Computer‐Assisted Arthroscopic Cam Resection
Arthroscopy · 2024
DOI: 10.1016/j.arthro.2024.01.015 ↗Kurz gefasst
Fachartikel in der Zeitschrift Arthroscopy, 2024. Verfasst von Thomas W Fenn und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois, U.S.A.. Electronic address: nho.research@rushortho.com. Hauptthemen laut MEDLINE: Femoracetabular Impingement. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 10 Literaturangaben.
Abstract (Originalsprache)
Determining the appropriate femoral cam resection during hip arthroscopy for femoroacetabular impingement syndrome is both critical for the patient and challenging for the surgeon. Incomplete bone resection is a leading cause of failed hip arthroscopy, whereas over‐resection may increase the risk of femoral neck fracture. The alpha angle is a validated 2‐dimensional radiographic measurement used to both diagnose femoroacetabular impingement syndrome preoperatively and to determine resection adequacy postoperatively. Computer‐assisted intraoperative guidance systems enhance the accuracy of femoral cam resection, although a preoperative 3‐dimensional computed tomography scan may be required. Other systems, such as the HipCheck software (Stryker, Kalamazoo, MI), have been developed to provide intraoperative guidance with live feedback using simultaneous alpha angle measurements overlayed on fluoroscopic images without the requirement for routine preoperative computed tomography. Via intraoperative touchscreen navigation, the surgeon identifies the midpoint of the femoral neck and femoral head. A commercial software program provides real‐time alpha angle measurements, as well as enhanced visualization of the femoral cam deformity with an adjustable resection curve. Before the surgeon performs the cam resection, the software provides a template for appropriate resection depth in 6 positions of the hip. Upon completion of the femoral cam resection, the hip is again assessed in the same 6 positions and the alpha angle is assessed to ensure a complete resection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois, U.S.A.. Electronic address: nho.research@rushortho.com.
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois, U.S.A.
Zitieren
APA
Fenn, T. W., Jan, K., Larson, J. H., Brusalis, C. M., & Nho, S. J. (2024). Computer‐Assisted Arthroscopic Cam Resection. Arthroscopy. https://doi.org/10.1016/j.arthro.2024.01.015
Vancouver
Fenn TW, Jan K, Larson JH, Brusalis CM, Nho SJ. Computer‐Assisted Arthroscopic Cam Resection. Arthroscopy. 2024. doi:10.1016/j.arthro.2024.01.015
BibTeX
@article{Fenn2024,
author = {Fenn, Thomas W and Jan, Kyleen and Larson, Jordan H and Brusalis, Christopher M and Nho, Shane J},
title = {Computer‐Assisted Arthroscopic Cam Resection},
journal = {Arthroscopy},
year = {2024},
doi = {10.1016/j.arthro.2024.01.015}
}
EUVIMED