EUVIMEDEUVIMED entdecken
Multizentrische Studie

Clinical and Radiographic Outcomes of a Long Cementless Monobloc Stem for Revision Total Hip Arthroplasty Due to Chronic Periprosthetic Infection

Xing Liu, Yuhang Gao, Yi Leng, Jiarui Zhou, Xin Qi

The Journal of Arthroplasty · 2025

DOI: 10.1016/j.arth.2024.11.007 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift The Journal of Arthroplasty, 2025. Verfasst von Xing Liu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Orthopaedic Center, The First Hospital of Jilin University, Changchun, Jilin, China. Hauptthemen laut MEDLINE: Prosthesis-Related Infections, Reoperation, Arthroplasty, Replacement, Hip, Hip Prosthesis. Die Arbeit nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: A long cementless monobloc stem is widely used for aseptic loosening, with satisfactory 5- to-10-year outcomes reported. Nonetheless, related studies on chronic periprosthetic joint infection (PJI) are scant. This study evaluated the clinical and radiographic outcomes of the stem in 2-stage revisions due to PJI. METHODS: This prospective multicenter cohort study consisted of patients from three medical centers who were enrolled in a single arm from January 2017 to May 2022. All patients were diagnosed with chronic PJI based on the International Consensus Meeting criteria and underwent 2-stage revisions using a long monobloc cementless revision stem. Among 44 patients, 37 (12 women and 25 men) completed an average follow-up of 35.6 months (range, 14 to 75). The primary outcome was the stability of the stem; secondary outcomes included infection eradication, Harris Hip Score, leg length discrepancy, major complications, and isolated pathogens at intraoperative cultures. RESULTS: At 1 year after revision, the infection-free prosthesis survival rate was 97.3% (95% confidence interval: 96.4 to 98.2). At the last follow-up, the mean subsidence was 2.9 ± 2.1 mm (range, 0.8 to 4.8). Postoperative leg length discrepancy averaged -4.6 ± 4.9 mm (range, -16 to 0). The Engh score averaged 14.1 ± 6.9 (range, zero to 22). The Harris Hip Score improved from a preoperative average of 35.7 ± 8.5 (range, 12 to 50) to 80.4 ± 9.3 (range, 58 to 92) at the 1-year postoperative follow-up (P < 0.01). CONCLUSIONS: The long cementless monobloc stem used in the current study presents a feasible option for 2-stage revision in cases of chronic PJI. The bone ingrowth and stability could be observed within the short follow-up time. LEVEL OF EVIDENCE: Level IV, prospective cohort study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prosthesis-Related InfectionsReoperationArthroplasty, Replacement, HipHip ProsthesisHumansFemaleMaleAgedMiddle AgedProspective StudiesProsthesis DesignChronic DiseaseTreatment OutcomeAged, 80 and overAdultFollow-Up StudiesHip Joint

Stichwörter der Autor:innen

chronic periprosthetic infectionclinical outcomesmonobloc stemradiographic outcomesrevision total hip arthroplasty

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Orthopaedic Center, The First Hospital of Jilin University, Changchun, Jilin, China.

Zitieren

APA

Liu, X., Gao, Y., Leng, Y., Zhou, J., & Qi, X. (2025). Clinical and Radiographic Outcomes of a Long Cementless Monobloc Stem for Revision Total Hip Arthroplasty Due to Chronic Periprosthetic Infection. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2024.11.007

Vancouver

Liu X, Gao Y, Leng Y, Zhou J, Qi X. Clinical and Radiographic Outcomes of a Long Cementless Monobloc Stem for Revision Total Hip Arthroplasty Due to Chronic Periprosthetic Infection. The Journal of Arthroplasty. 2025. doi:10.1016/j.arth.2024.11.007

BibTeX
@article{Liu2025,
  author = {Liu, Xing and Gao, Yuhang and Leng, Yi and Zhou, Jiarui and Qi, Xin},
  title = {Clinical and Radiographic Outcomes of a Long Cementless Monobloc Stem for Revision Total Hip Arthroplasty Due to Chronic Periprosthetic Infection},
  journal = {The Journal of Arthroplasty},
  year = {2025},
  doi = {10.1016/j.arth.2024.11.007}
}
Kostenlos starten →