Adductor Catheter Insertion Through the Knee Arthrotomy: Can This Technique Be as Safe and Effective as Ultrasound-Guided Insertion?
The Journal of Arthroplasty · 2025
DOI: 10.1016/j.arth.2024.09.003 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift The Journal of Arthroplasty, 2025. Verfasst von Manan N Shah und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Sir H.N Reliance Foundation Hospital, Mumbai, Maharashtra, India. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Ultrasonography, Interventional, Postoperative Pain, Knee Joint. Die Arbeit nennt 23 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Early postoperative pain following total knee arthroplasty remains challenging. We devised a technique for inserting a continuous catheter intraoperatively in the adductor canal and aimed to compare its efficacy and safety with that of an ultrasound-guided anesthetist-administered continuous catheter. METHODS: This single-center, single-surgeon, prospective, interventional, randomized controlled trial included 330 patients, who were randomized into two groups with similar preoperative status and demographics. There were 18 patients who met the exclusion criteria. Group A (n = 152) received the block from an anesthetist, while group B (n = 160) received the block from the surgeon. Patients had visual analog scale scores, range of motion, maximum ambulation distance, time to straight leg raise, length of stay, and results from a 10-meter walk test, Timed Up and Go test, and a 30-second chair test measured preoperatively and at 6, 12, and 24 hours postoperatively by a physiotherapist and pain nurse blinded to the group assignment. RESULTS: The visual analog scale scores at 12 hours postsurgery were significantly lower in group B (0.66) compared to group A (0.77, P = 0.04). Range of motion (supine flexion 43.2 versus 43.1, P = 0.72; sitting flexion 90.0 versus 89.9, P = 0.17), Timed Up and Go test (126.1 versus 136.9, P = 0.9), 10-meter walk test (163.5 versus 165.4, P = 0.7), 30-second chair test (3.7 versus 3.8, P = 0.7), time to active straight leg raise (4.0 versus 4.1, P = 0.3), time to ambulation with walker (4.02 versus 4.05, P = 0.3), and length of stay (1.44 versus 1.39, P = 0.49) showed no significant differences between the groups. No serious complications were reported in either group. CONCLUSIONS: We concluded that this technique was at least as safe and effective as the USG-guided, anesthetist-administered adductor canal catheter.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics, Sir H.N Reliance Foundation Hospital, Mumbai, Maharashtra, India.
- Department of Anaesthesia, Sir H.N Reliance Foundation Hospital, Mumbai, Maharashtra, India.
- Department of Physiotherapy, Sir H.N Reliance Foundation Hospital, Mumbai, Maharashtra, India.
Zitieren
APA
Shah, M. N., Desai, S. D., Thakkar, P. N., Jain, A. V., & Shah, N. A. (2025). Adductor Catheter Insertion Through the Knee Arthrotomy: Can This Technique Be as Safe and Effective as Ultrasound-Guided Insertion?. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2024.09.003
Vancouver
Shah MN, Desai SD, Thakkar PN, Jain AV, Shah NA. Adductor Catheter Insertion Through the Knee Arthrotomy: Can This Technique Be as Safe and Effective as Ultrasound-Guided Insertion?. The Journal of Arthroplasty. 2025. doi:10.1016/j.arth.2024.09.003
BibTeX
@article{Shah2025,
author = {Shah, Manan N and Desai, Sameer D and Thakkar, Parna N and Jain, Aanchal V and Shah, Nilen A},
title = {Adductor Catheter Insertion Through the Knee Arthrotomy: Can This Technique Be as Safe and Effective as Ultrasound-Guided Insertion?},
journal = {The Journal of Arthroplasty},
year = {2025},
doi = {10.1016/j.arth.2024.09.003}
}
EUVIMED