Accuracy of tidal volume delivery by paediatric intensive care ventilators: A bench-model study

Meryl Vedrenne-Cloquet, Samuel Tuffet, Bruno Louis, Sonia Khirani, Charlotte Collignon, Sylvain Renolleau, Brigitte Fauroux, Guillaume Carteaux

Australian Critical Care · 2024

DOI: 10.1016/j.aucc.2023.12.007 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Australian Critical Care, 2024. Verfasst von Meryl Vedrenne-Cloquet und 7 weiteren Autor:innen. Beteiligte Einrichtung: Pediatric Sleep and Noninvasive Ventilation Unit, EA 7330 VIFASOM, AP-HP, Hôpital Necker Enfants-Malades, Paris, France; Université de Paris, Paris, …. Hauptthemen laut MEDLINE: Tidal Volume, Ventilators, Mechanical. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Tidal volume (Vt) delivery during mechanical ventilation is influenced by gas compression, humidity, and temperature. OBJECTIVES: This bench study aimed at assessing the accuracy of Vt delivery by paediatric intensive care ventilators according to the humidification system. Secondary objectives were to assess the following: (i) the accuracy of Vt delivery in ventilators with an integrated Y-piece pneumotachograph and (ii) the ability of ventilators to deliver and maintain a preset positive end-expiratory pressure. METHODS: Six latest-generation intensive care ventilators equipped with a paediatric mode were tested on the ASL5000 test lung in four simulated paediatric bench models (full-term neonate, infant, preschool-age chile, and school-age child), under volume-controlled mode with a heated humidifier (HH) or a heat moisture exchanger, with various loading conditions. Three ventilators equipped with a Y-piece pneumotachograph were tested with or without the pneumotachograph in the neonatal and infant models. "Accurate Vt" delivery was defined as a volume error (percentage of the preset Vt under body temperature and pressure and saturated water vapour conditions) being ≤10 % of the absolute preset value. RESULTS: Vt accuracy varied significantly across ventilators but was acceptable in almost all the ventilators and all the models, except the neonatal model. The humidification system had an impact on Vt delivery in the majority of the tested conditions (p < 0.05). The use of an HH was associated with a better Vt accuracy in four ventilators (V500, V800, R860, and ServoU) and allowed to achieve an acceptable level of volume error in the neonatal model as compared to the use of heat moisture exchanger. The use of an integrated pneumotachograph was associated with lower volume error in only one ventilator (p < 0.01). All the tested ventilators were able to maintain adequate positive end-expiratory pressure levels. CONCLUSION: The humidification system affects Vt accuracy of paediatric intensive care ventilators, especially in the youngest patients for whom the HH should be preferred.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tidal VolumeVentilators, MechanicalHumansInfant, NewbornInfantEquipment DesignRespiration, ArtificialChildIntensive Care Units, PediatricChild, PreschoolHumidity

Stichwörter der Autor:innen

Bench studyHeat moisture exchangerHeated humidifierPaediatric intensive care unitVolume-controlled ventilation

Autor:innen und Institutionen

  • Pediatric Sleep and Noninvasive Ventilation Unit, EA 7330 VIFASOM, AP-HP, Hôpital Necker Enfants-Malades, Paris, France; Université de Paris, Paris, France; Réanimation Médicochirurgicale Pédiatrique, AP-HP, CHU Necker-…
  • INSERM, Université Paris Est Créteil IMRB, CNRS EMR, 7000, Créteil, France; GRC CARMAS, IMRB, Université Paris Est Créteil, Faculté de Santé de Créteil, Créteil, France; Réanimation Médicale, AP-HP, Centre Hospitalier U…
  • INSERM, Université Paris Est Créteil IMRB, CNRS EMR, 7000, Créteil, France.
  • Pediatric Sleep and Noninvasive Ventilation Unit, EA 7330 VIFASOM, AP-HP, Hôpital Necker Enfants-Malades, Paris, France; Université de Paris, Paris, France; ASV Santé, Gennevilliers, France.
  • Réanimation Médicochirurgicale Pédiatrique, AP-HP, CHU Necker-Enfants Malades, Paris, France.
  • Université de Paris, Paris, France; Réanimation Médicochirurgicale Pédiatrique, AP-HP, CHU Necker-Enfants Malades, Paris, France.

Zitieren

APA

Vedrenne-Cloquet, M., Tuffet, S., Louis, B., Khirani, S., Collignon, C., Renolleau, S., Fauroux, B., & Carteaux, G. (2024). Accuracy of tidal volume delivery by paediatric intensive care ventilators: A bench-model study. Australian Critical Care. https://doi.org/10.1016/j.aucc.2023.12.007

Vancouver

Vedrenne-Cloquet M, Tuffet S, Louis B, Khirani S, Collignon C, Renolleau S, et al. Accuracy of tidal volume delivery by paediatric intensive care ventilators: A bench-model study. Australian Critical Care. 2024. doi:10.1016/j.aucc.2023.12.007

BibTeX
@article{VedrenneCloquet2024,
  author = {Vedrenne-Cloquet, Meryl and Tuffet, Samuel and Louis, Bruno and Khirani, Sonia and Collignon, Charlotte and Renolleau, Sylvain and Fauroux, Brigitte and Carteaux, Guillaume},
  title = {Accuracy of tidal volume delivery by paediatric intensive care ventilators: A bench-model study},
  journal = {Australian Critical Care},
  year = {2024},
  doi = {10.1016/j.aucc.2023.12.007}
}
Kostenlos starten →