EUVIMEDEUVIMED entdecken
Crossref

Minimum 10-Year Follow-Up of Patients 50 Years or less Undergoing Total Hip Arthroplasty Who Have Fourth-Generation Ceramic 32-mm Femoral Heads on Highly Cross-Linked Polyethylene

Syed A Adil, Joseph T Gutbrod, Vivek P Shah, Gail E Pashos, Ilya Bendich, John C Clohisy

The Journal of Arthroplasty · 2025

DOI: 10.1016/j.arth.2025.08.077 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2025. Verfasst von Syed A Adil und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Washington University School of Medicine, Washington University in St Louis, St. Louis, Missouri. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis, Prosthesis Design, Polyethylene. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: Foundation for Barnes-Jewish Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Total hip arthroplasty (THA) with third-generation alumina ceramic heads on highly cross-linked polyethylene liners (HXLPE) has demonstrated excellent outcomes in young patients. However, there is limited data for fourth-generation ceramic heads. The purpose of our study was to report on clinical and wear, outcomes of THA with fourth-generation 32-mm ceramic femoral heads and HXLPE liners in patients 50 years or younger at 10-year minimum follow-up. METHODS: This was a retrospective study of 103 THAs with fourth-generation 32-mm ceramic femoral heads on HXLPE between December 2008 and December 2010. The mean age was 37 years (range, 13 to 50). The modified Harris Hip Score, University of California, Los Angeles Activity Score, and Western Ontario and McMaster University Osteoarthritis Index pain score were collected preoperatively and at each follow-up. Martell Hip Analysis was used for wear calculations. RESULTS: Survivorship from all-cause revision was 97.1% (95% confidence interval (CI), 93.8 to 100.0) at 5 years, 97.1% (95% CI, 93.8 to 100.0) at 10 years, and 95.4% (95% CI, 90.9 to 99.9) at 15 years. Survivorship from wear-related revision was 100% at 15 years. There were four hips (3.9%) that underwent revision at a mean of 5.1 years (range, 0.04 to 13.2) postoperatively. The mean linear wear rate was 0.0184 mm/year (SD ± 0.043); the mean volumetric wear rate was 18.38 mm3/year (SD ± 22.55). Improvements were observed in the modified Harris Hip Score (48 ± 16 to 84 ± 22; P < 0.001), University of California, Los Angeles score (5.5 ± 2.3 to 6.2 ± 2.1; P = 0.031), and Western Ontario and McMaster Universities Arthritis Index pain score (45 ± 21 to 86 ± 23; P < 0.001). Patient satisfaction scores were 73% "extremely satisfied" and 13% "very satisfied." CONCLUSIONS: The fourth-generation ceramic 32-mm femoral heads on HXLPE in THA for patients aged 50 years or younger demonstrate excellent survivorship, minimal wear, and high patient satisfaction at a 10-year minimum follow-up.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipHip ProsthesisProsthesis DesignPolyethyleneHumansRetrospective StudiesMiddle AgedFollow-Up StudiesFemaleMaleAdultCeramicsAdolescentYoung AdultProsthesis FailureReoperationTreatment OutcomeFemur Head

Stichwörter der Autor:innen

alumina ceramicceramichighly crosslinked polyethyleneprimary total hip arthroplastywearyoung patient

Substanzen

Polyethylene

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Washington University School of Medicine, Washington University in St Louis, St. Louis, Missouri.

Förderung

  • Foundation for Barnes-Jewish Hospital

Zitieren

APA

Adil, S. A., Gutbrod, J. T., Shah, V. P., Pashos, G. E., Bendich, I., & Clohisy, J. C. (2025). Minimum 10-Year Follow-Up of Patients 50 Years or less Undergoing Total Hip Arthroplasty Who Have Fourth-Generation Ceramic 32-mm Femoral Heads on Highly Cross-Linked Polyethylene. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2025.08.077

Vancouver

Adil SA, Gutbrod JT, Shah VP, Pashos GE, Bendich I, Clohisy JC. Minimum 10-Year Follow-Up of Patients 50 Years or less Undergoing Total Hip Arthroplasty Who Have Fourth-Generation Ceramic 32-mm Femoral Heads on Highly Cross-Linked Polyethylene. The Journal of Arthroplasty. 2025. doi:10.1016/j.arth.2025.08.077

BibTeX
@article{Adil2025,
  author = {Adil, Syed A and Gutbrod, Joseph T and Shah, Vivek P and Pashos, Gail E and Bendich, Ilya and Clohisy, John C},
  title = {Minimum 10-Year Follow-Up of Patients 50 Years or less Undergoing Total Hip Arthroplasty Who Have Fourth-Generation Ceramic 32-mm Femoral Heads on Highly Cross-Linked Polyethylene},
  journal = {The Journal of Arthroplasty},
  year = {2025},
  doi = {10.1016/j.arth.2025.08.077}
}
Kostenlos starten →