EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC-ND 4.0

Suture Anchor and Reverse Suture Anchor Show Superior Biomechanical Efficacy to Transtibial Pull‐Out Repair for Posterior Medial Meniscus Root Tears in Porcine Model

Chenyang Meng, Wei Feng, Lingyue Kong, Ming Liu, Bing Leng, Fujia Kang, Yizhong Ren, Yi Qiu, Changxu Han

Arthroscopy · 2025

DOI: 10.1016/j.arthro.2025.03.013 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Arthroscopy, 2025. Verfasst von Chenyang Meng und 8 weiteren Autor:innen. Beteiligte Einrichtung: Sports Medicine Center, The Second Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia, China. Hauptthemen laut MEDLINE: Suture Anchors, Tibial Meniscus Injuries, Suture Techniques, Menisci, Tibial. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Department of Science and Technology of Inner Mongolia Autonomous Region, Inner Mongolia Medical University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To investigate the biomechanical efficacy of the reverse suture anchor (RSA) technique compared with the transtibial pull‐out (TP) and suture anchor (SA) techniques using in vitro porcine knee models of posterior medial meniscus root tear (PMMRTs).

Methods

A total of 32 fresh‐frozen porcine tibiae with medial meniscus intact were randomly assigned to 4 groups (8 specimens each). A standardized PMMRT was established in 24 specimens. SA, TP, and RSA techniques were used to repair PMMRTs in 8 specimens, respectively, while the native posterior medial meniscus roots (PMMRs) were left intact as a control in 8 specimens. Pressure sensitivity, stress, cyclic load, and failure load tests were performed. To evaluate differences in group variables, ANOVA was used to compare differences among ≥3 groups, and Tukey's test was used to compare data between 2 groups. Significance level was set at P < .05.

Results

The SA and RSA groups had a wider contact area and higher pressure at the meniscus suture site and attachment area than the TP group ( P < .001), while there was no significant difference in pressure sensitivity or stress between SA and RSA ( P > .05). The SA, RSA, and TP groups had significantly higher displacement during cyclic loading and significantly lower maximum load and stiffness during load‐to‐failure testing compared with the native PMMR ( P < .05). The SA and RSA groups had significantly lower displacement after 100 (0.83 mm and 0.92 mm vs 1.77 mm; P < .01), 500 (1.64 mm and 1.52 mm vs 3.08 mm; P < .01), and 1,000 cycles (2.22 mm and 1.91 mm vs 4.53 mm; P < .01) and significantly higher failure load compared with TP (114 N and 119 N vs 77 N; P < .01). No significant difference between SA, RSA, and TP was observed for displacement at failure or stiffness ( P > .05).

Conclusions

The RSA repair technique has similar biomechanical efficacy to the SA technique. It offers better biomechanical efficacy than the TP technique for PMMRT repair, making it a feasible and effective surgical procedure. The 3 repair techniques did not reach the strength of the native PMMR. Clinical Relevance The RSA technique retrogradely implants anchors into the tibial bone tunnels to achieve a fixation effect comparable to that of traditional anchors, with shorter sutures in the bone tunnels and a more operable surgical procedure. The RSA technique not only provides satisfactory biomechanical properties for the repair of PMMRTs but also greatly reduces the technical difficulty of surgery. However, repair of PMMRTs still does not restore the strength of the repaired meniscal root to the native meniscus.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Suture AnchorsTibial Meniscus InjuriesSuture TechniquesMenisci, TibialAnimalsSwineBiomechanical PhenomenaDisease Models, AnimalTibia

Autor:innen und Institutionen

  • Sports Medicine Center, The Second Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia, China.
  • Trauma Orthopaedic Center, The Second Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia, China.
  • Diagnostic Ultrasound Center, The Second Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia, China.
  • Anesthesia Surgical Center, The Second Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia, China.
  • Sports Medicine Center, The Second Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia, China. Electronic address: meniscus2011@163.com.

Förderung

  • Department of Science and Technology of Inner Mongolia Autonomous Region
  • Inner Mongolia Medical University

Zitieren

APA

Meng, C., Feng, W., Kong, L., Liu, M., Leng, B., Kang, F., Ren, Y., Qiu, Y., & Han, C. (2025). Suture Anchor and Reverse Suture Anchor Show Superior Biomechanical Efficacy to Transtibial Pull‐Out Repair for Posterior Medial Meniscus Root Tears in Porcine Model. Arthroscopy. https://doi.org/10.1016/j.arthro.2025.03.013

Vancouver

Meng C, Feng W, Kong L, Liu M, Leng B, Kang F, et al. Suture Anchor and Reverse Suture Anchor Show Superior Biomechanical Efficacy to Transtibial Pull‐Out Repair for Posterior Medial Meniscus Root Tears in Porcine Model. Arthroscopy. 2025. doi:10.1016/j.arthro.2025.03.013

BibTeX
@article{Meng2025,
  author = {Meng, Chenyang and Feng, Wei and Kong, Lingyue and Liu, Ming and Leng, Bing and Kang, Fujia and Ren, Yizhong and Qiu, Yi and Han, Changxu},
  title = {Suture Anchor and Reverse Suture Anchor Show Superior Biomechanical Efficacy to Transtibial Pull‐Out Repair for Posterior Medial Meniscus Root Tears in Porcine Model},
  journal = {Arthroscopy},
  year = {2025},
  doi = {10.1016/j.arthro.2025.03.013}
}
Kostenlos starten →