EUVIMEDEUVIMED entdecken
Crossref

Agreement of Patient Responses Between Electronic and Paper Patient-Reported Outcome Measures in Total Hip Arthroplasty

Asha Swamy, Meaghan Dufresne, Kaitlyn Chambers, Katie McIIquham, Peter Lapner, Paul E Beaule, George Grammatopoulos

The Journal of Arthroplasty · 2026-12 · 41 (12) · 3806-3811.e2

DOI: 10.1016/j.arth.2026.03.048 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2026-12. Verfasst von Asha Swamy und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Patient Reported Outcome Measures. Die Arbeit nennt 33 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Total hip arthroplasty (THA) outcomes are commonly assessed using patient-reported outcome measures (PROMs). As electronic PROMs (ePROMs) gain popularity, ensuring equivalence to paper PROMs (pPROMs) is essential. This study aimed to evaluate the interchangeability of ePROMs and pPROMs in patients undergoing THA. METHODS: A prospective cohort analysis of 96 THA patients who completed preoperative ePROMs and pPROMs was conducted. Electronic Oxford Hip Score (OHS) and EuroQol 5-Dimension 5-Level (EQ-5D-5L) were completed zero to 28 weeks prior to surgery, and pPROMs were completed on the day of surgery. Correlations were assessed with Spearman's rank correlation, and agreement and bias were evaluated using intraclass correlation coefficients (ICCs) and Bland-Altman analysis. The effect of time between completion of ePROM and pPROM on score difference was assessed. RESULTS: Electronic scores were lower than paper format (OHS: median 19.0 [interquartile range, 13.8 to 25.3] versus 19.0 [14.0 to 25.0]; difference -1.5; P = 0.005, EQ-5D-5L: median 0.575 [0.455 to 0.681] versus 0.597 [0.472 to 0.704]; difference -0.028; P = 0.05). Differences were below Minimal Clinically Important Differences. Agreement was good for OHS (ICC: 0.873, 95% confidence interval: 0.805 to 0.917) and moderate for EQ-5D-5L (ICC: 0.677, 95% confidence interval: 0.551 to 0.773). Minimal bias (OHS: -1.3, limits of agreement: -9.3 to 6.7; EQ-5D-5L: -0.025, limits of agreement: -0.26 to 0.20) was detected, with 14.6 and 2.1% of scores, respectively, exceeding Minimal Clinically Important Difference. The median time interval between ePROM and pPROM administration was six days (interquartile range, three to 27) and had no effect on differences. However, reduced variability was seen when ePROMs were completed within one week of surgery. CONCLUSIONS: Electronic and paper-based OHS and EQ-5D-5L show good agreement and can generally be used interchangeably. However, caution is required for individual scores near clinically important thresholds. Given their efficiency and scalability, we recommend a transition to ePROMs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipPatient Reported Outcome MeasuresHumansProspective StudiesFemaleAgedMiddle AgedMaleSurveys and QuestionnairesQuality of Life

Stichwörter der Autor:innen

EQ-5D-5LOxford Hip Scoreelectronic PROMspaper PROMspatient-reported outcome measurestotal hip arthroplasty

Autor:innen und Institutionen

  • Division of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada.

Zitieren

APA

Swamy, A., Dufresne, M., Chambers, K., McIIquham, K., Lapner, P., Beaule, P. E., & Grammatopoulos, G. (2026). Agreement of Patient Responses Between Electronic and Paper Patient-Reported Outcome Measures in Total Hip Arthroplasty. The Journal of Arthroplasty, 41(12), 3806-3811.e2. https://doi.org/10.1016/j.arth.2026.03.048

Vancouver

Swamy A, Dufresne M, Chambers K, McIIquham K, Lapner P, Beaule PE, et al. Agreement of Patient Responses Between Electronic and Paper Patient-Reported Outcome Measures in Total Hip Arthroplasty. The Journal of Arthroplasty. 2026;41(12):3806-3811.e2. doi:10.1016/j.arth.2026.03.048

BibTeX
@article{Swamy2026,
  author = {Swamy, Asha and Dufresne, Meaghan and Chambers, Kaitlyn and McIIquham, Katie and Lapner, Peter and Beaule, Paul E and Grammatopoulos, George},
  title = {Agreement of Patient Responses Between Electronic and Paper Patient-Reported Outcome Measures in Total Hip Arthroplasty},
  journal = {The Journal of Arthroplasty},
  year = {2026},
  volume = {41},
  number = {12},
  pages = {3806--3811.e2},
  doi = {10.1016/j.arth.2026.03.048}
}
Kostenlos starten →