EUVIMEDEUVIMED entdecken
KohortenstudieOpen Access · CC BY 4.0

Adverse events associated with umbilical vascular catheters in the neonatal intensive care unit: A retrospective cohort study

Kim Gibson, Amber Smith, Rebecca Sharp, Amanda Ullman, Scott Morris, Adrian Esterman

Australian Critical Care · 2024

DOI: 10.1016/j.aucc.2024.01.013 ↗

Kurz gefasst

Kohortenstudie in der Zeitschrift Australian Critical Care, 2024. Verfasst von Kim Gibson und 5 weiteren Autor:innen. Beteiligte Einrichtung: Clinical and Health Sciences, Rosemary Bryant AO Research Centre, University of South Australia, Adelaide, SA, Australia. Electronic address: kim.gib…. Hauptthemen laut MEDLINE: Intensive Care Units, Neonatal, Umbilical Veins. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Umbilical catheters are commonly inserted in newborns in the neonatal intensive care unit (NICU) yet are associated with serious adverse events (AEs) such as malposition, migration, infection, thrombosis, hepatic complications, cardiac effusion, and cardiac tamponade. There is a need to determine the incidence and risk factors for AEs to inform safe practice. OBJECTIVES: The objective of this study was to determine the incidence and risk factors for AEs (all-cause and individual types) associated with umbilical venous catheters (UVCs) and umbilical arterial catheters (UACs) in the NICU. METHODS: A retrospective cohort study was conducted in an Australian level-VI NICU over a 3-year period. Any newborn who had both a UVC and UAC insertion attempt was included. RESULTS: There were 236 neonates who had 494 catheters (245 UVCs and 249 UACs). Of these, 71% of UVCs (95% confidence interval [CI]: 65.6-76.9%; incidence rate: 181.1-237.3 per 1000 catheter days) and 43.8% of UACs (95% CI: 38-50.5%; incidence rate: 102.0-146.3 per 1000 catheter days) were associated with an AE. The most common AE was malposition on first X-ray for UVCs (60.1%, 95% CI: 55.1-67.3) and UACs (32.6%, 95% CI: 26.8-39.6). A dwell time of ≥7 days was a significant predictor of UAC failure (incidence risk ratio: 1.5, 95% CI: 1.1-2.1, p = 0.006) and migration of the UVC (incidence risk ratio: 3.5, 95% CI: 1.0-11.5, p = 0.043). CONCLUSION: Adverse events related to insertion occurred in a relatively high percentage of umbilical catheters placed. Increased dwell time remains a significant risk factor for catheter migration and overall failure. Practice change and consideration of risk factors for both individual and overall AE risk are necessary to reduce complications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intensive Care Units, NeonatalUmbilical VeinsHumansRetrospective StudiesInfant, NewbornFemaleMaleRisk FactorsIncidenceUmbilical ArteriesAustraliaCatheterization, Peripheral

Stichwörter der Autor:innen

CatheterisationCentral venousInfantNeonateNewbornUmbilical arterial catheterUmbilical venous catheter

Autor:innen und Institutionen

  • Clinical and Health Sciences, Rosemary Bryant AO Research Centre, University of South Australia, Adelaide, SA, Australia. Electronic address: kim.gibson@unisa.edu.au.
  • Neonatal Unit, Flinders Medical Centre, Bedford Park, SA, Australia.
  • Clinical and Health Sciences, Rosemary Bryant AO Research Centre, University of South Australia, Adelaide, SA, Australia. Electronic address: Rebecca.sharp@unisa.edu.au.
  • School of Nursing, Midwifery and Social Work, The University of Queensland, Brisbane, QLD, Australia.
  • Allied Health & Human Performance, University of South Australia, Adelaide, SA, Australia. Electronic address: Adrian.Esterman@unisa.edu.au.

Zitieren

APA

Gibson, K., Smith, A., Sharp, R., Ullman, A., Morris, S., & Esterman, A. (2024). Adverse events associated with umbilical vascular catheters in the neonatal intensive care unit: A retrospective cohort study. Australian Critical Care. https://doi.org/10.1016/j.aucc.2024.01.013

Vancouver

Gibson K, Smith A, Sharp R, Ullman A, Morris S, Esterman A. Adverse events associated with umbilical vascular catheters in the neonatal intensive care unit: A retrospective cohort study. Australian Critical Care. 2024. doi:10.1016/j.aucc.2024.01.013

BibTeX
@article{Gibson2024,
  author = {Gibson, Kim and Smith, Amber and Sharp, Rebecca and Ullman, Amanda and Morris, Scott and Esterman, Adrian},
  title = {Adverse events associated with umbilical vascular catheters in the neonatal intensive care unit: A retrospective cohort study},
  journal = {Australian Critical Care},
  year = {2024},
  doi = {10.1016/j.aucc.2024.01.013}
}
Kostenlos starten →