EUVIMEDEUVIMED entdecken
Crossref

Arthroscopic Autologous Iliac Crest Grafting With an Adjustable‐Loop Suspensory Device Yields Favorable Outcomes for Anterior Shoulder Instability With Glenoid Defects

Weilin Yu, Di Wu, Chenrui Yuan, Xiping Jiang, Yaohua He

Arthroscopy · 2025-05 · 41 (5) · 1326-1334

DOI: 10.1016/j.arthro.2024.07.035 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Arthroscopy, online erschienen am 19.08.2024. Verfasst von Weilin Yu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China. Hauptthemen laut MEDLINE: Joint Instability, Arthroscopy, Ilium, Bone Transplantation. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: Shanghai Hospital Development Center.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the clinical and radiologic outcomes of the arthroscopic autologous iliac crest grafting (AICG) procedure with an adjustable‐loop suspensory fixation device in the treatment of anterior shoulder instability with glenoid bone defects.

Methods

A retrospective review was conducted on the patients who underwent arthroscopic AICG with an adjustable‐loop suspensory fixation device from January 2017 to December 2020. Patients with traumatic anterior shoulder instability, significant glenoid bone defects, and a minimum follow‐up of 24 months were included. Patient‐reported outcomes, including the Oxford Shoulder Instability Score (OSIS), the Rowe score, the Walch‐Duplay score, the Constant score, and the visual analog scale score, were compared preoperatively and postoperatively. Radiologic assessments using computed tomography were performed before and after the procedure. Additional data on active range of motion, recurrence events, and complications were recorded.

Results

A total of 42 patients were included in the study, with a mean follow‐up time of 35.2 months, ranging from 25.1 to 55.9 months. Mean preoperative OSIS, Rowe score, Walch‐Duplay score, and Constant score significantly improved from 24.4 ± 7.2, 25.0 ± 9.0, 25.2 ± 9.8, 87.5 ± 7.1 to 42.4 ± 4.9, 92.4 ± 8.1, 87.9 ± 8.3, and 93.6 ± 4.5 at the last follow‐up, respectively. All patients exceeded the minimal clinically important difference for OSIS, Rowe, and Walch‐Duplay scores. The graft union rate was 100%, and the glenoid area increased significantly from 82.5% preoperatively to 100.1% at the final follow‐up. No patient experienced a recurrence of instability. Two recorded complications included one case of dysesthesia around the donor site and one case of postoperative shoulder stiffness.

Conclusions

The outcomes of the arthroscopic AICG procedure, which uses an adjustable‐loop suspensory fixation device, demonstrated stable bone graft fixation, high rates of graft integration, favorable clinical results, and a low incidence of complications. Moreover, the remodeling of the graft during the follow‐up period significantly restored the width and concavity of the inferior glenoid, contributing to the overall recovery. Level of Evidence Level IV, retrospective case series.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Joint InstabilityArthroscopyIliumBone TransplantationShoulder JointGlenoid CavityHumansRetrospective StudiesMaleFemaleAdultTransplantation, AutologousTreatment OutcomeMiddle AgedYoung AdultRange of Motion, Articular

Autor:innen und Institutionen

  • Department of Orthopedic Surgery, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Department of Orthopedics, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, China.
  • Department of Orthopedic Surgery, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China; Department of Orthopedic Surgery, Jinshan District Central Hospital Aff…

Förderung

  • Shanghai Hospital Development Center

Zitieren

APA

Yu, W., Wu, D., Yuan, C., Jiang, X., & He, Y. (2025). Arthroscopic Autologous Iliac Crest Grafting With an Adjustable‐Loop Suspensory Device Yields Favorable Outcomes for Anterior Shoulder Instability With Glenoid Defects. Arthroscopy, 41(5), 1326-1334. https://doi.org/10.1016/j.arthro.2024.07.035

Vancouver

Yu W, Wu D, Yuan C, Jiang X, He Y. Arthroscopic Autologous Iliac Crest Grafting With an Adjustable‐Loop Suspensory Device Yields Favorable Outcomes for Anterior Shoulder Instability With Glenoid Defects. Arthroscopy. 2025;41(5):1326-1334. doi:10.1016/j.arthro.2024.07.035

BibTeX
@article{Yu2025,
  author = {Yu, Weilin and Wu, Di and Yuan, Chenrui and Jiang, Xiping and He, Yaohua},
  title = {Arthroscopic Autologous Iliac Crest Grafting With an Adjustable‐Loop Suspensory Device Yields Favorable Outcomes for Anterior Shoulder Instability With Glenoid Defects},
  journal = {Arthroscopy},
  year = {2025},
  volume = {41},
  number = {5},
  pages = {1326--1334},
  doi = {10.1016/j.arthro.2024.07.035}
}
Kostenlos starten →