EUVIMEDEUVIMED entdecken
Crossref

Lower Associated Risk of Revision With All-Polyethylene Tibial Components in Total Knee Arthroplasty: An Analysis of the American Joint Replacement Registry

Ryland Kagan, John Andrawis, Jamil Kendall, Ayushmita De, Kyle Mullen, Adam A Sassoon

The Journal of Arthroplasty · 2025

DOI: 10.1016/j.arth.2024.06.060 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2025. Verfasst von Ryland Kagan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Rehabilitation, Oregon Health & Science University, Portland, Oregon. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Reoperation, Registries, Knee Prosthesis. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 13 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Despite the potential advantage of all-polyethylene tibial components, modular metal-backed component use predominates the market in the United States for total knee arthroplasty (TKA). This is partially driven by concerns about the associated revision risk due to the lack of modularity with all-polyethylene components. This study utilized the American Joint Replacement Registry to compare the associated risk of all-cause revision and revision for infection for all-polyethylene versus modular metal-backed tibial components. METHODS: An analysis of primary TKA cases in patients aged 65 years and older was performed with American Joint Replacement Registry data linked to Centers for Medicare and Medicaid Services data from 2012 to 2019. Analyses compared all-polyethylene to modular metal-backed tibial components. We identified 485,024 primary TKA cases, consisting of 479,465 (98.9%) metal-backed and 5,559 (1.1%) all-polyethylene. Cox proportional hazard regression analyses created hazard ratios (HRs) to evaluate the association of design and the risk of all-cause revision while adjusting for sex, age, and the competing risk of mortality. Event-free survival curves evaluate time to revision. RESULTS: The all-polyethylene tibia group demonstrated a decreased risk for all-cause revision (HR = 0.37; 95% confidence interval: 0.24 to 0.55; P < .0001) and revision for infection (HR = 0.41; 95% confidence interval: 0.22 to 0.77, P < .0001). Event-free survival curves demonstrated a decreased risk of all-cause revision that persisted across time points until 8 years post-TKA. CONCLUSIONS: In the United States, all-polyethylene tibial component use for TKA remains low compared to modular metal-backed designs. A decreased associated risk for revision should ease concerns about the use of all-polyethylene components in patients aged 65 years or older, and future investigations should investigate the potential cost and value savings associated with expanded use in this population. LEVEL OF EVIDENCE: Therapeutic Level III.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeReoperationRegistriesKnee ProsthesisPolyethyleneProsthesis FailureProsthesis DesignHumansAgedFemaleMaleUnited StatesAged, 80 and overTibia

Stichwörter der Autor:innen

American Joint Replacement RegistryArthroplasty Registryall-polyethylene tibiarevisiontotal knee arthroplasty

Substanzen

Polyethylene

Autor:innen und Institutionen

  • Department of Orthopaedics and Rehabilitation, Oregon Health & Science University, Portland, Oregon.
  • Department of Orthopaedics, Harbor - University of California Medical Center, Torrance, California.
  • American Academy of Orthopaedic Surgeons, Registries and Data Science Department, Rosemont, Illinois.
  • Department of Orthopaedic Surgery, University of California Los Angeles Medical Center, Santa Monica, California.

Zitieren

APA

Kagan, R., Andrawis, J., Kendall, J., De, A., Mullen, K., & Sassoon, A. A. (2025). Lower Associated Risk of Revision With All-Polyethylene Tibial Components in Total Knee Arthroplasty: An Analysis of the American Joint Replacement Registry. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2024.06.060

Vancouver

Kagan R, Andrawis J, Kendall J, De A, Mullen K, Sassoon AA. Lower Associated Risk of Revision With All-Polyethylene Tibial Components in Total Knee Arthroplasty: An Analysis of the American Joint Replacement Registry. The Journal of Arthroplasty. 2025. doi:10.1016/j.arth.2024.06.060

BibTeX
@article{Kagan2025,
  author = {Kagan, Ryland and Andrawis, John and Kendall, Jamil and De, Ayushmita and Mullen, Kyle and Sassoon, Adam A},
  title = {Lower Associated Risk of Revision With All-Polyethylene Tibial Components in Total Knee Arthroplasty: An Analysis of the American Joint Replacement Registry},
  journal = {The Journal of Arthroplasty},
  year = {2025},
  doi = {10.1016/j.arth.2024.06.060}
}
Kostenlos starten →