Primarily Constraining Custom Triflange Patients: Weighing the Risks of Instability Versus Fixation?
The Journal of Arthroplasty · 2025
DOI: 10.1016/j.arth.2024.08.040 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Arthroplasty, 2025. Verfasst von Aleksander P Mika und 7 weiteren Autor:innen. Beteiligte Einrichtung: Vanderbilt University Medical Center, Nashville, Tennessee. Hauptthemen laut MEDLINE: Hip Prosthesis, Arthroplasty, Replacement, Hip, Acetabulum, Joint Instability. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NCATS NIH HHS, National Center for Advancing Translational Sciences.
Abstract (Originalsprache)
BACKGROUND: Custom triflange acetabular components (CTACs) can be used to manage patients with severe acetabular bone loss. However, instability remains one of the primary reasons for reoperation and revision for these patients. Primarily constraining these patients is an attractive option to minimize the risk of instability, but theoretically puts more stress on the implant fixation and leads to subsequent failure. Therefore, this study aimed to compare outcomes between patients managed with CTACs with standard liners (SLs) versus those with constrained liners (CLs) at the index procedure. METHODS: We identified patients treated with a CTAC for severe acetabular bone loss with a minimum two-year follow-up. Patients received either a CL or SL. Patient demographics and intraoperative details were described, and comparative survival analyses were conducted on all time-to-complication outcomes: years to triflange component failure (aseptic revision and all indications), other revisions of the component exclusive of CTAC, reoperation where no components were exchanged, and dislocation. RESULTS: There were 37 patients treated with CTAC who received SLs and 44 who received CLs, for a total cohort of 81. The median follow-up time was 4.2 years (interquartile range, 2.6 to 6.7; min/max range, two to 15). Analysis showed no significant survival estimate differences in years to triflange component failure (aseptic revision, P = 0.800, and all indications, P = 0.800), other revisions of the construct exclusive of CTAC (P = 0.500), reoperation where no components were exchanged (P = 0.400), and dislocation (P = 0.500). DISCUSSION AND CONCLUSION: Our findings suggest the use of acute CL appears to represent a safe and appropriate option in patients with substantial instability risks without increased risk of component failure compared to SLs over time. Therefore, we recommend consideration of CL in high-risk instability patients requiring CTAC.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Vanderbilt University Medical Center, Nashville, Tennessee.
- Southern Joint Replacement Institute, Nashville, Tennessee.
Förderung
- NCATS NIH HHS
- National Center for Advancing Translational Sciences
Zitieren
APA
Mika, A. P., Wilson, J. M., Christie, M. J., Christie, M. C., DeBoer, D. K., Morrison, J. C., Polkowski, G. G., & Martin, J. R. (2025). Primarily Constraining Custom Triflange Patients: Weighing the Risks of Instability Versus Fixation?. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2024.08.040
Vancouver
Mika AP, Wilson JM, Christie MJ, Christie MC, DeBoer DK, Morrison JC, et al. Primarily Constraining Custom Triflange Patients: Weighing the Risks of Instability Versus Fixation?. The Journal of Arthroplasty. 2025. doi:10.1016/j.arth.2024.08.040
BibTeX
@article{Mika2025,
author = {Mika, Aleksander P and Wilson, Jacob M and Christie, Michael J and Christie, Matthew C and DeBoer, David K and Morrison, J Craig and Polkowski, Gregory G and Martin, J Ryan},
title = {Primarily Constraining Custom Triflange Patients: Weighing the Risks of Instability Versus Fixation?},
journal = {The Journal of Arthroplasty},
year = {2025},
doi = {10.1016/j.arth.2024.08.040}
}
EUVIMED