Dislocation Risk in Modern Total Hip Arthroplasty: Comparing Surgical Approaches With and Without Enabling Technology
The Journal of Arthroplasty · 2026-09 · 41 (9) · S185-S191
DOI: 10.1016/j.arth.2026.03.036 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Arthroplasty, 2026-09. Verfasst von Aymen Alqazzaz und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Columbia University Vagelos College of Physicians and Surgeons, New York, New York. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Periprosthetic Fractures, Hip Dislocation, Postoperative Complications. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 18 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND Dislocation remains a common complication following total hip arthroplasty (THA). Although surgical approach and enabling technologies may influence dislocation risk, their combined impact remains unclear. This study compared dislocation, periprosthetic fracture, and revision rates across four THA cohorts defined by surgical approach and technology use. METHODS We performed a retrospective cohort study of 3,243 consecutive primary THAs performed by seven fellowship-trained surgeons between May 2013 and December 2023. Patients were categorized into four cohorts: posterior approach (PA)-conventional (n = 1,817); direct anterior approach-conventional fluoroscopy (n = 979); direct anterior approach-navigation (n = 336); and PA-robotic (n = 111). The mean follow-up was 1.4 years (range, 90 days to three years). Multivariable logistic regressions were used to adjust for baseline differences. RESULTS Overall complication rates were low: dislocation 1.0% (33 of 3,243), periprosthetic fracture 2.2% (70 of 3,243), and revision 3.2% (104 of 3,243). Dislocation rates by cohort were PA-conventional 1.2%, direct anterior approach-conventional fluoroscopy 0.7%, direct anterior approach-navigation 0.3%, and PA-robotic 2.7% (P = 0.09). Neither unadjusted nor adjusted multivariable analyses demonstrated significant differences between cohorts for any outcome. Active tobacco use was significantly associated with increased dislocation risk (odds ratio 6.31, P < 0.001). CONCLUSIONS Multiple surgical approaches and technology platforms achieved excellent early outcomes with low complication rates in experienced hands. Although numeric trends favored direct anterior navigation (0.3% dislocation), differences were not statistically significant. Adequately powered prospective studies are needed to determine the incremental clinical benefit of enabling technologies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Columbia University Vagelos College of Physicians and Surgeons, New York, New York.
- Department of Orthopaedic Surgery, University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania.
Zitieren
APA
Alqazzaz, A., Chen, A. T., Smith, W. E., Travers, C., Gibon, E., & Nelson, C. L. (2026). Dislocation Risk in Modern Total Hip Arthroplasty: Comparing Surgical Approaches With and Without Enabling Technology. The Journal of Arthroplasty, 41(9), S185-S191. https://doi.org/10.1016/j.arth.2026.03.036
Vancouver
Alqazzaz A, Chen AT, Smith WE, Travers C, Gibon E, Nelson CL. Dislocation Risk in Modern Total Hip Arthroplasty: Comparing Surgical Approaches With and Without Enabling Technology. The Journal of Arthroplasty. 2026;41(9):S185-S191. doi:10.1016/j.arth.2026.03.036
BibTeX
@article{Alqazzaz2026,
author = {Alqazzaz, Aymen and Chen, Angela T and Smith, Weston E and Travers, Christopher and Gibon, Emannuel and Nelson, Charles L},
title = {Dislocation Risk in Modern Total Hip Arthroplasty: Comparing Surgical Approaches With and Without Enabling Technology},
journal = {The Journal of Arthroplasty},
year = {2026},
volume = {41},
number = {9},
pages = {S185--S191},
doi = {10.1016/j.arth.2026.03.036}
}