Optimal suturing techniques in patch-bridging reconstruction for massive rotator cuff tears: A finite element analysis
Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology · 2025-01 · 39 · 22-29
DOI: 10.1016/j.asmart.2024.10.002 ↗Kurz gefasst
Fachartikel in der Zeitschrift Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology, 2025-01. Verfasst von Yuting Zhong und 7 weiteren Autor:innen. Beteiligte Einrichtung: Sports Medicine Institute of Fudan University, Department of Sports Medicine, Huashan Hospital, Fudan University, Shanghai, 200040, PR China. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Purpose
To use a finite element method to construct a patch-bridge repair model for massive rotator cuff tears (MRCTs) and investigate the effects of different suture methods and knot numbers on postoperative biomechanics.
Methods
A finite element model based on intact glenohumeral joint data was used for a biomechanical study. A full-thickness defect and retraction model of the supraspinatus tendon simulated MRCTs. Patch, suture, and anchor models were constructed, and the Marlow method was used to assign the material properties. Three suturing models were established: 1-knot simple, 1-knot mattress, and 2-knot mattress. The ultimate failure load, failure mode, stress distribution of each structure, and other biomechanical results of the different models were calculated and compared.
Results
The ultimate failure load of the 1-knot mattress suture (71.3 N) was 5.6 % greater than that of the 1-knot simple suture (67.5 N), while that (81.5 N) of the 2-knot mattress was 14.3 % greater than that of the 1-knot mattress. The stress distribution on the patch and supraspinatus tendon was concentrated on suture perforation. Failure of the bridging reconstruction mainly occurred at the suture perforation of the patch, and the damage forms included cutting-through and isthmus pull-out.
Conclusion
A finite element model for the patch-bridging reconstruction of MRCTs was established, and patch-bridging restored the mechanical integrity of the rotator cuff. The 2-knot mattress suture was optimal for patch-bridging reconstruction of MRCTs.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Sports Medicine Institute of Fudan University, Department of Sports Medicine, Huashan Hospital, Fudan University, Shanghai, 200040, PR China.
- Department of Orthopedic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, PR China.
- Orthopedics Research Institute of Zhejiang University, Hangzhou, Zhejiang Province, PR China.
- Key Laboratory of Motor System Disease Research and Precision Therapy of Zhejiang Province, Hangzhou, Zhejiang Province, PR China.
- Clinical Research Center of Motor System Disease of Zhejiang Province, PR China.
Zitieren
APA
Zhong, Y., Yu, C., Feng, S., Gao, H., Sun, L., Li, Y., Chen, S., & Chen, J. (2025). Optimal suturing techniques in patch-bridging reconstruction for massive rotator cuff tears: A finite element analysis. Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology, 39, 22-29. https://doi.org/10.1016/j.asmart.2024.10.002
Vancouver
Zhong Y, Yu C, Feng S, Gao H, Sun L, Li Y, et al. Optimal suturing techniques in patch-bridging reconstruction for massive rotator cuff tears: A finite element analysis. Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology. 2025;39:22-29. doi:10.1016/j.asmart.2024.10.002
BibTeX
@article{Zhong2025,
author = {Zhong, Yuting and Yu, Chengxuan and Feng, Sijia and Gao, Han and Sun, Luyi and Li, Yunxia and Chen, Shiyi and Chen, Jun},
title = {Optimal suturing techniques in patch-bridging reconstruction for massive rotator cuff tears: A finite element analysis},
journal = {Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology},
year = {2025},
volume = {39},
pages = {22--29},
doi = {10.1016/j.asmart.2024.10.002}
}
EUVIMED