EUVIMEDEUVIMED entdecken
Crossref

Aseptic Tibial Loosening Is Associated With Thickness of the Cement: A Radiographic Case–Control Study

Benjamin C Schaffler, Joseph X Robin, Jonathan Katzman, Armin Arshi, Joshua C Rozell, Ran Schwarzkopf

The Journal of Arthroplasty · 2025

DOI: 10.1016/j.arth.2024.12.023 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2025. Verfasst von Benjamin C Schaffler und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, NYU Langone Health, New York, New York. Hauptthemen laut MEDLINE: Bone Cements, Prosthesis Failure, Arthroplasty, Replacement, Knee, Knee Prosthesis. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 38 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The cementation technique is crucial for achieving adequate fixation and optimal survivorship in total knee arthroplasty (TKA). The thickness of the cement at the tibial bone-implant surface may be related to aseptic tibial loosening. However, to date, no studies have demonstrated a direct association between cement thickness and rates of aseptic tibial loosening. METHODS: We performed a retrospective review to identify 28,327 primary cemented TKAs with at least 2 years of follow-up at an academic health system from 2013 to 2021. A total of 115 cases underwent revision surgery for aseptic tibial loosening. Cases where the implant was recalled specifically for loosening (n = 23) were excluded. The remaining 92 aseptic tibial loosening cases were 2:1 propensity score matched and implant matched to control patients who did not have tibial loosening. There were two independent reviewers who then measured the thickness of the cement interface in 10 locations along the bone-implant interface from initial postoperative radiographs. The averages of the reviewers' measurements were calculated and then compared using independent t-tests. RESULTS: Aseptic tibial loosening cases involving implant A tibial baseplate (n = 75) had significantly thinner cement interfaces than matched controls at all the 10 locations measured. Aseptic loosening cases involving implant B (n = 17) also displayed a thinner cement interface than matched controls in all locations, but this result was only statistically significant at the medial baseplate, medial keel, lateral keel, anterior keel, and posterior baseplate. CONCLUSIONS: In two widely used TKA systems, tibial aseptic loosening was associated with significantly thinner cement interfaces when compared to propensity-matched controls in two different implant types. Further prospective studies are needed to identify the optimal keel preparation and design as well as minimal cement interface thickness to avoid implant loosening. LEVEL OF EVIDENCE: III.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bone CementsProsthesis FailureArthroplasty, Replacement, KneeKnee ProsthesisTibiaCementationHumansRetrospective StudiesMaleFemaleAgedCase-Control StudiesMiddle AgedReoperationRadiographyAged, 80 and over

Stichwörter der Autor:innen

aseptic looseningcement interfacecement techniquecomplicationstotal knee arthroplasty

Substanzen

Bone Cements

Autor:innen und Institutionen

  • Department of Orthopedic Surgery, NYU Langone Health, New York, New York.

Zitieren

APA

Schaffler, B. C., Robin, J. X., Katzman, J., Arshi, A., Rozell, J. C., & Schwarzkopf, R. (2025). Aseptic Tibial Loosening Is Associated With Thickness of the Cement: A Radiographic Case–Control Study. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2024.12.023

Vancouver

Schaffler BC, Robin JX, Katzman J, Arshi A, Rozell JC, Schwarzkopf R. Aseptic Tibial Loosening Is Associated With Thickness of the Cement: A Radiographic Case–Control Study. The Journal of Arthroplasty. 2025. doi:10.1016/j.arth.2024.12.023

BibTeX
@article{Schaffler2025,
  author = {Schaffler, Benjamin C and Robin, Joseph X and Katzman, Jonathan and Arshi, Armin and Rozell, Joshua C and Schwarzkopf, Ran},
  title = {Aseptic Tibial Loosening Is Associated With Thickness of the Cement: A Radiographic Case–Control Study},
  journal = {The Journal of Arthroplasty},
  year = {2025},
  doi = {10.1016/j.arth.2024.12.023}
}
Kostenlos starten →