EUVIMEDEUVIMED entdecken
Crossref

Complications of Ceramic-on-Ceramic Total Hip Arthroplasty With Large Heads: 10-Year Minimum Follow-Up

Dong-Hoon Lee, Jung-Wee Park, Woon-Hwa Jung, Tae-Young Kim, Yong-Chan Ha, Kyung-Hoi Koo, Young-Kyun Lee

The Journal of Arthroplasty · 2026-06

DOI: 10.1016/j.arth.2026.06.015 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2026-06. Verfasst von Dong-Hoon Lee und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Chung-Ang University Gwangmyeong Hospital, Gwangmyeong, South Korea. Die Arbeit nennt 61 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND The fourth-generation ceramic bearings allow the use of larger femoral heads, but inevitably create thinner liners, raising concerns regarding liner fracture and long-term biological responses. We extended our study to evaluate late dislocation, ceramic-related complications, and long-term clinical and radiographic outcomes more than 10 years after ceramic-on-ceramic (CoC) total hip arthroplasty (THA). METHODS We conducted a prospective multicenter study of cementless THA using a 32/36-mm ceramic bearing. From April 2010 to February 2012, 246 patients (274 THAs) were enrolled. We evaluated ceramic fracture, noise, clinical results, radiological changes, and survival rate at a minimum of 10-year follow-up. In this study, 178 patients (100 men and 78 women, 201 hips) who had a mean age of 51 years (range, 18.9 to 77.6) at surgery were followed for a mean of 12.3 years (range, 10 to 14.6) with computed tomography (CT) scans in 47 hips (23%, 47 of 201). Kaplan-Meier survival analysis was performed with revision and reoperation as endpoints. RESULTS In addition to previously reported three dislocations, the new one sustained anterior instability due to lumbar degenerative kyphosis (LDK) associated with posterior impingement. Ceramic fracture did not occur in any patient. The mean Harris Hip Score was 87.0 ± 11.5 points at the latest follow-up. New focal osteolysis was detected in one hip (0.5%). Articular noise was reported in 11 hips (5.5%). The survival rate for revision surgery was 99.1% (95% confidence interval (CI), 97.9 to 100.0), and any operation was 98.7% (95% CI, 97.2 to 100.0) at 12 years postoperatively. CONCLUSION Our findings revealed that a large head CoC bearing could prevent early dislocation without any risk of liner fracture even in a thinner ceramic liner. However, there might still be concern of LDK-associated late instability and noise even with a large head in long-term follow-up.

Schlagwörter

Stichwörter der Autor:innen

Delta ceramicceramic-on-ceramic bearingcomplicationslarge headlate dislocationtotal hip arthroplasty

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Chung-Ang University Gwangmyeong Hospital, Gwangmyeong, South Korea.
  • Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea; Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul, South Korea.
  • Department of Orthopaedic Surgery, Murup Hospital, Masan, South Korea.
  • Department of Orthopaedic Surgery, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, South Korea.
  • Department of Orthopedic Surgery, Seoul Bumin Hospital, Seoul, South Korea.
  • Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea; Kay Joint Center, Cheil Orthopedic Hospital, Seoul, South Korea.

Zitieren

APA

Lee, D. H., Park, J. W., Jung, W. H., Kim, T. Y., Ha, Y. C., Koo, K. H., & Lee, Y. K. (2026). Complications of Ceramic-on-Ceramic Total Hip Arthroplasty With Large Heads: 10-Year Minimum Follow-Up. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2026.06.015

Vancouver

Lee DH, Park JW, Jung WH, Kim TY, Ha YC, Koo KH, et al. Complications of Ceramic-on-Ceramic Total Hip Arthroplasty With Large Heads: 10-Year Minimum Follow-Up. The Journal of Arthroplasty. 2026. doi:10.1016/j.arth.2026.06.015

BibTeX
@article{Lee2026,
  author = {Lee, Dong-Hoon and Park, Jung-Wee and Jung, Woon-Hwa and Kim, Tae-Young and Ha, Yong-Chan and Koo, Kyung-Hoi and Lee, Young-Kyun},
  title = {Complications of Ceramic-on-Ceramic Total Hip Arthroplasty With Large Heads: 10-Year Minimum Follow-Up},
  journal = {The Journal of Arthroplasty},
  year = {2026},
  doi = {10.1016/j.arth.2026.06.015}
}
Kostenlos starten →