Tape‐Reinforced Graft Suturing and Retensioning of Adjustable‐Loop Cortical Buttons Improve Quadriceps Tendon Autograft Biomechanics in Anterior Cruciate Ligament Reconstruction: A Cadaveric Study
Arthroscopy · 2024-01 · 40 (1) · 136-145
DOI: 10.1016/j.arthro.2023.06.021 ↗Kurz gefasst
Fachartikel in der Zeitschrift Arthroscopy, online erschienen am 22.06.2023. Verfasst von Joseph D Lamplot und 4 weiteren Autor:innen. Beteiligte Einrichtung: Campbell Clinic, Germantown, Tennessee, U.S.A.. Electronic address: jlamplot@campbellclinic.com. Hauptthemen laut MEDLINE: Anterior Cruciate Ligament, Anterior Cruciate Ligament Reconstruction. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 42 Literaturangaben.
Abstract (Originalsprache)
Purpose
To investigate the biomechanical effects of tape‐reinforced graft suturing and graft retensioning for all–soft tissue quadriceps tendon (ASTQT) anterior cruciate ligament reconstruction (ACLR) in a full‐construct human cadaveric model.
Methods
Harvested cadaveric ASTQT grafts were assigned to either (1) double‐suspensory adjustable‐loop cortical button device (ALD) fixation in which both graft ends were fixed with a suspensory fixation device with (n = 5) or without (n = 5) tape‐reinforced suturing or (2) single‐suspensory distal tendon fixation in which only the patellar end was fixed with an ALD (n = 5) or fixed‐loop cortical button device (FLD) (n = 5). All specimens were prepared using a No. 2 whipstitch technique, and tape‐reinforced specimens had an integrated braided tape implant. Graft preparation time was recorded for double‐suspensory constructs. Samples were tested on an electromechanical testing machine using a previously published protocol simulating rehabilitative kinematics and loading.
Results
Tape‐reinforced graft suturing resulted in greater graft load retention after cycling (11.9% difference, P = .021), less total elongation (mean [95% confidence interval (CI)], 5.57 mm [3.50‐7.65 mm] vs 32.14 mm [25.38‐38.90 mm]; P < .001), greater ultimate failure stiffness (mean [95% CI], 171.9 N/mm [158.8‐185.0 N/mm] vs 119.4 N/mm [108.7‐130.0 N/mm]; P < .001), and less graft preparation time (36.4% difference, P < .001) when compared with unreinforced specimens. Retensioned ALD constructs had less cyclic elongation compared with FLD constructs (mean total elongation [95% CI], 7.04 mm [5.47‐8.61 mm] vs 12.96 mm [8.67‐17.26 mm]; P = .004).
Conclusions
Tape‐reinforced graft suturing improves time‐zero ASTQT ACLR construct biomechanics in a cadaveric model with 83% less total elongation, 44% greater stiffness, and reduced preparation time compared with a whipstitched graft without tape reinforcement. ALD fixation improves construct mechanics when compared with FLD fixation as evidenced by 46% less total elongation. Clinical Relevance Tape‐reinforced implants and graft retensioning using ALDs improve time‐zero ACLR graft construct biomechanics in a time‐zero biomechanical model. Clinical studies will be necessary to determine whether these implants improve clinical outcomes including knee laxity and the incidence of graft rupture.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Campbell Clinic, Germantown, Tennessee, U.S.A.. Electronic address: jlamplot@campbellclinic.com.
- Department of Orthopedic Research, Arthrex, Naples, Florida, U.S.A.
- Department of Orthopedic Surgery, Medical University of South Carolina, Charleston, South Carolina, U.S.A.
Zitieren
APA
Lamplot, J. D., Smith, B. L., Slone, H. S., Hauck, O. L., & Wijdicks, C. A. (2024). Tape‐Reinforced Graft Suturing and Retensioning of Adjustable‐Loop Cortical Buttons Improve Quadriceps Tendon Autograft Biomechanics in Anterior Cruciate Ligament Reconstruction: A Cadaveric Study. Arthroscopy, 40(1), 136-145. https://doi.org/10.1016/j.arthro.2023.06.021
Vancouver
Lamplot JD, Smith BL, Slone HS, Hauck OL, Wijdicks CA. Tape‐Reinforced Graft Suturing and Retensioning of Adjustable‐Loop Cortical Buttons Improve Quadriceps Tendon Autograft Biomechanics in Anterior Cruciate Ligament Reconstruction: A Cadaveric Study. Arthroscopy. 2024;40(1):136-145. doi:10.1016/j.arthro.2023.06.021
BibTeX
@article{Lamplot2024,
author = {Lamplot, Joseph D and Smith, Benjamin L and Slone, Harris S and Hauck, Oliver L and Wijdicks, Coen A},
title = {Tape‐Reinforced Graft Suturing and Retensioning of Adjustable‐Loop Cortical Buttons Improve Quadriceps Tendon Autograft Biomechanics in Anterior Cruciate Ligament Reconstruction: A Cadaveric Study},
journal = {Arthroscopy},
year = {2024},
volume = {40},
number = {1},
pages = {136--145},
doi = {10.1016/j.arthro.2023.06.021}
}
EUVIMED