Clinical Outcomes of Isolated Polyethylene Exchange Versus Full Component Revision for the Management of Instability Following Total Knee Arthroplasty
The Journal of Arthroplasty · 2024-08 · 39 (8) · S270-S274
DOI: 10.1016/j.arth.2024.04.023 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Arthroplasty, 2024-08. Verfasst von Ryan Cheng und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, New York. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Reoperation, Joint Instability, Polyethylene. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 25 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Instability following total knee arthroplasty (TKA) is a common cause for revision. Isolated polyethylene exchange (IPE) can be performed to increase knee joint stability, but results have been mixed. The purpose of this study was to compare the survivorship and patient-reported outcomes of patients undergoing revision TKA for instability with IPE versus full component revision. METHODS: We reviewed 280 primary TKAs undergoing revision TKA for instability. There were 181 knees that underwent revision with IPE, compared to 99 knees treated with full component revision. The mean follow-up was 32.8 months (range, 24.8 to 82.5). Patient demographics, radiographic parameters, prosthesis constraints, reoperations for instability, and patient-reported outcomes were compared. RESULTS: The survivorship for instability was significantly higher at 2 years (99 versus 92%, P = .024) and 5 years (94 versus 84%, P = .024) for patients undergoing full component revision. Although there was no difference in Knee Injury and Osteoarthritis Outcome Score for Joint Replacements and Veterans RAND 12 physical component scores between the 2 groups at 6 weeks, 1 year, and 2 years after surgery, full revision patients reported greater pain relief (P = .006) and greater improvements in Veterans RAND 12 physical component scores (P = .027) at 1 year and Knee Injury and Osteoarthritis Outcome Score for Joint Replacements scores at 2 years (P = .017) compared to IPE patients. Men were associated with an increased risk for recurrent instability following IPE (hazard ratio 3.3, 95% confidence interval: [1.0 to 10.6]). CONCLUSIONS: Isolated polyethylene exchange was not as reliable or durable compared to full component revision for the management of postoperative instability. These procedures should only be reserved in cases with competent collaterals and when component position, offset, and rotation are optimized.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, New York.
Zitieren
APA
Cheng, R., Debbi, E. M., Chalmers, B. P., Chiu, Y. F., Rodriguez, J. A., & Lee, G. C. (2024). Clinical Outcomes of Isolated Polyethylene Exchange Versus Full Component Revision for the Management of Instability Following Total Knee Arthroplasty. The Journal of Arthroplasty, 39(8), S270-S274. https://doi.org/10.1016/j.arth.2024.04.023
Vancouver
Cheng R, Debbi EM, Chalmers BP, Chiu YF, Rodriguez JA, Lee GC. Clinical Outcomes of Isolated Polyethylene Exchange Versus Full Component Revision for the Management of Instability Following Total Knee Arthroplasty. The Journal of Arthroplasty. 2024;39(8):S270-S274. doi:10.1016/j.arth.2024.04.023
BibTeX
@article{Cheng2024,
author = {Cheng, Ryan and Debbi, Eytan M and Chalmers, Brian P and Chiu, Yu-Fen and Rodriguez, Jose A and Lee, Gwo-Chin},
title = {Clinical Outcomes of Isolated Polyethylene Exchange Versus Full Component Revision for the Management of Instability Following Total Knee Arthroplasty},
journal = {The Journal of Arthroplasty},
year = {2024},
volume = {39},
number = {8},
pages = {S270--S274},
doi = {10.1016/j.arth.2024.04.023}
}
EUVIMED