Triple-Taper Collared Stem Morphology Influences Periprosthetic Femoral Fracture Risk: A Comparison of Single-, Dual-, Triple-, and Quadrangular-Taper Stems
The Journal of Arthroplasty · 2026-07 · 41 (7) · 2101-2105
DOI: 10.1016/j.arth.2025.10.045 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Arthroplasty, 2026-07. Verfasst von Drake G LeBrun und 3 weiteren Autor:innen. Beteiligte Einrichtung: Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, New York. Hauptthemen laut MEDLINE: Periprosthetic Fractures, Arthroplasty, Replacement, Hip, Hip Prosthesis, Femoral Fractures. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 19 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Stem morphology is an important contributor to periprosthetic femoral fracture (PFF) risk following total hip arthroplasty (THA). New-generation triple-taper collared stems may be associated with a lower risk of PFF. Our objective was to compare the incidence of PFFs in triple-taper collared stems to three other cementless stem morphologies. METHODS: A single-institution retrospective cohort study was performed. All primary THA cases (n = 23,448) from February 2016 to December 2023 using cementless single-taper (n = 8,529), dual-taper (n = 8,514), triple-taper collared (n = 4,024), and quadrangular-taper stems (n = 2,381) from four major implant companies were evaluated. Outcomes were any PFF, intraoperative PFF, and early (90 days) postoperative PFF. RESULTS: Any PFF occurred in 60 of 8,529 (0.70%) single-taper, 114 of 8,514 (1.34%) dual-taper, 15 of 4,024 (0.37%) triple-taper collared, and 26 of 2,381 (1.09%) quadrangular-taper stems (overall difference, P < 0.01). Intraoperative fractures occurred in 30 single-taper (0.35%), 69 dual-taper (0.81%), 10 triple-taper collared (0.25%), and 22 (0.92%) quadrangular-taper stems (P < 0.01). Postoperative fractures occurred in 30 single-taper (0.35%), 47 dual-taper (0.55%), five triple-taper collared (0.12%), and four (0.17%) quadrangular-taper stems (P < 0.01). Collared stems (including quadrangular-taper collared stems) had a lower postoperative fracture rate compared to noncollared stems (0.15 versus 0.44%, P < 0.01). After accounting for age, sex, body mass index, American Society of Anesthesiologists' score, tobacco use, and surgical approach, triple-taper collared stems had a lower risk of intraoperative fracture compared to dual-taper (odds ratio (OR) 0.3, P < 0.01) and quadrangular-taper stems (OR 0.3, P < 0.01). The triple-taper collared stems also had a lower rate of postoperative fracture compared to dual-taper stems (OR 0.3, P < 0.01). CONCLUSIONS: In a cohort of over 23,000 patients undergoing cementless THA, triple-taper collared femoral stems had the lowest rates of intra-operative and postoperative PFF compared to other cementless stem morphologies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, New York.
Zitieren
APA
LeBrun, D. G., Ruiz, V., Gausden, E. B., & Westrich, G. H. (2026). Triple-Taper Collared Stem Morphology Influences Periprosthetic Femoral Fracture Risk: A Comparison of Single-, Dual-, Triple-, and Quadrangular-Taper Stems. The Journal of Arthroplasty, 41(7), 2101-2105. https://doi.org/10.1016/j.arth.2025.10.045
Vancouver
LeBrun DG, Ruiz V, Gausden EB, Westrich GH. Triple-Taper Collared Stem Morphology Influences Periprosthetic Femoral Fracture Risk: A Comparison of Single-, Dual-, Triple-, and Quadrangular-Taper Stems. The Journal of Arthroplasty. 2026;41(7):2101-2105. doi:10.1016/j.arth.2025.10.045
BibTeX
@article{LeBrun2026,
author = {LeBrun, Drake G and Ruiz, Vanessa and Gausden, Elizabeth B and Westrich, Geoffrey H},
title = {Triple-Taper Collared Stem Morphology Influences Periprosthetic Femoral Fracture Risk: A Comparison of Single-, Dual-, Triple-, and Quadrangular-Taper Stems},
journal = {The Journal of Arthroplasty},
year = {2026},
volume = {41},
number = {7},
pages = {2101--2105},
doi = {10.1016/j.arth.2025.10.045}
}
EUVIMED