Fate and Consequences of the False Lumen After Thoracic Endovascular Aortic Repair in Type B Aortic Dissection
Annals of Vascular Surgery · 2023-08 · 94 · 32-37
DOI: 10.1016/j.avsg.2022.09.042 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Annals of Vascular Surgery, 2023-08. Verfasst von Matti Jubouri und 6 weiteren Autor:innen. Beteiligte Einrichtung: Hull York Medical School, University of York, York, UK. Hauptthemen laut MEDLINE: Aortic Aneurysm, Thoracic, Blood Vessel Prosthesis Implantation, Aortic Dissection, Endovascular Procedures. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: Royal Society, Japan Society for the Promotion of Science.
Abstract (Originalsprache)
BACKGROUND: Type B aortic dissection (TBAD) occurs due to an entry tear in the intimal layer of the aorta distal to the origin of the left subclavian artery where blood enters the newly formed false lumen (FL) and extends distally or proximally to form a dissection over an indeterminate length of the aorta which, over time, may eventually rupture. Thoracic endovascular aortic repair (TEVAR) aims to seal off the entry tear proximally with the stent-graft, occluding the origin of the dissection and excluding the FL. Nevertheless, in some cases, the perfusion to the FL is maintained, hindering the aortic remodelling process and increasing the risk of aneurysmal degeneration and rupture, particularly in the abdominal aorta where evidence suggest that remodelling is slower. This review examines the long-term effects of a patent or partially thrombosed FL on clinical outcomes following TEVAR in TBAD, also highlighting the pathological processes behind negative aortic remodelling. Another aim of this review is to provide an overview and appraisal of the currently available techniques for managing a patent or partially thrombosed FL to prevent long-term morbidity occurring. METHODS: A comprehensive literature search was performed using several search engines including PubMed, Ovid, Google Scholar, Scopus, and Embase to identify and extract relevant studies. RESULTS: Evidence in the literature show that a partially thrombosed FL is more dangerous than a patent FL due to the occlusion of the distal re-entry tears, impeding outflow and increasing mean arterial and diastolic pressures, whereas the latter is decompressed via distal re-entry sites. FL thrombosis and satisfactory remodelling is sometimes achieved in as few as 40% of patients after TEVAR due to the maintained perfusion of the FL either at the level of the thoracic or abdominal aorta. However, although the thoracic aorta is predominantly covered by the TEVAR stent-graft, poorer remodelling and more dilation is seen in the abdominal aorta. Several techniques are available to embolize the FL, including the Provisional Extension to Induce Complete Attachment, Stent Assisted Balloon Induced Intimal Disruption and Relamination in Aortic Dissection Repair, candy-plug, and Knickerbocker techniques. CONCLUSIONS: The management of TBAD is invariably TEVAR to seal off the proximal entry tear while extending the repair distally to completely exclude the FL. A risk of aortic wall dilatation distal to TEVAR stent-graft remains; hence, regular monitoring and accurate imaging are essential. At present, a patent FL can be treated using a range of different endovascular techniques.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Hull York Medical School, University of York, York, UK.
- Department of Trauma and Orthopaedics, Shrewsbury and Telford Hospital NHS Trust, Shrewsbury, UK.
- Barts and The London School of Medicine and Dentistry, Queen Mary University of London, London, UK.
- Faculty of Medicine, Al-Quds University, Jerusalem, Palestine.
- Vascular and Endovascular Surgery, Velindre University NHS Trust, Health Education and Improvement Wales (HEIW), Cardiff, UK. Electronic address: drmobashir@outlook.com.
- Neurovascular Research Laboratory, Faculty of Life Sciences and Education, University of South Wales, Pontypridd, UK.
Förderung
- Royal Society
- Japan Society for the Promotion of Science
Zitieren
APA
Jubouri, M., Patel, R., Tan, S. Z., Al-Tawil, M., Bashir, M., Bailey, D. M., & Williams, I. M. (2023). Fate and Consequences of the False Lumen After Thoracic Endovascular Aortic Repair in Type B Aortic Dissection. Annals of Vascular Surgery, 94, 32-37. https://doi.org/10.1016/j.avsg.2022.09.042
Vancouver
Jubouri M, Patel R, Tan SZ, Al-Tawil M, Bashir M, Bailey DM, et al. Fate and Consequences of the False Lumen After Thoracic Endovascular Aortic Repair in Type B Aortic Dissection. Annals of Vascular Surgery. 2023;94:32-37. doi:10.1016/j.avsg.2022.09.042
BibTeX
@article{Jubouri2023,
author = {Jubouri, Matti and Patel, Ravi and Tan, Sven Zcp and Al-Tawil, Mohammed and Bashir, Mohamad and Bailey, Damian M and Williams, Ian M},
title = {Fate and Consequences of the False Lumen After Thoracic Endovascular Aortic Repair in Type B Aortic Dissection},
journal = {Annals of Vascular Surgery},
year = {2023},
volume = {94},
pages = {32--37},
doi = {10.1016/j.avsg.2022.09.042}
}
EUVIMED