EUVIMEDEUVIMED entdecken
Crossref

Failure Incidence and Predictors Following Manipulation Under Anesthesia for the Stiff Total Knee Arthroplasty

Matthew T Hurn, Josue R Balbuena, Emma E Heironimus, Joseph D Henningsen, Langan S Smith, Edward D Tillett, Arthur L Malkani

The Journal of Arthroplasty · 2026-12 · 41 (12) · 3864-3869

DOI: 10.1016/j.arth.2026.03.045 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2026-12. Verfasst von Matthew T Hurn und 6 weiteren Autor:innen. Beteiligte Einrichtung: University of Louisville, Department of Orthopaedic Surgery, Louisville, Kentucky. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Joint, Manipulation, Orthopedic, Anesthesia. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 42 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Manipulation under anesthesia (MUA) is a common treatment for stiffness following total knee arthroplasty (TKA). The purpose of this study was to evaluate the outcomes following MUA and identify risk factors for additional surgical intervention. METHODS: This study analyzed 227 knees that underwent MUA following primary TKA with 1-year follow-up. The 39 patients (17.2%) who required additional intervention were compared to 174 patients who underwent MUA without further interventions. There were no differences in body mass index, American Society of Anesthesiologists class, and prior knee surgeries. The mean follow-up was 38.5 months (range, 12 to 119.5) in the failure group and 39.2 (range, 12 to 124.2) in the control cohort. RESULTS: Of the 39 patients requiring additional procedures, 29 (74%) underwent arthroscopic lysis of adhesions and 15 (38%) revision TKA. Range of motion (ROM) two weeks following MUA was lower in patients who had additional interventions (96.4 versus 107.4°, P < 0.001), as was ROM at one year (103.1 versus 112.9°, P < 0.001). Multivariate analyses found age, cruciate-retaining implants, and ROM two weeks after MUA as independently associated with failure. There were no differences in preoperative Knee Society Score (KSS) Function, KSS Knee, and Knee Injury and Osteoarthritis Outcome Score for Joint Replacement scores. At the latest follow-up, patients who failed MUA had inferior KSS Knee (79.1 versus 89.0, P = 0.003), Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (65.0 versus 80.2, P < 0.01), Forgotten Joint Score-12 (39.1 versus 62.0, P < 0.01), and Likert satisfaction scores (3.5 versus 4.5, P < 0.01). CONCLUSIONS: This study demonstrated a 17.2% reoperation incidence following MUA. Decreased ROM at two weeks, age, and cruciate-retaining implants were associated with additional intervention. These findings underscore the importance of early ROM recovery following MUA and the need for better understanding the biologic aspects of arthrofibrosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeKnee JointManipulation, OrthopedicAnesthesiaHumansRange of Motion, ArticularFemaleAgedMaleMiddle AgedReoperationIncidenceRisk FactorsFollow-Up StudiesRetrospective StudiesAged, 80 and overTreatment FailureOsteoarthritis, Knee

Stichwörter der Autor:innen

arthrofibrosismanipulation under anesthesiarange of motionstiffnesstotal knee arthroplasty

Autor:innen und Institutionen

  • University of Louisville, Department of Orthopaedic Surgery, Louisville, Kentucky.
  • University of Louisville School of Medicine, Louisville, Kentucky.
  • UofL Health, ULP Orthopedics, Louisville, Kentucky.
  • Adult Reconstruction Program, Department of Orthopaedic Surgery, University of Louisville, Louisville, Kentucky.

Zitieren

APA

Hurn, M. T., Balbuena, J. R., Heironimus, E. E., Henningsen, J. D., Smith, L. S., Tillett, E. D., & Malkani, A. L. (2026). Failure Incidence and Predictors Following Manipulation Under Anesthesia for the Stiff Total Knee Arthroplasty. The Journal of Arthroplasty, 41(12), 3864-3869. https://doi.org/10.1016/j.arth.2026.03.045

Vancouver

Hurn MT, Balbuena JR, Heironimus EE, Henningsen JD, Smith LS, Tillett ED, et al. Failure Incidence and Predictors Following Manipulation Under Anesthesia for the Stiff Total Knee Arthroplasty. The Journal of Arthroplasty. 2026;41(12):3864-3869. doi:10.1016/j.arth.2026.03.045

BibTeX
@article{Hurn2026,
  author = {Hurn, Matthew T and Balbuena, Josue R and Heironimus, Emma E and Henningsen, Joseph D and Smith, Langan S and Tillett, Edward D and Malkani, Arthur L},
  title = {Failure Incidence and Predictors Following Manipulation Under Anesthesia for the Stiff Total Knee Arthroplasty},
  journal = {The Journal of Arthroplasty},
  year = {2026},
  volume = {41},
  number = {12},
  pages = {3864--3869},
  doi = {10.1016/j.arth.2026.03.045}
}
Kostenlos starten →