Cemented Femoral Stem Design Is Not Associated With Differences in All-Cause Revision or Specific Failure Modes After Total Hip Arthroplasty for Femoral Neck Fracture

Charles A Gusho, Wayne Hoskins, Connor Riley, Mackenzie Kelly, Vishal Hegde, Ryland Kagan, Elie S Ghanem

The Journal of Arthroplasty · 2026

DOI: 10.1016/j.arth.2026.05.055 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2026. Verfasst von Charles A Gusho und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, University of Missouri, Columbia, Missouri. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Reoperation, Femoral Neck Fractures, Hip Prosthesis. Die Arbeit nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Cemented stem fixation in total hip arthroplasty (THA) for femoral neck fracture (FNF) has increased in utilization. Cemented stems reduce the periprosthetic fracture risk compared to cementless fixation, but it is unclear whether revision varies by stem design in this cohort. We compared taper-slip versus composite beam cemented stems among FNF patients undergoing THA using a modern classification system. METHODS: Patients ≥ 65 years of age undergoing primary THA for FNF between 2012 and 2021 with a minimum 2-year follow-up were screened within the American Joint Replacement Registry. A total of 3,479 cases (mean [standard deviation] with follow-ups of 78.8 months (28.3)) met inclusion. The primary analysis compared all-cause and 90-day revision between taper slip (n = 599; 17.2%) and composite beam (n = 2,880; 82.8%) stems. The secondary analyses compared revision for aseptic loosening, fracture, infection, dislocation, and mortality. Cox proportional regressions with competing risks of death evaluated the association of revision with stem design when adjusted for confounders. RESULTS: Taper-slip stems had an all-cause revision rate of 1.8% (n = 11 of 599) versus composite beams (3.2%; n = 92 of 2,880; P = 0.07). There were no statistically significant differences observed in all-cause revision (hazard ratio [HR] 1.81; 95% confidence interval (CI) 0.96 to 3.40; P = 0.06), 90-day all-cause revision (HR 3.48; 95% CI, 0.82 to 14.67; P = 0.09), revision for fracture (HR, 0.90; 95% CI, 0.29 to 2.73; P = 0.86), aseptic loosening (HR, 1.77; 95% CI, 0.39 to 8.04; P = 0.46), infection (HR 1.40; 95% CI 0.41 to 4.79; P = 0.59), or dislocation (HR, 5.58; 95% CI, 0.76 to 41.0; P = 0.09) compared to composite beam stems after adjustment. CONCLUSIONS: There were no statistically significant differences in revision observed between taper-slip and composite beam-cemented femoral stems for patients undergoing THA for FNF. Clinically relevant trends (e.g., in early revision and dislocation) warrant further study with larger cohorts and longer follow-up.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipReoperationFemoral Neck FracturesHip ProsthesisProsthesis FailureProsthesis DesignHumansAgedFemaleMaleBone CementsPeriprosthetic FracturesAged, 80 and overRegistriesFollow-Up Studies

Stichwörter der Autor:innen

American Joint Replacement registrycemented femoral stemscemented total hip arthroplastyfemoral fixation in total hip arthroplastyfemoral stemtotal hip arthroplasty

Substanzen

Bone Cements

Autor:innen und Institutionen

  • Department of Orthopaedics, University of Missouri, Columbia, Missouri.
  • American Joint Replacement Registry Analytics Institute, Chicago, Illinois.
  • Department of Orthopaedics & Rehabilitation, Oregon Health & Science University, Portland, Oregon.
  • Department of Orthopaedics, Johns Hopkins University School of Medicine, Baltimore, Maryland.

Zitieren

APA

Gusho, C. A., Hoskins, W., Riley, C., Kelly, M., Hegde, V., Kagan, R., & Ghanem, E. S. (2026). Cemented Femoral Stem Design Is Not Associated With Differences in All-Cause Revision or Specific Failure Modes After Total Hip Arthroplasty for Femoral Neck Fracture. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2026.05.055

Vancouver

Gusho CA, Hoskins W, Riley C, Kelly M, Hegde V, Kagan R, et al. Cemented Femoral Stem Design Is Not Associated With Differences in All-Cause Revision or Specific Failure Modes After Total Hip Arthroplasty for Femoral Neck Fracture. The Journal of Arthroplasty. 2026. doi:10.1016/j.arth.2026.05.055

BibTeX
@article{Gusho2026,
  author = {Gusho, Charles A and Hoskins, Wayne and Riley, Connor and Kelly, Mackenzie and Hegde, Vishal and Kagan, Ryland and Ghanem, Elie S},
  title = {Cemented Femoral Stem Design Is Not Associated With Differences in All-Cause Revision or Specific Failure Modes After Total Hip Arthroplasty for Femoral Neck Fracture},
  journal = {The Journal of Arthroplasty},
  year = {2026},
  doi = {10.1016/j.arth.2026.05.055}
}
Kostenlos starten →