovascular ProceduresHypertensionHeart FailureBlood Vessel Prosthesis ImplantationSwineAnimalsBiomechanical PhenomenaTreatment OutcomeAorta, ThoracicStentsRetrospective StudiesBlood Vessel Prosthesis

Autor:innen und Institutionen

  • Department of Surgery, The Johns Hopkins Hospital, Baltimore, MD; R. Adams Cowley Shock Trauma Center, University of Maryland, Baltimore, MD.
  • R. Adams Cowley Shock Trauma Center, University of Maryland, Baltimore, MD.
  • Divison of Vascular and Endovascular Surgery, Mayo Clinic, Rochester, MN.
  • Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, The Johns Hopkins Hospital, Baltimore, MD.
  • Divison of Vascular and Endovascular Surgery, Mayo Clinic, Rochester, MN. Electronic address: morrison.jonathan@mayo.edu.

Förderung

  • NIDDK NIH HHS

Zitieren

APA

Stonko, D. P., Edwards, J., Abdou, H., Treffalls, R. N., Walker, P., DeMartino, R. R., Mendes, B. C., Hicks, C. W., & Morrison, J. J. (2023). Thoracic Endovascular Aortic RepairAcutely Augments Left Ventricular Biomechanics in An Animal Model: A Mechanism for Postoperative Heart Failure and Hypertension. Annals of Vascular Surgery, 97, 18-26. https://doi.org/10.1016/j.avsg.2023.04.007

Vancouver

Stonko DP, Edwards J, Abdou H, Treffalls RN, Walker P, DeMartino RR, et al. Thoracic Endovascular Aortic RepairAcutely Augments Left Ventricular Biomechanics in An Animal Model: A Mechanism for Postoperative Heart Failure and Hypertension. Annals of Vascular Surgery. 2023;97:18-26. doi:10.1016/j.avsg.2023.04.007

BibTeX
@article{Stonko2023,
  author = {Stonko, David P and Edwards, Joseph and Abdou, Hossam and Treffalls, Rebecca N and Walker, Patrick and DeMartino, Randall R and Mendes, Bernardo C and Hicks, Caitlin W and Morrison, Jonathan J},
  title = {Thoracic Endovascular Aortic RepairAcutely Augments Left Ventricular Biomechanics in An Animal Model: A Mechanism for Postoperative Heart Failure and Hypertension},
  journal = {Annals of Vascular Surgery},
  year = {2023},
  volume = {97},
  pages = {18--26},
  doi = {10.1016/j.avsg.2023.04.007}
}
Kostenlos starten →