EUVIMEDEUVIMED entdecken
Crossref

Minimum Two-Year Survivorship of Large Femoral Heads With Titanium Sleeves in Primary Total Hip Arthroplasty: An Analysis From the American Joint Replacement Registry

Sanchez Marcel, Carender Chris, Zaniletti Isabella, James I Huddleston, Hegde Vishal

The Journal of Arthroplasty · 2026-09 · 41 (9) · S220-S227

DOI: 10.1016/j.arth.2026.04.052 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2026-09. Verfasst von Sanchez Marcel und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Stanford University School of Medicine, Stanford, California. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis, Prosthesis Failure, Titanium. Die Arbeit nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND Ceramic femoral heads with titanium sleeves (TSs) are used in revision total hip arthroplasty (THA) with femoral component retention to reduce the risk of femoral head fracture and trunnion corrosion. Their utility in primary THA, particularly for larger heads, is unknown. We sought to evaluate the influence of TSs on the risk of revision total hip arthroplasty based on ceramic head size. METHODS All primary THAs using ceramic heads (n = 213,749) reported to the American Joint Replacement Registry from January 2012 to December 2021 in patients at least 65 year old who had a minimum 2-year follow-up were analyzed. The THAs were categorized as using ≤ 28 mm (millimeter), 32 mm, 36 mm, or ≥ 40 mm femoral heads. There were 9% of the cases (n = 18,685) that utilized TS. Cause-specific Cox models were used to determine the risk of all-cause revision, accounting for age, sex, body mass index, and the Charlson Comorbidity Index. RESULTS Femoral head size influenced all-cause revision based on the presence of TS (P = 0.013). The 36 mm heads with TS had a higher all-cause revision rate than the 36 mm heads without TS (hazard ratio [HR] 1.34, 95% confidence interval [CI] 1.13 to 1.59, P < 0.001), driven by increased rates of revision for dislocation. Femoral heads ≥ 40 mm without TS had a higher all-cause revision rate than 36 mm heads without TS (HR 1.28, 95% CI 1.07 to 1.54, P < 0.008), driven by increased rates of revision for infection, dislocation, wear, and mechanical complications. There was no difference in all-cause revision between ≥ 40-mm heads with TS and 36 mm heads without TS (HR 1.00, 95% CI 0.70 to 1.44, P = 0.991). CONCLUSIONS Use of TS is associated with increased risk of revision with 36 mm ceramic heads. Compared to 36 mm heads, ≥ 40 mm heads without TS are associated with increased risk of revision, but there is no difference using ≥ 40 mm heads with TS. Risk of revision appears to be most influenced by head size. These findings should be considered when deciding on the use of TS in primary THA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipHip ProsthesisProsthesis FailureTitaniumFemur HeadHumansRegistriesFemaleAgedReoperationMaleProsthesis DesignUnited StatesAged, 80 and overFollow-Up Studies

Stichwörter der Autor:innen

corrosionfemoral headmicromotionprimary total hip arthroplastytitanium taper sleeve

Substanzen

Titanium

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Stanford University School of Medicine, Stanford, California.
  • Department of Orthopaedic Surgery, University of Michigan School of Medicine, Ann Arbor, Michigan.
  • Registries and Data Science Department, American Academy of Orthopaedic Surgeons, Rosemont, Illinois.
  • Department of Orthopaedic Surgery, Johns Hopkins University School of Medicine, Baltimore, Maryland.

Zitieren

APA

Marcel, S., Chris, C., Isabella, Z., Huddleston, J. I., & Vishal, H. (2026). Minimum Two-Year Survivorship of Large Femoral Heads With Titanium Sleeves in Primary Total Hip Arthroplasty: An Analysis From the American Joint Replacement Registry. The Journal of Arthroplasty, 41(9), S220-S227. https://doi.org/10.1016/j.arth.2026.04.052

Vancouver

Marcel S, Chris C, Isabella Z, Huddleston JI, Vishal H. Minimum Two-Year Survivorship of Large Femoral Heads With Titanium Sleeves in Primary Total Hip Arthroplasty: An Analysis From the American Joint Replacement Registry. The Journal of Arthroplasty. 2026;41(9):S220-S227. doi:10.1016/j.arth.2026.04.052

BibTeX
@article{Marcel2026,
  author = {Marcel, Sanchez and Chris, Carender and Isabella, Zaniletti and Huddleston, James I and Vishal, Hegde},
  title = {Minimum Two-Year Survivorship of Large Femoral Heads With Titanium Sleeves in Primary Total Hip Arthroplasty: An Analysis From the American Joint Replacement Registry},
  journal = {The Journal of Arthroplasty},
  year = {2026},
  volume = {41},
  number = {9},
  pages = {S220--S227},
  doi = {10.1016/j.arth.2026.04.052}
}
Kostenlos starten →