EUVIMEDEUVIMED entdecken
Crossref

Synovial Absolute Neutrophil Count as a Superior Diagnostic Biomarker for Acute Periprosthetic Joint Infection in Hip and Knee Arthroplasty With Low-Virulence Organisms

Taner Karlidag, Ashwin Mundhe, Luigi Zanna, Thorsten Gehrke, Mustafa Citak

The Journal of Arthroplasty · 2025

DOI: 10.1016/j.arth.2025.11.033 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2025. Verfasst von Taner Karlidag und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany; Department of Orthopaedics and Traumatology, Gaziantep City Hospital…. Hauptthemen laut MEDLINE: Prosthesis-Related Infections, Arthroplasty, Replacement, Hip, Arthroplasty, Replacement, Knee, Synovial Fluid. Die Arbeit nennt 33 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Diagnosing acute periprosthetic joint infection (PJI) soon after surgery presents a challenge because the inflammation caused by the procedure can mimic that of an infection. Key diagnostic measures include synovial white blood cell (WBC) count, polymorphonuclear percentage (PMN%), and alpha-defensin (AD). Nevertheless, the precise thresholds, particularly for infections with low virulence, remain ambiguous. This research assessed the effectiveness of synovial absolute neutrophil count (ANC) in diagnosing acute PJI in hip and knee joints and established specific thresholds based on the procedure and the organism involved. METHODS: An examination was carried out on 502 patients who underwent joint aspiration within a 90-day period following their primary total joint arthroplasty, conducted from March 2011 to August 2022 at a tertiary arthroplasty center. Of the 502 patients, 123 (24.5%) had an acute PJI. The diagnosis of PJI was established according to the criteria set by the 2018 International Consensus Meeting. Receiver operating characteristic curves were used to assess synovial fluid WBC, PMN%, ANC, and AD, aiming to determine the optimal cutoff values for total knee arthroplasty and total hip arthroplasty, with differentiation according to the virulence of the organism. RESULTS: For total knee arthroplasty, optimal thresholds were WBC 5,162 cells/μL, PMN% 88.5%, AD 1.7, and ANC 2,881 cells/μL (area under the curve 0.98; sensitivity 96.8%, specificity 95.5%). For total hip arthroplasty, thresholds were WBC 6,273 cells/μL, PMN% 87.2%, AD 1.4, and ANC 3,860 cells/μL (area under the curve 0.98; sensitivity 95.4%, specificity 94.1%). Organism-specific analysis showed lower synovial values in culture-negative and coagulase-negative Staphylococcus infections and higher values in Staphylococcus aureus and antibiotic-resistant strains. The ANC demonstrated improved diagnostic sensitivity for detecting low-virulence infections compared with other markers. CONCLUSIONS: Synovial ANC is a cost-effective, accessible, and highly accurate diagnostic tool for acute PJI in both hip and knee arthroplasty. It showed improved diagnostic performance in low-virulence infections, and the procedure-specific thresholds identified in this study support its integration into early diagnostic protocols to improve detection, enable timely intervention, and reduce reliance on costly assays such as AD. LEVEL OF EVIDENCE: Level III.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prosthesis-Related InfectionsArthroplasty, Replacement, HipArthroplasty, Replacement, KneeSynovial FluidNeutrophilsHumansFemaleBiomarkersMaleLeukocyte CountAgedMiddle AgedVirulencealpha-DefensinsAged, 80 and over

Stichwörter der Autor:innen

absolute neutrophil countacute periprosthetic joint infectiondiagnosinglow-virulent organismssynovial biomarkers

Substanzen

Biomarkersalpha-Defensins

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany; Department of Orthopaedics and Traumatology, Gaziantep City Hospital, Gaziantep, Turkey.
  • Department of Orthopaedic Surgery, Sana- Klinikum Remscheid GmbH, Hamburg, Germany.
  • Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany.

Zitieren

APA

Karlidag, T., Mundhe, A., Zanna, L., Gehrke, T., & Citak, M. (2025). Synovial Absolute Neutrophil Count as a Superior Diagnostic Biomarker for Acute Periprosthetic Joint Infection in Hip and Knee Arthroplasty With Low-Virulence Organisms. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2025.11.033

Vancouver

Karlidag T, Mundhe A, Zanna L, Gehrke T, Citak M. Synovial Absolute Neutrophil Count as a Superior Diagnostic Biomarker for Acute Periprosthetic Joint Infection in Hip and Knee Arthroplasty With Low-Virulence Organisms. The Journal of Arthroplasty. 2025. doi:10.1016/j.arth.2025.11.033

BibTeX
@article{Karlidag2025,
  author = {Karlidag, Taner and Mundhe, Ashwin and Zanna, Luigi and Gehrke, Thorsten and Citak, Mustafa},
  title = {Synovial Absolute Neutrophil Count as a Superior Diagnostic Biomarker for Acute Periprosthetic Joint Infection in Hip and Knee Arthroplasty With Low-Virulence Organisms},
  journal = {The Journal of Arthroplasty},
  year = {2025},
  doi = {10.1016/j.arth.2025.11.033}
}
Kostenlos starten →