Suture Contamination During Arthroscopic Rotator Cuff Repair Is Associated With Significantly Higher Retear Rates in Magnetic Resonance Imaging: A Matched‐Pair Analysis

Chih-Kai Hong, Kai-Lan Hsu, Fa-Chuan Kuan, Yueh Chen, Ya-Ting Lee, Pei-Fang Tsai, Po-Lin Chen, Wei-Ren Su

Arthroscopy · 2024

DOI: 10.1016/j.arthro.2024.02.019 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Arthroscopy, 2024. Verfasst von Chih-Kai Hong und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan; Depa…. Hauptthemen laut MEDLINE: Arthroscopy, Magnetic Resonance Imaging, Rotator Cuff Injuries. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: National Cheng Kung University Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the correlation between suture contamination and rotator cuff tendon retear after arthroscopic rotator cuff repair.

Methods

Patients undergoing primary arthroscopic rotator cuff repair from April 1, 2020, to September 30, 2022, were enrolled. Those younger than 18 years, with a history of shoulder surgeries or shoulder infection episodes, or who declined participation were excluded. A 5‐cm section of the first‐cut suture, originating from the anchor eyelet ends, in each rotator cuff repair surgery was subjected to bacteria culture and polymerase chain reaction analysis. Patients with positive culture findings were matched 1:1 to those with negative culture reports based on age, sex, tear size as well as involved tendons, preoperative fatty infiltration grade (Goutallier grade), and preoperative muscle atrophy grade (Warner score). Postoperative rotator cuff tendon retear assessments were conducted at the 6‐month mark using the Sugaya classification via magnetic resonance imaging. The Wilcoxon signed‐rank test was used for matched‐pair comparisons between the groups.

Results

A total of 141 patients (60 men and 81 women) with a mean age of 61.0 ± 8 years were finally enrolled. Twenty‐six patients (18 men and 8 women) had a positive culture, while 115 patients (42 men and 73 women) had a negative culture. After the propensity score matching process, 24 culture‐negative patients (16 men and 8 women) were selected as the culture‐negative group. Age, fatty infiltration grade, and muscle atrophy grade were not significantly different between matched groups. The retear grade in the culture‐positive group was significantly higher than that in the culture‐negative group ( P = .020) under the matched‐pair comparison. Cutibacterium acnes was the most prevalent bacterial species responsible for suture contamination.

Conclusions

The matched‐pair analysis revealed that the presence of bacterial contamination on sutures was associated with a higher risk of retear on magnetic resonance imaging following arthroscopic rotator cuff repair. Level of Evidence Level III, retrospective cohort study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArthroscopyMagnetic Resonance ImagingRotator Cuff InjuriesHumansMaleFemaleMiddle AgedMatched-Pair AnalysisSuturesAgedSuture TechniquesRotator CuffRetrospective Studies

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan; Department of Orthopaedic Surgery, National Cheng Kung University Hospital…
  • Department of Orthopaedic Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan.
  • Department of Orthopedic Surgery, Kaohsiung Veteran General Hospital Tainan Branch, Tainan, Taiwan.
  • Department of Pathology, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan.
  • Department of Internal Medicine, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan; Center for Infection Control, National Cheng Kung University Hospital, Colle…
  • Department of Orthopaedic Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan; Musculoskeletal Research Center, Innovation Headquarter, National Cheng Ku…

Förderung

  • National Cheng Kung University Hospital

Zitieren

APA

Hong, C. K., Hsu, K. L., Kuan, F. C., Chen, Y., Lee, Y. T., Tsai, P. F., Chen, P. L., & Su, W. R. (2024). Suture Contamination During Arthroscopic Rotator Cuff Repair Is Associated With Significantly Higher Retear Rates in Magnetic Resonance Imaging: A Matched‐Pair Analysis. Arthroscopy. https://doi.org/10.1016/j.arthro.2024.02.019

Vancouver

Hong CK, Hsu KL, Kuan FC, Chen Y, Lee YT, Tsai PF, et al. Suture Contamination During Arthroscopic Rotator Cuff Repair Is Associated With Significantly Higher Retear Rates in Magnetic Resonance Imaging: A Matched‐Pair Analysis. Arthroscopy. 2024. doi:10.1016/j.arthro.2024.02.019

BibTeX
@article{Hong2024,
  author = {Hong, Chih-Kai and Hsu, Kai-Lan and Kuan, Fa-Chuan and Chen, Yueh and Lee, Ya-Ting and Tsai, Pei-Fang and Chen, Po-Lin and Su, Wei-Ren},
  title = {Suture Contamination During Arthroscopic Rotator Cuff Repair Is Associated With Significantly Higher Retear Rates in Magnetic Resonance Imaging: A Matched‐Pair Analysis},
  journal = {Arthroscopy},
  year = {2024},
  doi = {10.1016/j.arthro.2024.02.019}
}
Kostenlos starten →